background image

To perform an LLB test, follow these steps:

1.

Activate LLB.  This may be done in one of three ways:  

-  Move the front panel toggle switch to the right to 

“Local”.  

-  Raise the LLB signal on the interface (see Appendix B).  
-  Set Local Loop from the VT100 screen.

Once LLB is activated, the Model 1092ARC transmitter output is

connected to its own receiver. Data is also looped back to the line.  The
“TM” LED should be lit. 

2.

Verify that the data terminal equipment is operating properly 
and can be used for a test.  

3.  Perform a V.52 BER (bit error rate) test as described in 

Section 5.2.3.  If the BER test equipment indicates no faults, 
but the data terminal indicates a fault, follow the 
manufacturer’s checkout procedures for the data terminal.  
Also, check the interface cable between the terminal and the 
Model 1092ARC.

5.2.2  Remote Digital Loopback (RDL)

The Remote Digital Loopback (RDL) test checks the performance

of both the local and remote Model 1092ARCs, and the communication
link between them.  Any characters sent to the remote Model 1092ARC
in this test mode will be returned back to the originating device (see
Figure 13, below).  For example, characters typed on the keyboard of
the local terminal will appear on the local terminal screen after having
been passed to the remote Model 1092ARC and looped back. 

To perform an RDL test, follow these steps:

32

Figure 13.  

Remote Digital Loop

Local 1092ARC

Remote 1092ARC

Important! Do not send a 511 test pattern from the test
equipment when you connect external test equipment to the
1092ARC .

RDL initiated

ER

glows red to indicate the likelihood of a Bit Error 
in the received signal.  During the 511 or 511/E 
test, ER flashes to indicate that the Test Pattern 
Detector has detected a bit error.

TM 

glows yellow to indicate that the Model 1092ARC 
has been placed in Test Mode.  The unit can be 
placed in test mode by  the local user or by the 
remote user.

NS

(No Signal) glows red to indicate that the local 
Model 1092ARC has not yet connected with the 
remote Model 1092ARC.

5.2  TEST MODES

The Model 1092ARC offers two proprietary loopback test modes,

plus a built-in V.52 BER test pattern generator, to evaluate the condition
of the modems and the communication link.  These tests can be
activated physically from the front panel, or via the interface.  

5.2.1  Local Line Loopback (LLB)

The Local Line Loopback (LLB) test checks the operation of the

local Model 1092ARC, and is performed separately on each unit.  Any
data sent to the local Model 1092ARC in this test mode will be echoed
(returned) back to the user device (see Figure 12, below).  For
example, characters typed on the keyboard of a terminal will appear on
the terminal screen.

31

Figure 12. Local Line Loopback

LLB initiated

Содержание 1092ARC

Страница 1: ...gh Speed 2 Wire 4 Wire Synchronous and Asynchronous Rack Mount Modem Card SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1092ARC C Doc 033041UB Revised 03 23 00 A...

Страница 2: ...into a different AC outlet such that the computing equipment and receiver are on different branches In the event the user detects intermittent or continuous product malfunction due to nearby high powe...

Страница 3: ...supports 2B1Q encoding Automatic Equalization and Auto Gain Control The 1092ARC is fully SNMP manageable using Patton s Model 1001MC Management Card Software configuration is performed via the VT100 s...

Страница 4: ...1092ARC showing configuration switches and interface board SW1 SW2 SW5 Interface Driver Board THIS SIDE UP FOR V 35 FRONT Figure 2 Close up of configuration switches NOTE The ON position is oriented...

Страница 5: ...Reserved Off Off On 19 2 kbps Reserved Possible Bit Rate Settings Switch S1 1 S1 2 and S5 1 3 1 1 Reversible Interface Driver Board The Model 1092ARC Series features switchable interface driver board...

Страница 6: ...upplies and increment the numbers by one as you go from left to right Setting the addresses in this manner will make configuration easier as you start using the web page management An example of this...

Страница 7: ...Appendix C to order a pre made cable 2 Power up the terminal and set its RS 232 port as follows 9600 Baud 8 data bits 1 stop bit no parity Local echo CR CR LF on inbound data ANSI VT 100 emulation 3 P...

Страница 8: ...play the configuration of the software switches To use the software configuration for the Active Configuration select MAIN MENU Option 5 Then select Use Software Switches Finally select MAIN MENU Opti...

Страница 9: ...ust be a Master Clock either internal or external and the other must be Slaved to the Receive Clock MAIN MENU Option 4 Setup Software Configuration Select Option 4 to edit the software configuration o...

Страница 10: ...or software switch settings as the active configuration After changing this setting select MAIN MENU Option 8 to implement the changes 18 2 Wire 4 Wire Selection 1 4 Wire Mode 2 2 Wire Mode 4 DSR Duri...

Страница 11: ...and 511 and starts the internal 511 generator and detectors Remote Digital Initiates the Remote Digital Loopback test Loop and and starts the 511test patterns In this test 511 with errors the 511 pat...

Страница 12: ...ap Function Position 1 2 Position 2 3 JB3 DTE Shield Pin1 FRGND Connected Open JB4 FRGND SGND Connected Open Indicates default setting 3 3 CONFIGURE THE REAR INTERFACE CARD The Model 1092ARC Series ha...

Страница 13: ...ted Open Indicates default setting 24 3 3 2 Model 1001RCM13445 Rear Card Strap Settings Figure 7 shows the strap location for the Model 1001RCM13445 M 34 RJ 45 rear card This strap determines whether...

Страница 14: ...he power supply slides in from the front and the rear card slides in from the rear They plug into one another in the middle of the rack The front card is then secured by thumb screws and the rear card...

Страница 15: ...ype cable are not acceptable 28 4 2 INSTALL THE MODEL 1092ARC SERIES INTO THE CHASSIS The Model 1092ARC Series is comprised of a front card and a rear card The two cards meet inside the rack chassis a...

Страница 16: ...d from the remote modem Green indicates that the remote modem s carrier is being received DTR glows green to indicate that the Data Terminal Ready signal from the terminal is active 30 Figure 11 The M...

Страница 17: ...o the remote Model 1092ARC and looped back To perform an RDL test follow these steps 32 Figure 13 Remote Digital Loop Local 1092ARC Remote 1092ARC Important Do not send a 511 test pattern from the tes...

Страница 18: ...screws washers 10 25M 35M 1 Cable 6 ft DB 25 male to M 34 male 1010 10 Terminal Block 2 Position Male 07M1092ARC User Manual 34 1 Activate RDL This may be done in three ways Move the front panel toggl...

Страница 19: ...Remote Digital Loop 24 XTC External Transmit Clock 36 APPENDIX B MODEL 1092ARC TERMINAL INTERFACE PIN ASSIGNMENT M 34F Connector DCE V 35 Interface Pin Signal B SGND Signal Ground C RTS Request to Se...

Страница 20: ...re Tip 4 Tip 5 Ring 6 4 Wire Ring 7 N C No Connection 8 N C No Connection Copyright 2000 Patton Electronics Company All Rights Reserved APPENDIX C PATTON MODEL 1092ARC CONTROL PORT PIN ASSIGNMENT RJ 4...

Отзывы: