![Paxton Switch2 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/paxton/switch2/switch2_installation-manual_1513401020.webp)
Door open time
The door open time will be set to 7 seconds as default. This is the time the relay will stay
activated for once either a correct code is entered or an exit button has been pressed.
The time can be changed to suit the situation and can be set to anything from 1 to 60
seconds.
Remote button
An exit/remote button can be connected to Switch2. It can be set-up to work in one of
two ways. The button can be programmed to open the door for the door open time. This
is set as default. The button can also be programmed to toggle the relay. This second
option will change the door condition to the opposite of its current condition every time
the button is pressed.
Data resetting the keypad
The Switch2 control unit can be reset to the default conditions below. It can either be
reset from the keypad by following the programming guide or by following the procedure
below.
Default Settings
User code
1 2 3 4
Master code
Set by installer when unit is initialised
Code mode
Single
Squeak setting
Activated
Door open time
7 seconds
Remote button
Switch relay for door open time
Lockout mode
Lockout disabled