APPENDIX B

PIN CONFIGURATIONS

15

APPENDIX C

BLOCK DIAGRAM

16

1 - (FG) Frame Ground

Common

2 - (TD) Transmit Data

To Model 1035

3 - (RD) Receive Data

From Model 1035

4 - (RTS) Request to Send

To Model 1035

5 - (CTS) Clear to Send

From Model 1035

6 - (DSR) Data Set Ready

From Model 1035

7 - (SG) Signal Ground

Common

8 - (CD) Carrier Detect

From Model 1035

To Model 1035

Data Term. Ready (DTR) - 20

DIRECTION

RS-232 PIN-OUT REFERENCE (DB-25)

DIRECTION

To Model 1035

External Clock - 24

From Model 1035

Transmit Clock - 15   

From Model 1035

Receive Clock - 17

To Model 1035

Local Analog Loopback - 18

From Model 1035 Remote Digital Loopback - 21

From Model 1035

Test Mode - 25

1 - (FG) Frame Ground

Common

2 - Transmit Data A

To Model 1035

3 - Receive Data A

From Model 1035

4 - (RTS) Request to Send

To Model 1035

5 - (CTS) Clear to Send

From Model 1035

6 - (DSR) Data Set Ready

From Model 1035

7 - (SG) Signal Ground

Common

8 - (CD) Carrier Detect

From Model 1035

9 - Receive Clock B

From Model 1035

11 - External Clock B

To Model 1035

12 - Transmit Clock B

From Model 1035

To Model 1035

Data Term. Ready (DTR) - 20

DIRECTION

CCITT V.35 PIN-OUT REFERENCE (DB-25)

DIRECTION

To Model 1035

External Clock A - 24

From Model 1035

Transmit Clock A - 15   

From Model 1035

Receive Clock A - 17

To Model 1035

Local Loopback (LAL) - 18

To Model 1035

Remote Loopback (RDL) - 21

From Model 1035

Test Mode - 25

To Model 1035

Transmit Data B - 14   

From Model 1035

Receive Data B - 16   

1035

Содержание RS-232

Страница 1: ...ER MANUAL MODEL 1035 Powered High Speed Short Range Modem RS 232 and V 35 versions SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1035 A Doc 054071UA Revised 7 6...

Страница 2: ...insured to Patton Electronics All returns must have a Return Materials Authorization number on the outside of the shipping container This number may be obtained from Patton Electronics Technical Servi...

Страница 3: ...structions on opening the Model 1035 case see Section 3 2 Figure 2 shows the orientation of the switches including the ON OFF positions 3 Figure 2 Close up of configuration switches OFF 1 2 3 4 5 6 7...

Страница 4: ...f n a SW1 4 Not Used Off n a SW1 5 Not Used Off n a SW1 6 Not Used Off n a SW1 7 Not Used Off n a SW1 8 V 54 Enable Disable Off Enabled Figure 3 Summary of DIP switch settings for set SW1 SW1 8 V 54 E...

Страница 5: ...35 supports communication between two RS 232 devices or two V 35 devices at distances to 6 miles and data rates to 64 Kbps There are two essential requirements for installing the Model 1035 1 These un...

Страница 6: ...r host A direct connection to the RS 232 or V 35 DTE port is most desirable If you must use a cable to connect the Model 1035 to the DTE port make sure it is a straight through cable of the shortest p...

Страница 7: ...Local Analog Loopback LAL The Local Analog Loopback LAL test checks the operation of the local Model 1035 and is performed separately on each unit Any data sent to the local Model 1035 in this test m...

Страница 8: ...problem with the twisted pair line between the modems You should then check the twisted pair line for proper connections and continuity 5 3 3 Using the V 52 BER Test Independently The V 52 BER test c...

Страница 9: ...l Loopback 21 From Model 1035 Test Mode 25 1 FG Frame Ground Common 2 Transmit Data A To Model 1035 3 Receive Data A From Model 1035 4 RTS Request to Send To Model 1035 5 CTS Clear to Send From Model...