background image

2

SmartNode 10200 Series Quick Start Guide

• Do not open the device when the power cord is connected. For sys-

tems without a power switch and without an external power 
adapter, line voltages are present within the device when the power 
cord is connected.

• For devices with an external power adapter, the power adapter shall 

be a listed 

Limited Power Source

 The mains outlet that is utilized to 

power the device shall be within 10 feet (3 meters) of the device, 
shall be easily accessible, and protected by a circuit breaker in compli-
ance with local regulatory requirements.

• For AC powered devices, ensure that the power cable used meets all 

applicable standards for the country in which it is to be installed.

• For AC powered devices which have 3 conductor power plugs (L1, L2 

& GND or Hot, Neutral & Safety/Protective Ground), the wall outlet 
(or socket) must have an earth ground.

• For DC powered devices, ensure that the interconnecting cables are 

rated for proper voltage, current, anticipated temperature, flammabil-
ity, and mechanical serviceability.

• WAN, LAN & PSTN ports (connections) may have hazardous voltages 

present regardless of whether the device is powered ON or OFF.  
PSTN relates to interfaces such as telephone lines, FXS, FXO, DSL, 
xDSL, T1, E1, ISDN, Voice, etc. These are known as “hazardous net-
work voltages” and to avoid electric shock use caution when working 
near these ports.  When disconnecting cables for these ports, detach 
the far end connection first.

• Do not work on the device or connect or disconnect cables during peri-

ods of lightning activity.

• This device contains no user serviceable parts.  This device can only be 

repaired by qualified service personnel.

• If one has reason to open the chassis or case, then the precautions 

mentioned above shall be followed.  This includes both the warnings 
relating to disconnection of the input power, and the warnings relat-
ing to the disconnection of WAN, LAN & PSTN ports. 

In accordance with the requirements of council directive 2002/96/EC on 
Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-
of-life you separate this product from other waste and scrap and deliver 
to the WEEE collection system in your country for recycling.

This device is NOT intended nor approved for connection to the PSTN. 
It is intended only for connection to customer premise equipment.

WARNING

WARNING

Содержание SmartNode 10200 Series

Страница 1: ...Start Guide Important This is a Class A device and is not intended for use in a residential environment Part Number 07MSN10200 QS Rev D Revised May 7 2012 Sales Office 1 301 975 1000 Technical Suppor...

Страница 2: ...s may have hazardous voltages present regardless of whether the device is powered ON or OFF PSTN relates to interfaces such as telephone lines FXS FXO DSL xDSL T1 E1 ISDN Voice etc These are known as...

Страница 3: ...t Guide One SmartNode 10200 Important Notice sheet with unique information for your specific unit To install the SN10200 you will need not included Two AC power cords 19 equipment rack 2 0 Installing...

Страница 4: ...1 and SMS ports SMS 0 0 0 1 are not used when connecting VoIP Figure 2 Connecting the VoIP ports 4 0 Connecting to the PSTN Network 1 Connect the SN10200 to the PSTN using one of the following option...

Страница 5: ...Dual BNC connectors 4 3 Optical Interface OC3 STM 1 Figure 5 Connecting to the PSTN via the optical interface ETH VoIP SMP 0 0 0 1 0 0 0 1 0 0 0 1 T1 E1 SCSI connectors 49 64 33 48 17 32 1 16 ETH VoIP...

Страница 6: ...t interface see 6 2 Connecting the Ethernet man agement interface on page 7 The IP address of the management port is 192 168 200 10 24 If it is not possible to connect to the management port via IP us...

Страница 7: ...ode using the specific credentials included on the Important Notice sheet that shipped with your unit The management port is configured with a static Class C IP address by default Figure 8 Connecting...

Страница 8: ...thernet management port follow the instructions in 6 2 Connecting the Ethernet management interface on page 7 2 To access the SN10200 you must use an SSH connection The password is set at the factory...

Страница 9: ...ct to the Web Portal by typing the following in your address bar http DEVICE HOST NAME 12358 or alternately http DEVICE IP ADDRESS 12358 8 2 Logging on to the Web Portal In order to log on to the Web...

Страница 10: ...cular installation If the equipment causes interference to radio or television reception which can be determined by disconnecting the cables try to correct the interference by one or more of the follo...

Страница 11: ...nline support www patton com E mail support support patton com answered within 1 business day Telephone support Standard 1 301 975 1007 USA Monday Friday 8 00 am to 5 00 pm EST 1300 to 2200 UTC GMT Al...

Страница 12: ...tton Electronics assumes no liability for errors that may appear in this document Trademarks statement The term SmartNode is a trademark of Patton Electronics Company All other trademarks presented in...

Отзывы: