17
746
Lock tag fail. The RFID tag has not been locked to prevent
reprogramming. This is considered a bad RFID tag. For more
information, refer to the
RFIDMP Application Notes
or the
HF Application
Notes
.
747
Time out failure. An RFID command (read, program, etc.) has failed to
complete in the maximum amount of allowed time.
748
Invalid data length/data mismatch from RFID interrogator module. The
RFID interrogator module found a problem with the data received from
the printer. For more information, refer to the
RFIDMP Application Notes
or the
HF Application Notes
.
749
RFID Verify Fail. The RFID verification process failed after writing
(programming) tag. This is considered a bad RFID tag. For more
information, refer to the
RFIDMP Application Notes
or the
HF Application
Notes
.
751
Printer did not sense a black mark when expected. Press Escape/Clear
and try to continue printing. Change supply.
752
Printer sensed a mark in the wrong place.
753
Printer sensed a mark that is too long.
754
Check for a ribbon jam or remove any slack in the ribbon by turning the
take-up reel clockwise. Load a new ribbon.
755
Printhead is open. Close the printhead.
756
Load supplies.
757
Load supplies (supply length mismatch). Press Feed/Cut.
758
Either the supply is not seen, the on-demand sensor is broken, or a label
was removed too quickly. Check for a label jam or reload supplies.
763
Waiting to dispense label. Press Feed/Cut.
765
The printhead has less than 8 bad dots and can shift bar code fields to
avoid bad dots. Press Escape/Clear to continue printing.
768
Printhead has more than 8 bad dots within the format area or is not
connected. Replace or connect printhead as necessary.
The printer does
not
recalibrate (feed a blank label) after any RFID error. Refer to
the
RFIDMP Application Notes
or the
HF Application Notes
(on our Web site) for
more information.