manualshive.com logo in svg
background image

1.0  WARRANTY INFORMATION 

Patton Electronics warrants all Model 1090 components to be

free from defects, and will—at our option—repair or replace the product
should it fail within one year from the first date of shipment.

This warranty is limited to defects in workmanship or materials, and

does not cover customer damage, abuse or unauthorized modification.
If this product fails or does not perform as warranted, your sole
recourse shall be repair or replacement as described above.  Under no
condition shall Patton Electronics be liable for any damages incurred
by the use of this product.  These damages include, but are not limited
to, the following:  lost profits, lost savings and incidental or
consequential damages arising from the use of or inability to use this
product.  Patton Electronics specifically disclaims all other warranties,
expressed or implied, and the installation or use of this product shall be
deemed an acceptance of these terms by the user. 

1.1  RADIO AND TV INTERFERENCE

The Model 1090 generates and uses radio frequency energy, and if

not installed and used properly—that is, in strict accordance with the
manufacturer's instructions—may cause interference to radio and
television reception.  The Model 1090 has been tested and found to
comply with the limits for a Class A computing device in accordance
with the specifications in Subpart J of Part 15 of FCC rules, which are
designed to provide reasonable protection from such interference in a
commercial installation.  However, there is no guarantee that
interference will not occur in a particular installation.  If the Model 1090
does cause interference to radio or television reception, which can be
determined by removing power from the unit, the user is encouraged to
try to correct the interference by one or more of the following measures:
moving the computing equipment away from the receiver, re-orienting
the receiving antenna and/or plugging the receiving equipment into a
different AC outlet (such that the computing equipment and receiver are
on different branches).

1.2  CE NOTICE

The CE symbol on your Patton Electronics equipment indicates

that it is in compliance with the Electromagnetic Compatibility (EMC)
directive and the Low Voltage Directive (LVD) of the Union European
(EU).  A Certificate of Compliance is available by contacting Technical
Support.

1

1.2  SERVICE

All warranty and non-warranty repairs must be returned freight

prepaid and insured to Patton Electronics.  All returns must have a
Return Materials Authorization number on the outside of the shipping
container.  This number may be obtained from Patton Electronics
Technical Service at

telephone: (301) 975-1007, 
web address:  http://www.patton.com
email:  [email protected].  

NOTE: Packages received without an RMA number will not be
accepted.

Patton Electronics’ technical staff is also available to answer any

questions that might arise concerning the installation or use of your
Model 1090.  Technical Service hours:  8AM to 5PM EST, Monday
through Friday.

2

Содержание 1090

Страница 1: ...like this product and how we can meet your product needs today and in the future Web http www patton com Sales E mail sales patton com Support E mail support patton com Phone Sales 301 975 1000 Phone...

Страница 2: ...designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If the Model 1...

Страница 3: ...ndicators Data integrity is enhanced by automatic equalization and gain control The Model 1090 also incorporates transformer isolation and surge protection to guard data and connected equipment agains...

Страница 4: ...r Control The setting for switch S1 5 determines whether the carrier is constantly on or controlled by RTS This setting allows for operation in switched carrier or hardware handshaking applications S1...

Страница 5: ...rface to the serial port and to the power source This section tells you how to make these connections 4 1 CONNECTION TO THE TWISTED PAIR INTERFACE The Model 1090 supports communication between two ter...

Страница 6: ...the two thumbscrews and gently pull the module from the unit Apply equal force to the thumbscrews to keep the module straight during the removal process Installing the New QuickConnect Module 1 Make...

Страница 7: ...d as a DCE Reverse the DCE DTE orientation by pulling the strap out of its socket rotating it 180 then plugging the strap back into the socket You will see that the DCE DTE arrows now point in the opp...

Страница 8: ...odem Green indicates that the remote modem s carrier is being received 13 DTR Will glow green to indicate that the Data Terminal Ready signal from the terminal is active ER Will glow red to indicate t...

Страница 9: ...ment indicates a fault and the Local Analog Loopback test was successful for both Model 1090s you may have a problem with the line between the Model 1090s You should inspect the line for proper connec...

Страница 10: ...e link is in place and that the Model 1090 built in 511 generator and detector are working properly C This test can be done by one operator by first activating the local analog loop or remote digital...

Страница 11: ...ions may cause a reduction in maximum distance obtainable Functionality should not be affected Many environmental factors can affect the maximum distances obtainable at a particular site Use the data...

Страница 12: ...TC Test Control B 21 APPENDIX D 1092 INTERFACE PIN ASSIGNMENT DB 25F Connector DCE Pin Signal 1 FG Frame Ground 2 TD Transmit Data 3 RD Receive Data 4 RTS Request to Send 5 CTS Clear to Send 6 DSR Dat...

Страница 13: ...ntrol A AA TC Test Control B APPENDIX D 1090 INTERFACE PIN ASSIGNMENT DB 25F Connector DCE X 21 Interface Pin Signal 1 FG Frame Ground 2 TD Transmit Data 3 RD Receive Data 4 RTS Request to Send 5 CTS...

Страница 14: ...ta A 3 C Control A 4 R Receive Data A 5 I Indication A 6 S Signal Element Timing A 7 BT Byte Timing A 8 SGND Signal Ground 9 T Transmit Data B 10 C Control B 11 R Receive Data B 12 I Indication B 13 S...

Отзывы: