APPENDIX B

SPECIFICATIONS

Transmission Format:  Asynchronous or synchronous

Range:  2.5 Km at all data rates, 5 Km at specified data rates

Data rates:  0 to 38.4 Kbps (async.); 2.4, 9.6, 19.2, 38.4, 56, 64, 192

and 256 Kbps (sync.)

Interface: EIA RS-232 / CCITT V.24 

Transmit Mode:  Single 62.5 or 50 µ core, multi-mode fiber cable

Clocking: Internal or external

Handshaking:  Software (X-ON/X-OFF) or hardware (RTS/CTS), both

modes available at all times

Application: Point-to-point

Typical Link Budget: 8 dB with 50 µ cable; 12 dB with 62.5 µ cable

Responsivity Minimum: 0.12 A/w

LED Indicators:  TD, RD, RTS, CTS, Power, Test

Diagnostics:  Local and remote loopback

Connectors: DB-25 female (RS-232), ST or SMA (fiber)

Dimensions:  4.127”w x 1.52”h x 5.0”l

Power Supply:  Wall-mount, 10VAC, 700mA

APPENDIX C

RS-232 INTERFACE STANDARD

15

16

1- (FG) Frame Ground
2- (TD) Transmit Data

To Model 1180

3- (RD) Receive Data

From Model 1180

4- (RTS) Request to Send

To Model 1180

5- (CTS) Clear to Send

From Model 1180

6- (DSR) Data Set Ready

From Model 1180

7- (SG) Signal Ground
8- (DCD) Data Carrier Detect

From Model 1180

To Model 1180

Data Term. Ready (DTR) - 20

DIRECTION

STANDARD “DCE” SETTING

DIRECTION

To Model 1180

Transmitting Timing LXC - 24

From Model 1180

Transmitting Timing - 15  

From Model 1180

Receiver Timing - 17

Содержание 1180

Страница 1: ...USER MANUAL MODEL 1180 Single Fiber Short Range Modem SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 Part 07M1180 B Doc 017071UB Revised 1 5 96...

Страница 2: ...and non warranty repairs must be returned freight prepaid and insured to Patton Electronics All returns must have a Return Materials Authorization number on the outside of the shipping container This...

Страница 3: ...s data rate and the mode of synchronization Sync Mode between two Model 1180s The Sync Mode setting active in both asynchronous and synchronous operating modes defines the packet length of the data st...

Страница 4: ...2X Off Off On Off 56 0 1X Off Off Off Off 64 0 1X Off Off Off On 64 0 2X Off Off On On 192 0 1X On On On On 256 0 1X Switch 6 Reset Switch 6 lets you reset the Model 1180 without powering down the un...

Страница 5: ...t wants to connect to a DTE When connecting the Model 1180 to DTE hardware such as a PC host or terminal use a straight through RS 232 cable When connecting the Model 1180 to DCE hardware such as a mo...

Страница 6: ...steady the Model 1180 is powered up Note Make sure the front panel toggle switch on both Model 1180s is set to NORMAL After both the local and remote Model 1180s are powered up a synchronization proc...

Страница 7: ...k to the originating device For example characters typed on the keyboard of the local terminal will appear on the local terminal screen after having been passed to the remote Model 1180 and looped bac...

Страница 8: ...k for continuity Plug transformer into Model 1180 Check for ongoing power loss or break in fiber if CD does not go high within 60 seconds Make sure the Test Mode switch is set to NORMAL on both Model...

Страница 9: ...nsivity Minimum 0 12 A w LED Indicators TD RD RTS CTS Power Test Diagnostics Local and remote loopback Connectors DB 25 female RS 232 ST or SMA fiber Dimensions 4 127 w x 1 52 h x 5 0 l Power Supply W...

Отзывы: