background image

Switch S5-2:  2-Wire/4-Wire

Use Switch S5-2 to configure 2-Wire or 4-Wire operation.

S5-2

Setting

Description

Off

2-Wire

2-Wire Operation

On

4-Wire

4-Wire Operation

Switch S5-3:  Enable LAL and RDL from DTE

Use Switch S5-3 to enable or disable the Local Analog Loopback

and Remote Digital Loopback control from the DTE.

S5-3

Setting

Description

On

Enabled

LAL and RDL enabled

Off

Disabled

LAL and RDL disabled

Switch S5-4:  Enable Front Panel Swtiches
Use Switche S5-4 to enable or disable the front panel switches.

S5-4

Setting

Description

On

Enabled

Front Panel Switches 
enabled.

Off

Disabled

Front Panel Switches 
disabled.

3.2 CONFIGURE THE SOFTWARE SWITCHES

The Model 1092ARC features a menu-driven command system

that allows you to configure the local 1092ARC.  The  software control
port signals of the 1092ARC are carried to each card in the rack along
the internal power bus board.  Access to all rack card control ports is
provided by a single 

PATTON Model 1001CC Control Card (see Model

Model 1001CC User Manual).  After setting the control port address
(Section 3.1.3), use the following instructions to configure the unit:  

1)

Connect the serial RS-232 port of a V100 or similar DTE with 
terminal emulation to the EIA-561 control port on the Model
1001CC control card.  To construct an RS-232 to EIA-561
patch cable, refer to the control port pinout diagram in
Appendix D.  Refer to Appendix C to order a pre-made cable.

2)

Power up the terminal and set its RS-232 port as follows:

9600 Baud
8 data bits, 1 stop bit, no parity
Local echo 
CR-CR/LF on inbound data
ANSI, VT-100 emulation

3.

Press [CTRL+B] on the terminal followed by the two-digit 
control port address.   

12

The following table A-2 shows the bit setting to configure the

address.

The configuration switches on S5 allow you to specify the data

rate, 2-wire/4-wire selection, and enable or disable loopback
diagnostics.  Default settings of S5 are shown in the table below.
Switch S5-1:  Data Rate

Use Switch S5-1 with Switches S1-1 and S1-2 to enable additional

data rates.  The table in Section 3.1.2 shows all possible bit rate
settings for Switches S1-1, S1-2, and S5-1.

11

Position

Function

Factory Default

S5-1

Data Rate

Off

S5-2

2-Wire/4-Wire

Off   2-wire

S5-3

Enable LAL or RDL from DTE

On   Enable

S5-4

Front Panel Switch Control

Off   Enable

S5 SUMMARY TABLE

1- 2 - 3 - 4 - 5 - 6 - 7  -  8  -  9  - 10 - 11 - 12 - 13 - NMS - PS2 - PS1

Table A-1.  Starting Address Setting

Upper (Lower) Nibble              

S2-7  

S2-6

S2-5

(S2-4)

(S2-3)

(S2-2)

(S2-1)

0

ON

ON

ON

ON

1

ON

ON

ON

OFF

2

ON

ON

OFF

ON

3

ON

ON

OFF

OFF

4

ON

OFF

ON

ON

5

ON

OFF

ON

OFF

6

ON

OFF

OFF

ON

7

ON

OFF

OFF

ON

8*                                         OFF

ON

ON

ON

9*    

OFF

ON

ON

OFF

A*     

OFF

ON

OFF

ON

B*     

OFF

ON

OFF

OFF

C*                                        OFF

OFF

ON

ON

D*     

OFF

OFF

ON

OFF

E*     

OFF

OFF

OFF

ON

F*     

OFF

OFF

OFF

OFF

Table A-2.  Bit Setting to Configure the Address

Address     S2-7      S2-6     S2-5       S2-4      S2-3     S2-2       S2-1
(Dec.)

0x01 (1)        ON       ON      ON           ON      ON

ON

OFF

0x10 (16)

0x35 (53)

ON

ON

ON

ON

ON

ON

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

* 8 - F are 

only 

available for Lower Nibble.

3.1.4 Configuration Switch Set “S5”

Содержание 1092ARC

Страница 1: ...gh Speed 2 Wire 4 Wire Synchronous and Asynchronous Rack Mount Modem Card SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1092ARC C Doc 033041UB Revised 03 23 00 A...

Страница 2: ...into a different AC outlet such that the computing equipment and receiver are on different branches In the event the user detects intermittent or continuous product malfunction due to nearby high powe...

Страница 3: ...supports 2B1Q encoding Automatic Equalization and Auto Gain Control The 1092ARC is fully SNMP manageable using Patton s Model 1001MC Management Card Software configuration is performed via the VT100 s...

Страница 4: ...1092ARC showing configuration switches and interface board SW1 SW2 SW5 Interface Driver Board THIS SIDE UP FOR V 35 FRONT Figure 2 Close up of configuration switches NOTE The ON position is oriented...

Страница 5: ...Reserved Off Off On 19 2 kbps Reserved Possible Bit Rate Settings Switch S1 1 S1 2 and S5 1 3 1 1 Reversible Interface Driver Board The Model 1092ARC Series features switchable interface driver board...

Страница 6: ...upplies and increment the numbers by one as you go from left to right Setting the addresses in this manner will make configuration easier as you start using the web page management An example of this...

Страница 7: ...Appendix C to order a pre made cable 2 Power up the terminal and set its RS 232 port as follows 9600 Baud 8 data bits 1 stop bit no parity Local echo CR CR LF on inbound data ANSI VT 100 emulation 3 P...

Страница 8: ...play the configuration of the software switches To use the software configuration for the Active Configuration select MAIN MENU Option 5 Then select Use Software Switches Finally select MAIN MENU Opti...

Страница 9: ...ust be a Master Clock either internal or external and the other must be Slaved to the Receive Clock MAIN MENU Option 4 Setup Software Configuration Select Option 4 to edit the software configuration o...

Страница 10: ...or software switch settings as the active configuration After changing this setting select MAIN MENU Option 8 to implement the changes 18 2 Wire 4 Wire Selection 1 4 Wire Mode 2 2 Wire Mode 4 DSR Duri...

Страница 11: ...and 511 and starts the internal 511 generator and detectors Remote Digital Initiates the Remote Digital Loopback test Loop and and starts the 511test patterns In this test 511 with errors the 511 pat...

Страница 12: ...ap Function Position 1 2 Position 2 3 JB3 DTE Shield Pin1 FRGND Connected Open JB4 FRGND SGND Connected Open Indicates default setting 3 3 CONFIGURE THE REAR INTERFACE CARD The Model 1092ARC Series ha...

Страница 13: ...ted Open Indicates default setting 24 3 3 2 Model 1001RCM13445 Rear Card Strap Settings Figure 7 shows the strap location for the Model 1001RCM13445 M 34 RJ 45 rear card This strap determines whether...

Страница 14: ...he power supply slides in from the front and the rear card slides in from the rear They plug into one another in the middle of the rack The front card is then secured by thumb screws and the rear card...

Страница 15: ...ype cable are not acceptable 28 4 2 INSTALL THE MODEL 1092ARC SERIES INTO THE CHASSIS The Model 1092ARC Series is comprised of a front card and a rear card The two cards meet inside the rack chassis a...

Страница 16: ...d from the remote modem Green indicates that the remote modem s carrier is being received DTR glows green to indicate that the Data Terminal Ready signal from the terminal is active 30 Figure 11 The M...

Страница 17: ...o the remote Model 1092ARC and looped back To perform an RDL test follow these steps 32 Figure 13 Remote Digital Loop Local 1092ARC Remote 1092ARC Important Do not send a 511 test pattern from the tes...

Страница 18: ...screws washers 10 25M 35M 1 Cable 6 ft DB 25 male to M 34 male 1010 10 Terminal Block 2 Position Male 07M1092ARC User Manual 34 1 Activate RDL This may be done in three ways Move the front panel toggl...

Страница 19: ...Remote Digital Loop 24 XTC External Transmit Clock 36 APPENDIX B MODEL 1092ARC TERMINAL INTERFACE PIN ASSIGNMENT M 34F Connector DCE V 35 Interface Pin Signal B SGND Signal Ground C RTS Request to Se...

Страница 20: ...re Tip 4 Tip 5 Ring 6 4 Wire Ring 7 N C No Connection 8 N C No Connection Copyright 2000 Patton Electronics Company All Rights Reserved APPENDIX C PATTON MODEL 1092ARC CONTROL PORT PIN ASSIGNMENT RJ 4...

Отзывы: