manualshive.com logo in svg
background image

Introduction

3

SmartNode 4900 Quick Start Guide 

Introduction

This Quick Start Guide leads you through the basic steps to set up a new SmartNode and to download a con-
figuration. Please note that this guide does not replace the detailed 

SmartWare

 

Software Configuration Guide

 

and the 

SmartNode 4900 User Manual 

available online at 

www.patton.com/manuals/SN4900.pdf

.

SmartNodes can be used for a wide variety of IP and voice over IP applications. To support and ease the con-
figuration of the SmartNodes configuration templates for the most important applications are available online 
at 

www.patton.com/voip/appnotes.asp

.

Setting up a new SmartNode consists of the following steps:

1.

Attach the power cable retainer clips to the unit 

2.

Connect a PC to the SmartNode, log in and configure your LAN IP address (see 

page 4

 for details)

3.

Connect the SmartNode to the LAN (see 

page 6

)

4.

Download a configuration example, adapt it to your network, and load it onto the SmartNode (see 

page 7

)

Attaching the cable retainer clips

To secure the power cord, it is necessary to attach the metal retainer clips (if applicable to your model). Squeeze 
the clip and insert into the holes in the screws on either side of the power connector on your unit. The clip will 
pop into place. 

Figure 1. Attaching the cable retainer clips

Note

Refer to the 

SmartNode 4900 User Manual 

on the Patton website for 

detailed instructions about grounding and connecting power to your 
unit. 

For FXO (/JO) models:

 To maintain CE/EMC compliance, 

attach the included snap-on ferrite clamp (Patton P/N 0818S-
02) to the 64/50 pin telco cable (not included but available 
upon request) about four inches away from the FXO box telco 
port connector. 

IMPORTANT

Power cable

retainer clip

Содержание SMARTNODE 4900

Страница 1: ...ick Start Guide Sales Office 1 301 975 1000 Technical Support 1 301 975 1007 E mail support patton com WWW www patton com Part Number 07MSN4900 QS Rev D Revised February 9 2012 Start Installation For Quick Start Installation For Quick ...

Страница 2: ...subject to change without notice Patton Elec tronics assumes no liability for errors that may appear in this document In no event shall Patton Electronics or its employees and associated companies be lia ble for any incidental special indirect or consequential damages whatsoever including but not limited to lost profits arising out of or related to this manual or the informa tion contained within ...

Страница 3: ...Node log in and configure your LAN IP address see page 4 for details 3 Connect the SmartNode to the LAN see page 6 4 Download a configuration example adapt it to your network and load it onto the SmartNode see page 7 Attaching the cable retainer clips To secure the power cord it is necessary to attach the metal retainer clips if applicable to your model Squeeze the clip and insert into the holes i...

Страница 4: ...h an RS 232 console port to the Con sole port on the front of the SmartNode Use the included black Ethernet cable and RJ45 to DB 9 adapter for this purpose Model 16F 561 Figure 2 Connecting to the PC 2 Open a Terminal connection to the SmartNode Use the Terminal program included with most PC oper ating systems e g Hyper Terminal on Windows Table 1 Factory default IP address and network mask config...

Страница 5: ...de to configure an IP interface 172 16 40 1 cfg context ip router 172 16 40 1 ctx ip router 2 Set the IP address and network mask for the each IP interface eth0 for example Note For the examples in this guide a private network 172 16 1 IP address is used 172 16 40 1 ctx ip router interface eth0 172 16 40 1 if ip eth0 ipaddress 172 16 1 10 255 255 255 0 2002 10 29T00 09 40 LOGINFO Link down on inte...

Страница 6: ...the CLI commands but we recommend that you start your configuration from a template See Downloading a configuration example adapting it to your network and loading it onto the SmartNode on page 7 for further details For a detailed description of the CLI refer to the SmartWare Software Configuration Guide SCG available on online at www patton com smartnode 10 0 24 0V 5 0 60 Hz 1 AM P UNI T EQU IPP ...

Страница 7: ...ide for information on configuring the SmartNode device In this example we assume the TFTP server on the host with the IP address 172 16 1 11 and the configuration named SN cfg in the root directory of the TFTP server 172 16 1 99 if ip eth0 copy tftp 172 16 1 11 SN cfg startup config Download 100 172 16 1 99 if ip eth0 After the SmartNode has been rebooted the new startup configuration will be act...

Страница 8: ...ärung see section EC Declaration of Conformity for English version Produktbezeichnung SmartNode 4900 Die bezeichneten Produkte stimmen in der von uns in Verkehr gebrachten Ausführung mit den Vorschriften folgender Richtlinie überein R TTE 1999 5 EG Richtlinie des europäischen Parlaments und des Rates zur Angleichung der Rechtsvorschriften der Mit gliedstaaten über Funkanlagen und Telekommunikation...

Отзывы: