en
8
2.4
SD memory card slot
The controller is equipped with an SD card slot.
With an SD card, the following functions can be carried out:
• Store measurement and balance values onto the SD
card. After the transfer to a computer, the values can be
opened and visualised, e. g. in a spreadsheet.
• Prepare adjustments and parameterisations on a computer
and transfer them via the SD card.
• Store adjustments and parameterisations on the SD card
and, if necessary, retrieve them from there.
• Download fi rmware updates from the Internet and install
them on the controller.
For more information about using an SD card, see page 65.
3
Step-by-step parameterisation
The SC5.14 controller is a controller that offers a broad variety of functions to the
user. At the same time, the user has a lot of freedom in confi guring them. Therefore,
to set up a complex system, careful planning is required. We recommend drawing
a sketch of the system fi rst.
If planning, hydraulic execution and electrical connection have all been carried out
successfully, proceed as follows:
1. Running the commissioning menu
The commissioning menu is run after the fi rst connection and after every reset. It
will request the following basic adjustments:
• Menu language
• Temperature unit
• Volume unit
• Pressure unit
• Energy unit
• Time
• Date
• Solar system
• Hydraulic variant
At the end of the commissioning menu, a safety enquiry follows. If the safety en-
quiry is confi rmed, the adjustments will be saved.
For further information about the commissioning menu see page 13.
2. Registering sensors
If fl owmeters, fl ow switches, Grundfos Direct Sensors™ and/or external extension
modules are connected, these have to be registered in the In-/Outputs menu.
For further information about the registration of modules and sensors see page 67.
3. Activating solar optional functions
The basic solar system has been adjusted during commissioning. Now, optional
functions can be selected, activated and adjusted.
Free relays can be allocated to optional functions which require a relay. The con-
troller always suggests the numerically smallest free relay.
Sensors can be allocated to more than one function.
For further information about the optional arrangement functions see page 33.
4. Activating optional arrangement functions
Now, optional functions for the non-solar part of the arrangement can be selected,
activated and adjusted.
Free relays can be allocated to optional functions which require a relay. The con-
troller always suggests the numerically smallest free relay.
Sensors can be allocated to more than one function.
For further information about the optional arrangement functions see page 46.
5. Adjusting heating circuits and activating optional heating functions
Now, heating circuits can be activated and adjusted.
For the heating part of the arrangement, optional functions can be selected, acti-
vated and adjusted.
To heating circuits and optional functions which require one or more relays, the
corresponding number of free relays can be allocated. The controller always sug-
gests the numerically smallest free relay.
Sensors can be allocated to more than one function.
For further information about heating circuits and optional heating functions see
page 56.