background image

SmartNode 2290 Series

Leased-Line Extenders over IP

User Manual

Sales Office:

 

+1 (301) 975-1000

Technical Support:

 

+1 (301) 975-1007

E-mail:

 

[email protected]

WWW:

 

www.patton.com

Part Number: 

07M2292-GS, Rev. B

Revised: 

February 9, 2012

Содержание SmartNode 2290 Series

Страница 1: ...290 Series Leased Line Extenders over IP User Manual Sales Office 1 301 975 1000 Technical Support 1 301 975 1007 E mail support patton com WWW www patton com Part Number 07M2292 GS Rev B Revised Febr...

Страница 2: ...of such license Patton Electronics warrants all SmartNode extender components to be free from defects and will at our option repair or replace the product should it fail within one year from the firs...

Страница 3: ...tions overview 18 3 Hardware installation 20 4 Getting started with the SmartNode 31 5 LEDs status and monitoring 35 6 Contacting Patton for assistance 37 A Compliance information 40 B Specifications...

Страница 4: ...e installation 20 Planning the installation 21 Installation checklist 22 Site log 23 Network information 23 IP related information 23 Software tools 23 Power source 23 Location and mounting requiremen...

Страница 5: ...acity 43 Audio connectivity 43 Data Services 43 Quality of Service 43 Voice Signaling 43 Voice Processing 44 Management 44 System 44 Temperature 44 Humidity 44 C Cabling 45 Introduction 46 Serial cons...

Страница 6: ...8 Analog connection 26 9 RJ 11 pinout diagram 26 10 Connecting a SmartNode 2294 Series device to a hub 27 11 Connecting to a host 28 12 Power connector location on rear panel 29 13 SmartNode extender...

Страница 7: ...list 22 4 Sample site log entries 23 5 RJ 11 socket 26 6 Ethernet 10 100Base T RJ 45 port pin outs SmartNode 2294 Series 27 7 Factory default IP address and network mask configuration 33 8 SmartNode L...

Страница 8: ...n and applications Chapter 3 on page 20 provides quick start hardware installation procedures Chapter 4 on page 31 describes getting started with the SmartNode extender Chapter 5 on page 35 contains d...

Страница 9: ...G heading indicate a potential electric shock hazard Strictly follow the warning instructions to avoid injury caused by electric shock The alert symbol and WARNING heading indicate a potential safety...

Страница 10: ...he mains outlet that is utilized to power the devise shall be within 10 feet 3 meters of the device shall be easily accessible and pro tected by a circuit breaker Hazardous network voltages are presen...

Страница 11: ...ds Electrostatic Discharge ESD can damage equipment and impair electrical circuitry It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermit tent f...

Страница 12: ...ic type Parts of commands which are related to elements already named by the user are in boldface italic font Italicized Futura type Variables for which you supply values are in italic font Futura typ...

Страница 13: ...13 Chapter 1 General information Chapter contents SmartNode Series Leased Line Extenders overview 14 SmartNode 2292 and 2294 Leased Line Extenders 15 Ports descriptions 16 Reset button behavior 16...

Страница 14: ...data connectivity Figure 1 SmartNode extender SmartNode 2294 shown The SmartNode 2292 and 2294 Leased Line Extenders equipped with two 10 100Base T Ethernet ports pro vide voice over IP VoIP and Inter...

Страница 15: ...2 EUI 2 VoIP leased line channels SmartNode 2294 EUI 4 VoIP leased line channels The port combinations are indicated in the extension of the model code T he following model code conven tions apply The...

Страница 16: ...ear panel ports Port Location Description 10 100 Ethernet ETH 0 0 ETH 0 1 Rear panel RJ 45 connectors see figure 6 on page 25 that connect the extender to an Ethernet device e g a cable or DSL modem L...

Страница 17: ...rtNode 2292 and 2294 front panels Note For LED descriptions refer to chapter 5 LEDs status and monitor ing on page 35 Model 2294 Link 100M Activity 0 0 0 1 Enet 0 Ports Power Console Leased Line Exten...

Страница 18: ...18 Chapter 2 Applications overview Chapter contents Typical application 19 Leased line extension 19...

Страница 19: ...lines can be transported over a packet based network This essentially ensures that with just Internet access at two locations four leased lines between these two locations can be established Combine...

Страница 20: ...etwork Diagram 23 IP related information 23 Software tools 23 Power source 23 Location and mounting requirements 24 Installing the SmartNode extender 24 Mounting the SmartNode extender 24 Connecting c...

Страница 21: ...y the applicable local and international regulations Ensure that your site is prop erly prepared before beginning installation Before installing the SmartNode extender device the following tasks shoul...

Страница 22: ...st in your site log Table 3 Installation checklist Task Verified by Date Network information available recorded in site log Environmental specifications verified Site power voltages verified Installat...

Страница 23: ...t LAN and WAN ports IP addresses of central H 323 Gatekeeper if used IP addresses of central PSTN Gateway for H 323 and or ISoIP based calls IP addresses of central TFTP Server used for configuration...

Страница 24: ...rtNode extender Place the extender on a desktop or similar sturdy flat surface that offers easy access to the cables The extender should be installed in a dry environment with sufficient space to allo...

Страница 25: ...extender The voice ports are connected to analog devices via cables see figure 7 terminated with RJ 11 connectors see figure 9 and table 5 on page 26 for pin out information Figure 6 Rear view showing...

Страница 26: ...diagram Note Unit must not connect directly to telecom network voltage TNV Table 5 RJ 11 socket Pin Signal 3 Ring 4 Tip RJ 11 male RJ 11 male PSTN wall plate 1 25A Reset Ports ETH 0 1 ETH 0 0 Socket...

Страница 27: ...d to the SmartNode s Ethernet ports see table 6 for port pin out listing via a cable terminated with RJ 45 plugs Because the Smart Node 2294 Series does not have the MDX feature a cross over cable is...

Страница 28: ...28 SmartNode 2290 Series User Manual 3 Hardware installation Figure 11 Connecting to a host Host Cross over cable RJ 45 male Tx Tx Rx Rx 1 2 3 6 RJ 45 1 TX 2 TX 3 RX 6 RX Twisted pair 1 Twisted pair 2...

Страница 29: ...anel 2 Verify that the AC power cord included with your extender is compatible with local standards If it is not refer to Contacting Patton for assistance on page 37 to find out how to replace it with...

Страница 30: ...r 4 Getting started with the SmartNode on page 31 Console port Power VoIP Link Enet 0 Link Run Enet 0 Activity Enet 0 100M Enet 1 Link Enet 1 100M Enet 1 Activity Voice Port 0 0 Voice Port 0 1 Voice P...

Страница 31: ...31 Chapter 4 Getting started with the SmartNode Chapter contents Introduction 32 Configure the IP address 33 Power connection and default configuration 33 Connect with the serial interface 33 Login 34...

Страница 32: ...3 Load configuration Console port Serial interface PC or workstation with VT 100 emulation terminal Ethernet interface ETH0 PC or workstation or VT 100 emulation terminal 2 Modify configuration Intern...

Страница 33: ...nd cable see figure 15 between the SmartNode s Console port and a PC or workstation s RS 232 serial interface Activate the terminal emulation program on the PC or workstation that supports the serial...

Страница 34: ...e pair Copy nvram a side config startup config Copy running config startup config 4 Follow the same procedure for the other SmartNode 229x device in the pair Copy nvram b side config startup config Co...

Страница 35: ...35 Chapter 5 LEDs status and monitoring Chapter contents Status LEDs 36...

Страница 36: ...IP connection Off indicates the unit is not configured or registered and has no active VoIP connection Flashing green indicates that the unit is attempting or has failed to associate register Voice po...

Страница 37: ...r contents Introduction 38 Contact information 38 Warranty Service and Returned Merchandise Authorizations RMAs 38 Warranty coverage 38 Out of warranty service 38 Returns for credit 38 Return for cred...

Страница 38: ...re ship ment All of our products are backed by a comprehensive warranty program Note If you purchased your equipment from a Patton Electronics reseller ask your reseller how you should proceed with wa...

Страница 39: ...a request on the RMA Request page in the Support section at www patton com By calling 1 301 975 1007 and speaking to a Technical Support Engineer By sending an e mail to returns patton com All returne...

Страница 40: ...40 Appendix A Compliance information Chapter contents Compliance 41 EMC 41 Safety 41 CE Declaration of Conformity 41...

Страница 41: ...ve 1999 5 EC on the approximation of the laws of the member states relating to Radio and Telecommunication Terminal Equipment and the mutual rec ognition of their conformity The safety advice in the d...

Страница 42: ...ppendix B Specifications Chapter contents Capacity 43 Audio connectivity 43 Data Services 43 Quality of Service 43 Voice Signaling 43 Voice Processing 44 Management 44 System 44 Temperature 44 Humidit...

Страница 43: ...rver Packet fragmentation Static firewall NAT NAPT RFC 1631 access control lists DMZ port IPsec IKE AES DES 3DES Encryption Quality of Service Audio priority DownStreamQoS Traffic management shaping a...

Страница 44: ...TP CLI with local console and remote Telnet access TFTP configuration firmware loading SNMP MIB II and product MIB Secure Mass provisioning for both firmware and unit configuration Built in diagnostic...

Страница 45: ...45 Appendix C Cabling Chapter contents Introduction 46 Serial console 46 Ethernet 10Base T and 100Base T 47 Analog FXS 48...

Страница 46: ...nnected to a serial terminal over its serial console port as depicted in figure 17 Figure 17 Connecting a serial terminal Note See section Console port on page 50 for console port pin outs Serial Term...

Страница 47: ...to a host or a straight cable to a hub See figure 18 host and figure 19 on page 48 hub for the different connections Note The SmartNode 2292 Series is equipped with Auto MDX Ethernet ports Use straigh...

Страница 48: ...d to analog terminals phones fax machines answering machines via cables terminated with RJ 11 connectors see section Voice port on page 50 for details on port pinouts Figure 20 Connecting an FXS devic...

Страница 49: ...49 Appendix D Port pin outs Chapter contents Introduction 50 Console port 50 Ethernet 10Base T and 100Base T port 50 Voice port 50...

Страница 50: ...RJ 45 8 pin port Note Pins not listed are not used Ethernet 10Base T and 100Base T port Note Pins not listed are not used Voice port The voice ports use an RJ 11 connector with 6 positions The midle t...

Страница 51: ...51 Appendix E Installation checklist Chapter contents Introduction 52...

Страница 52: ...og Table 11 Installation checklist Task Verified by Date Network information available recorded in site log Environmental specifications verified Site power voltages verified Installation site pre pow...

Отзывы: