Patton electronics 1180 Скачать руководство пользователя страница 3

3.0  CONFIGURATION

The Model 1180 uses a set of eight external DIP switches that

allow configuration to a wide range of applications.  Because all eight
switches are in one externally accessible DIP package, there is no need
to open the Model 1180’s case for configuration.  The switches allow
you to control data rates and clocking methods.  Figures 1, 2 and  3
summarize the switch locations, positions and functions.

3

4

1

2

3

4

5

6

7

8

ON

FRONT

REAR

1

2

3

4

5

6

7

8

ON

OFF

ON

3.1  DETAILED SWITCH SETTINGS

This section provides detailed information about the function of

each DIP switch and lists all possible settings.  Use this section as
configuration guide for applications where the Model 1180’s default
would not provide correct results.

Switch 1:   Reserved for Future Use

Switches 2 though 5:   Data Rate (Sync. Mode)

Switches 2 through 5 determine two configuration parameters:

synchronous or asynchronous data rate and the mode of
synchronization (Sync. Mode) between two Model 1180s.  The “Sync.
Mode” setting (active in both asynchronous and synchronous operating
modes) defines the packet length of the data stream between the two
Model 1180s.  

Simply put, the “2X” setting doubles the space between data

packets when compared with the “1X” setting.  A Sync. Mode setting of
“2X” facilitates communication distances up to 5 Km.  A Sync. Mode
setting of “1X” limits communication distances to 2.5 Km.  The following
table shows every possible data rate/Sync. Mode switch setting for the
Model 1180.

SWITCH SUMMARY TABLE

Position

Function

Factory Default

Switch 1

RESERVED

Off   

Switch 2

Data Rate (Sync Mode)

On       

Switch 3

Data Rate (Sync Mode)

Off

Switch 4

Data Rate (Sync Mode)

Off

Switch 5

Data Rate (Sync Mode)

On        

Switch 6

Reset

Off

Operating Mode

Switch 7

Handshaking

On

Control Signal Mode

Switch 8

Clocking Method

Off

Internal Clock

0 - 19.2

Async (2x)

}

Figure 1. Switch locations underneath Model 1180

Figure 2. Close up of 1180 DIP switch package showing OFF/ON positions.

Figure 3. Summary of switch settings, showing factory defaults

Содержание 1180

Страница 1: ...USER MANUAL MODEL 1180 Single Fiber Short Range Modem SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 Part 07M1180 B Doc 017071UB Revised 1 5 96...

Страница 2: ...and non warranty repairs must be returned freight prepaid and insured to Patton Electronics All returns must have a Return Materials Authorization number on the outside of the shipping container This...

Страница 3: ...s data rate and the mode of synchronization Sync Mode between two Model 1180s The Sync Mode setting active in both asynchronous and synchronous operating modes defines the packet length of the data st...

Страница 4: ...2X Off Off On Off 56 0 1X Off Off Off Off 64 0 1X Off Off Off On 64 0 2X Off Off On On 192 0 1X On On On On 256 0 1X Switch 6 Reset Switch 6 lets you reset the Model 1180 without powering down the un...

Страница 5: ...t wants to connect to a DTE When connecting the Model 1180 to DTE hardware such as a PC host or terminal use a straight through RS 232 cable When connecting the Model 1180 to DCE hardware such as a mo...

Страница 6: ...steady the Model 1180 is powered up Note Make sure the front panel toggle switch on both Model 1180s is set to NORMAL After both the local and remote Model 1180s are powered up a synchronization proc...

Страница 7: ...k to the originating device For example characters typed on the keyboard of the local terminal will appear on the local terminal screen after having been passed to the remote Model 1180 and looped bac...

Страница 8: ...k for continuity Plug transformer into Model 1180 Check for ongoing power loss or break in fiber if CD does not go high within 60 seconds Make sure the Test Mode switch is set to NORMAL on both Model...

Страница 9: ...nsivity Minimum 0 12 A w LED Indicators TD RD RTS CTS Power Test Diagnostics Local and remote loopback Connectors DB 25 female RS 232 ST or SMA fiber Dimensions 4 127 w x 1 52 h x 5 0 l Power Supply W...

Отзывы: