5.0  OPERATION

Once the Model 1035 is properly configured and installed, it should

operate transparently—as if it were a standard cable connection.
Section 5.0 describes reading the LED status monitors, powering-up
and using the built-in V.52 and V.54 test modes.  The Model 1035 is
powered by a 7.5V DC external wall mount transformer.  To power up
the unit, connect the power supply cord to the power jack on the rear of
the Model 1035 and plug the power adapter into the wall.  There is no
ON/OFF switch.

5.1  FRONT PANEL SWITCHES

During normal operation, both front panel switches should be in the

“normal” center position.  To operate a test mode, see Section 5.3.

5.2  LED STATUS MONITORS

The Model 1035 features five front panel LEDs that monitor

transmit data, carrier detect, two test modes and power.  Figure 6
shows the front panel location of each LED.  Following Figure 6 is a
description of each LED’s function.

PWR = Glows green when the Model 1035 is powered up.
TD =

Glows red for a “space” on transmit data.

CD =

Glows red for high on carrier detect.

BERT = Glows red when bit errors occur in test mode (511 pattern);

Lights when 511/E test pattern has been selected.

LOOP = Glows red when the Model 1035 is in remote digital loopback

or local analog loopback mode.

5.3  TEST MODES

The Model 1035 offers two V.54 test modes to evaluate the

condition of the modems and the communication link.  These tests can
be activated physically from the front panel, or via the interface.  Note:
V.54 test modes on the Model 1035 are available for point-to-point
applications only.

5.3.1  Local Analog Loopback (LAL)

The Local Analog Loopback (LAL) test checks the operation of the

local Model 1035, and is performed separately on each unit.  Any data
sent to the local Model 1035 in this test mode will be echoed (returned)
back to the user device.  For example, characters typed on the
keyboard of a terminal will appear on the terminal screen.  To perform a
LAL test, follow these steps:

A.

Activate LAL.  This may be done in one of two ways:  First, by

moving the front panel toggle switch DOWN to “LAL”.  Second, by
raising pin 18 on the interface.  (Note:  Make sure DIP switch SW1-8 is
OFF).  Once LAL is activated, the Model 1035 transmitter output is
connected to its own receiver.  The “test” LED should be lit.

B.

Verify that the data terminal equipment is operating properly

and can be used for a test.  If a fault is indicated, call a technician or
replace the unit.

C.  Perform a BER (bit error rate) test on each unit.  If the BER test

equipment indicates no faults, but the data terminal indicates a fault,
follow the manufacturer’s checkout procedures for the data terminal.
Also, check the interface cable between the terminal and the Model
1035.

5.3.2  Remote Digital Loopback (RDL)

The Remote Digital Loopback (RDL) test checks the performance

of both the local and remote Model 1035s, and the communication link
between them.  Any characters sent to the remote Model 1035 in this
test mode will be returned back to the originating device.  For example,
characters typed on the keyboard of the local terminal will appear on
the local terminal screen after having been passed to the remote Model
1035 and looped back.  To perform an RDL test, follow these steps:

(continued)

12

Figure 6. Model 1035’s LED indicators and test switches 

TD

CD

PWR

BERT

LOOP

511/E RDL

NORMAL

511   LAL

11

Содержание RS-232

Страница 1: ...ER MANUAL MODEL 1035 Powered High Speed Short Range Modem RS 232 and V 35 versions SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1035 A Doc 054071UA Revised 7 6...

Страница 2: ...insured to Patton Electronics All returns must have a Return Materials Authorization number on the outside of the shipping container This number may be obtained from Patton Electronics Technical Servi...

Страница 3: ...structions on opening the Model 1035 case see Section 3 2 Figure 2 shows the orientation of the switches including the ON OFF positions 3 Figure 2 Close up of configuration switches OFF 1 2 3 4 5 6 7...

Страница 4: ...f n a SW1 4 Not Used Off n a SW1 5 Not Used Off n a SW1 6 Not Used Off n a SW1 7 Not Used Off n a SW1 8 V 54 Enable Disable Off Enabled Figure 3 Summary of DIP switch settings for set SW1 SW1 8 V 54 E...

Страница 5: ...35 supports communication between two RS 232 devices or two V 35 devices at distances to 6 miles and data rates to 64 Kbps There are two essential requirements for installing the Model 1035 1 These un...

Страница 6: ...r host A direct connection to the RS 232 or V 35 DTE port is most desirable If you must use a cable to connect the Model 1035 to the DTE port make sure it is a straight through cable of the shortest p...

Страница 7: ...Local Analog Loopback LAL The Local Analog Loopback LAL test checks the operation of the local Model 1035 and is performed separately on each unit Any data sent to the local Model 1035 in this test m...

Страница 8: ...problem with the twisted pair line between the modems You should then check the twisted pair line for proper connections and continuity 5 3 3 Using the V 52 BER Test Independently The V 52 BER test c...

Страница 9: ...l Loopback 21 From Model 1035 Test Mode 25 1 FG Frame Ground Common 2 Transmit Data A To Model 1035 3 Receive Data A From Model 1035 4 RTS Request to Send To Model 1035 5 CTS Clear to Send From Model...

Отзывы: