PCB Piezotronics EX682A40 Скачать руководство пользователя страница 2

 

 

 

The information contained in this document supersedes all similar information that 
may be found elsewhere in this manual. 

  

 

Total  Customer  Satisfaction 

–  PCB 

Piezotronics guarantees Total Customer 
Satisfaction.  If,  at  any  time,  for  any 
reason, you are not completely satisfied 
with  any  PCB  product,  PCB  will  repair, 
replace,  or  exchange  it  at  no  charge. 
You  may  also  choose  to  have  your 
purchase  price  refunded  in  lieu  of  the 
repair,  replacement,  or  exchange  of the 
product.    
 

Service 

–  Due  to  the  sophisticated 

nature  of  the  sensors  and  associated 
instrumentation 

provided 

by 

PCB 

Piezotronics,  user  servicing  or  repair  is 
not  recommended  and,  if  attempted, 
may  void  the  factory  warranty.  Routine 
maintenance,  such  as  the  cleaning  of 
electrical  connectors,  housings,  and 
mounting  surfaces  with  solutions  and 
techniques  that  will  not  harm  the 
physical  material  of  construction,  is 
acceptable. Caution should be observed 
to insure that liquids are not permitted to 
migrate  into  devices  that  are  not 
hermetically 

sealed. 

Such 

devices 

should  only  be  wiped  with  a  dampened 
cloth  and  never  submerged  or  have 
liquids poured upon them.   
 

Repair 

–  In  the  event  that  equipment 

becomes 

damaged 

or 

ceases 

to 

operate,  arrangements  should  be  made 
to  return  the  equipment  to  PCB 
Piezotronics for repair. User servicing or 
repair  is  not  recommended  and,  if 
attempted, 

may 

void 

the 

factory 

warranty.     
 

Calibration 

–  Routine  calibration  of 

sensors  and  associated  instrumentation 
is  recommended  as  this  helps  build 
confidence  in  measurement  accuracy 
and 

acquired 

data. 

Equipment 

calibration 

cycles 

are 

typically 

established  by  the  users  own  quality 
regimen.  When  in  doubt  about  a 
calibration cycle, a good 

“rule of thumb” 

is to recalibrate on an annual basis. It is 
also  good  practice  to  recalibrate  after 
exposure  to  any  severe  temperature 
extreme, 

shock, 

load, 

or 

other 

environmental  influence,  or  prior  to  any 
critical test.  
 
PCB  Piezotronics  maintains  an  ISO- 
9001  certified  metrology  laboratory  and 
offers  calibration  services,  which  are 
accredited  by  A2LA  to  ISO/IEC  17025, 
with  full  traceability  to  SI  through 
N.I.S.T.  In  addition  to  the  normally 
supplied  calibration,  special  testing  is 
also  available,  such  as:  sensitivity  at 
elevated  or  cryogenic  temperatures, 
phase  response,  extended  high  or  low 
frequency  response,  extended  range, 
leak 

testing, 

hydrostatic 

pressure 

testing,  and  others.  For  information  on 
standard 

recalibration 

services 

or 

special  testing,  contact  your  local  PCB 
Piezotronics 

distributor, 

sales 

representative,  or  factory  customer 
service representative.   
 

Returning  Equipment 

– 

Following 

these  procedures  will  insure  that  your 
returned  materials  are  handled  in  the 
most 

expedient 

manner

Before 

Warranty, Service, Repair, and 
Return Policies and Instructions 

Содержание EX682A40

Страница 1: ... CHARGE AMPLIFIER Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E mail info pcb com Web www pcb com ...

Страница 2: ... repair User servicing or repair is not recommended and if attempted may void the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps build confidence in measurement accuracy and acquired data Equipment calibration cycles are typically established by the users own quality regimen When in doubt about a calibration cycle a good rule...

Страница 3: ...ory customer service representative Warranty All equipment and repair services provided by PCB Piezotronics Inc are covered by a limited warranty against defective material and workmanship for a period of one year from date of original purchase Contact PCB for a complete statement of our warranty Expendable items such as batteries and mounting hardware are not covered by warranty Mechanical damage...

Страница 4: ... O PCB板 X O O O O O 电气连接器 O O O O O O 压电晶体 X O O O O O 环氧 O O O O O O 铁氟龙 O O O O O O 电子 O O O O O O 厚膜基板 O O X O O O 电线 O O O O O O 电缆 X O O O O O 塑料 O O O O O O 焊接 X O O O O O 铜合金 黄铜 X O O O O O 本表格依据 SJ T 11364 的规定编制 O 表示该有害物质在该部件所有均质材料中的含量均在 GB T 26572 规定的限量要求以下 X 表示该有害物质至少在该部件的某一均质材料中的含量超出 GB T 26572 规定的限量要求 铅是欧洲RoHS指令2011 65 EU附件三和附件四目前由于允许的豁免 CHINA RoHS COMPLIANCE ...

Страница 5: ...te O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement of GB T 26572 X Indicates that said hazardous substance contained in at le...

Страница 6: ...odel EX682 Series Differential Charge Amplifier Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800 959 4IMI MANUAL NUMBER 55855 MANUAL REVISION C ECN NUMBER 44350 ...

Страница 7: ...R MACHINE CONDITION MONITORING Table of Contents Introduction Page 3 General Features Installation and Wiring Page 3 5 ESD Sensitivity Page 6 Warranty Servicing Warranty Service Return Procedure Page 7 Customer Service Page 8 PAGE 2 ...

Страница 8: ... General Features Din Rail Mount Removable Terminal Blocks for easy wiring 35mm 1 38in Din Rail Mount configuration Space saving 22 5mm 0 9in wide design Installation and Wiring Installation The EX682 Series is designed to be mounted on a 35mm Din Rail Do not install in a harsh area where it can be exposed to cleaning fluids or machine oils The unit should be mounted in a NEMA type enclosure to pr...

Страница 9: ...t leave excess uninsulated wire which can short to adjacent wiring Re install the terminal block This easy to assemble connection method allows devices to be exchanged easily and the electrical connection to be visibly isolated Pin Descriptions Pin 5 Sig Negative Charge Input Signal Pin 6 Shield Common This pin connects shield to Pin 12 Pin 7 Shield Rail This pin connects to the Din Rail bar that ...

Страница 10: ...sonnel This product is intended for use by qualified personnel who recognize shock hazards and are familiar with the safety precautions required to avoid injury Warning 2 ESD sensitivity This equipment is designed with user safety in mind however the protection provided by the equipment may be impaired if the equipment is used in a manner not specified by PCB Piezotronics Inc Caution 1 ESD sensiti...

Страница 11: ...itivity ESD considerations should be made prior to performing any internal adjustments on the equipment Any piece of electronic equipment is vulnerable to ESD when opened for adjustments Internal adjustments should therefore be done ONLY at an ESD safe work area Many products have ESD protection but the level of protection may be exceeded by extremely high voltage Warranty IMI instrumentation is w...

Страница 12: ...xpedite returned instrumentation contact a factory IMI applications engineer for a RETURN MATERIAL AUTHORIZATION RMA NUMBER Please have information available such as model and serial number Also to insure efficient service provide a written description of the symptoms and problems with the equipment to a local sales representative or distributor or contact IMI if none are located in your area Cust...

Страница 13: ... refunded IMI offers to all customers at no charge 24 hour phone support This service makes product or application support available to our customers day or night seven days a week When unforeseen problems or emergency situations arise call the IMI Hot Line at 716 684 0003 and an application specialist will assist you 3425 Walden Avenue Depew NY 14043 2495 Phone 716 684 0003 USA Fax 716 684 3823 I...

Страница 14: ...62912 REV NR ECO 44160 11 24 15 ...

Страница 15: ...62912 REV NR ECO 44160 11 24 15 ...

Страница 16: ...62912 REV NR ECO 44160 11 24 15 ...

Страница 17: ...62912 REV NR ECO 44160 11 24 15 ...

Страница 18: ...62912 REV NR ECO 44160 11 24 15 ...

Страница 19: ...62912 REV NR ECO 44160 11 24 15 ...

Страница 20: ...ise 10 Hz 15 µV Hz 15 µV Hz 1 Spectral Noise 100 Hz 5 µV Hz 5 µV Hz 1 Spectral Noise 1 kHz 2 µV Hz 2 µV Hz 1 Spectral Noise 10 kHz 2 µV Hz 2 µV Hz 1 Discharge Time Constant 0 25 sec 0 25 sec Resistance 50 000 Ohm 50 000 Ohm Source Capacitance Loading 0 0003 pF 0 0003 pF Output in Relation to Input In Phase In Phase Physical Electrical Connector Input Terminal Strip Terminal Strip Electrical Connec...

Страница 21: ......

Страница 22: ...IIC T4 Pour l usage sûr Toutes lois électriques locales et applicables doivent être suivies La provision les paramètres électriques ne doivent pas dépasser n importe quel des valeurs suivantes o Ui 28V Ii 100mA Pi 0 7 W Ci 0nF Li 0uH Uo 28V Io 60mA Po 0 42 W Co 83 nF Lo 10uH La gamme de température d opération Ambiante o 40 C Ta 85 C Italiano Questo sensore è stato approvato per le Posizioni Peric...

Страница 23: ...gekeurd worden Ex ia IIC T4 Voor veilige gebruik Alle toepasbare plaatselijke elektrische wetten moeten gevolgd worden De aanbod elektrische parameters moeten de volgende waarde niet overschrijden o Ui 28V Ii 100mA Pi 0 7 W Ci 0nF Li 0uH Uo 28V Io 60mA Po 0 42 W Co 83 nF Lo 10uH Het omgevend bediening temperatuur bereik o 40 C Ta 85 C Português Este sensor foi aprovado para a Diretiva 94 9 EC de P...

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ... Control and Laboratory Use EMC Electrical Equipment for Measurement Control and Laboratory Use EMC Safety Standard General Explosive Atmosphere Intrinsic safe General Explosive Atmosphere Intrinsic safe Emissions Test standards EN 2007 Industrial scientific and medical SM radio frequency equipment Electromagnetic disturbance characteristics Limits and methods of Measurement Class B Immunity Test ...

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ......

Страница 33: ......

Страница 34: ...ardous Locations CLASS 2258 83 PROCESS CONTROL EQUIPMENT Intrinsically Safe and Non Incendive Systems For Hazardous Locations Certified to U S Standards Class I Division 1 Groups A B C and D Model EX682XYYYY Differential Charge Amplifier input rated 28 Vdc max 20 mA max intrinsically safe with entity parameters at Power terminals VDC COM Vmax Ui 28V Imax Ii 100mA Pi 0 7 W Li 10 8 uH Ci 0 nF Sensor...

Страница 35: ...jurisdiction The Model EX682XYYYY shall only be connected to non incendive Certified equipment per installation drawing APPLICABLE REQUIREMENTS CAN CSA C22 2 No 0 2010 General Requirements Canadian Electrical Code Part II C22 2 No 142 M1987 R2009 Process Control Equipment CAN CSA C22 2 No 157 92 R2012 Intrinsically Safe and Non Incendive Equipment for Use in Hazardous Locations C22 2 No 213 M1987 ...

Отзывы: