M
MO
OD
DE
ES
S O
OFF O
OP
PE
ER
RA
ATTIIO
ON
N
1 2
ON
AM
PM
OFF
Thermostatic Mode
The room temperature is measured and
compared to the set temperature. The
flame height is then automatically ad-
justed to achieve the set temperature.
1 2
ON
AM
PM
OFF
Program Mode
PROGRAMS 1 and 2, each can be pro-
grammed to go ON and OFF at specific
times at a set temperature.
AM
Eco Mode
Flame height modulates between high
and low. If the room temperature is low-
er than the set temperature, the flame
height stays on high for a longer period
of time. If the room temperature is high-
er than the set temperature, the flame
height stays on low for a longer period
of time. One cycle lasts approx. 20 min.
TTH
HE
ER
RM
MO
OS
STTA
ATTIIC
C M
MO
OD
DE
E
1 2
ON
AM
PM
OFF
ON:
Press button. displayed, preset tem-
perature displayed briefly, and then room
temperature displayed.
OFF:
1. Press button.
2. Press or button to enter Manual
Mode.
3. Press button to enter Program Mode.
4. Press button to enter Eco Mode.
1 2
ON
AM
PM
OFF
SETTING:
1. Press
button and hold until dis-
played, temperature flashes.
2. To adjust set temperature press or
button.
3. To confirm press button or wait.
P
PR
RO
OG
GR
RA
AM
M M
MO
OD
DE
E
1 2
ON
AM
PM
OFF
ON:
Press button. , or ,
or
displayed.
1 2
ON
AM
PM
OFF
OFF:
1. Press or
or button to enter
Manual Mode.
2. Press button to enter Thermostatic
Mode.
NOTE:
The set temperature for Thermostatic Mode is the tem-
perature for the ON time in Program Mode. Changing
the Thermostatic Mode set temperature also changes
the ON time temperature in Program Mode.
Default settings:
ON TIME (Thermostatic) TEMPERATURE: 70 °F / 21 °C
OFF TIME TEMPERATURE: “
” (pilot flame only)
1 2
ON
AM
PM
OFF
TEMPERATURE SETTING:
1. Press button and hold until
flashes.
and set temperature (set-
ting in Thermostatic Mode) displayed.
2. To continue press button or wait.
,
displayed, temperature flash-
es.
3. Select OFF temperature by pressing
the or button.
4. To confirm press button.
NOTE:
The ON (Thermostatic) and OFF set temperatures are
the same for each day.
1 2
ON
AM
PM
OFF
DAY SETTING:
5.
flashes. Press or button to
choose between
,
, , , , ,
, , .
6. To confirm press button.
REMOTE CONTROL INSTALLATION
87.
Aerion Range
Содержание Aerion Series
Страница 7: ...PRODUCT DIMENSIONS 2 G1410 GF G1410 GF2L Aerion Range...
Страница 8: ...PRODUCT DIMENSIONS 3 G1410 GF2R GF1410 GF3 Aerion Range...
Страница 9: ...PRODUCT DIMENSIONS 4 G1410 RD G1410 T Aerion Range...
Страница 10: ...PRODUCT DIMENSIONS 5 G1250 GF GF1250 GF2L Aerion Range...
Страница 12: ...PRODUCT DIMENSIONS 7 G800 GF G800 T Aerion Range...
Страница 13: ...PRODUCT DIMENSIONS 8 G650 Aerion Range ALTO GF...
Страница 14: ...PRODUCT DIMENSIONS 9 ALTO T Aerion Range...
Страница 22: ...17 Aerion Range UNIT TO TV CLEARANCES COMBUSTIBLE MANTLE Figure 1 4 Clearance from Unit to TV...
Страница 104: ...Distributed By LIVING FIRE 61 3 99 777 888 info livingfire com au www livingfire com au...