27
System Functions
EN
A1 / A2 / A3 / A4
Malfunction temperature sensor
T1 / T2 / T3 / T4
Isolate from mains supply
Remove filters,
plastic front
and sealing plate
Yes
No
Replace PCB
ATTENTION: Reset unit
WARNING!
Danger of death from
live components –
do not touch the PCB!
Resistance [KΩ]
[°C]
MIN.
MED.
MAX.
10
19.570
19.904
20.242
15
15.485
15.712
15.941
18
13.502
13.681
13.861
19
12.906
13.071
13.237
20
12.339
12.491
12.644
21
11.801
11.941
12.082
22
11.291
11.420
11.550
25
9.900
10.000
10.100
30
7.959
8.057
8.155
Remove the temperature sensor
from PCB
Check resistance of
temperature sensor;
refer to table
Resistance OK?
Replace
temperature sensor
Temperature
E4
santos turned off
via an external contact
Cause lies with unit
connected to santos:
check the connected unit.
WARNING!
Danger of death from
live components –
do not touch the PCB!
5
Malfunction
temperature sensor
Tghe
Isolate from mains supply
Check resistance
of temperature sensor;
refer to table
Resistance OK?
Yes
No
Isolate from mains supply!
Replace PCB
ATTENTION:
Reset unit
Isolate from
mains supply!
Replace
temperature sensor
WARNING!
Danger of death from
live components –
do not touch the PCB!
A0
Содержание santos 570 DC
Страница 17: ...13 System Functions EN 3 3 Dimension Sketch ...
Страница 42: ...38 EN ...
Страница 43: ...39 EN ...
Страница 44: ...849050687 0510 EN ...