A.  Activate local loopback by moving the front panel toggle switch

DOWN to “Local”.  Once local loopback is activated, the Model 1180
transmit output is connected to its own receiver.  The “test” LED should
glow.  Note:  Even though the local Model 1180 cannot communicate
with the remote Model 1180 in this mode, the synchronized connection
between the two modems remains intact.

B.  Verify that the data terminal equipment is operating properly and

can be used for a test.  If a fault is indicated, call a technician or replace
the unit.

C.  Perform a BERT (bit error rate) test on each unit.  If the BERT

test equipment indicates no faults, and the data terminal indicates a
fault, follow the manufacturer’s checkout procedures for the data
terminal.  Also, check the RS-232 interface cable between the terminal
and the Model 1180.

5.3.2  REMOTE LOOPBACK

The remote loopback test checks the performance of both the local

and remote Model 1180s, 

and the communication link between them

(Figure 7).  Any characters sent to the remote Model 1180 in this test
mode will be returned back to the originating device.  For example,
characters typed on the keyboard of the local terminal will appear on
the local terminal screen 

after having been passed to the remote Model

1180 and looped back.  To perform a remote loopback test, follow these
steps:

A.  Activate remote loopback by moving the front panel toggle switch

UP to “Remote”.  The “test” LED should glow.  

B.  Perform a BERT (bit error rate) test on the system.

C.  If the BERT test equipment indicates a fault, and the local

loopback test was successful for both Model 1180s, this suggests a
problem with the fiber communication line connecting the modems.  You
should then test the fiber line for proper connections and continuity.

5.4  POWER-DOWN

Turn off the Model 1180 by simply unplugging the AC power adapter

from the wall.  There is no power switch on the Model 1180.

11

12

RD

TD

TD

RD

Local 1070RC

In Normal Mode

Remote 1070RC

In Normal Mode

TX+

TX-

RX-

RX+

RX+

RX-

TX-

TX+

RD

TD

TD

RD

Local 1070RC

In Loopback Mode

Remote 1070RC

In Normal Mode

RX+

RX-

TX-

TX+

TX+

TX-

RX-

RX+

RD

TD

TD

RD

Local 1080RC

In Normal Mode

Remote 1080RC

In Normal Mode

TX+

TX-

RX-

RX+

RX+

RX-

TX-

TX+

RD

TD

TD

RD

Local 1080RC

In Loopback Mode

Remote 1080RC

In Normal Mode

RX+

RX-

TX-

TX+

TX+

TX-

RX-

RX+

RD

TD

TD

RD

Local 1180RC

In Normal Mode

Remote 1180RC

In Normal Mode

TX

RX

RX

TX

RD

TD

TD

RD

Local 1180RC

In Loopback Mode

Remote 1180RC

In Normal Mode

RX

TX

TX

RX

Figure 7. Local and remote loopback test modes

Содержание 1180

Страница 1: ...USER MANUAL MODEL 1180 Single Fiber Short Range Modem SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 Part 07M1180 B Doc 017071UB Revised 1 5 96...

Страница 2: ...and non warranty repairs must be returned freight prepaid and insured to Patton Electronics All returns must have a Return Materials Authorization number on the outside of the shipping container This...

Страница 3: ...s data rate and the mode of synchronization Sync Mode between two Model 1180s The Sync Mode setting active in both asynchronous and synchronous operating modes defines the packet length of the data st...

Страница 4: ...2X Off Off On Off 56 0 1X Off Off Off Off 64 0 1X Off Off Off On 64 0 2X Off Off On On 192 0 1X On On On On 256 0 1X Switch 6 Reset Switch 6 lets you reset the Model 1180 without powering down the un...

Страница 5: ...t wants to connect to a DTE When connecting the Model 1180 to DTE hardware such as a PC host or terminal use a straight through RS 232 cable When connecting the Model 1180 to DCE hardware such as a mo...

Страница 6: ...steady the Model 1180 is powered up Note Make sure the front panel toggle switch on both Model 1180s is set to NORMAL After both the local and remote Model 1180s are powered up a synchronization proc...

Страница 7: ...k to the originating device For example characters typed on the keyboard of the local terminal will appear on the local terminal screen after having been passed to the remote Model 1180 and looped bac...

Страница 8: ...k for continuity Plug transformer into Model 1180 Check for ongoing power loss or break in fiber if CD does not go high within 60 seconds Make sure the Test Mode switch is set to NORMAL on both Model...

Страница 9: ...nsivity Minimum 0 12 A w LED Indicators TD RD RTS CTS Power Test Diagnostics Local and remote loopback Connectors DB 25 female RS 232 ST or SMA fiber Dimensions 4 127 w x 1 52 h x 5 0 l Power Supply W...

Отзывы: