9
10
Switch S2-3: Extended Signaling Rate
The setting for switch S2-3 determines the range of variability the
Model 1065 Series “looks for” in asynchronous data rates (i.e., the
actual variance from a given frequency level the Model 1065 Series will
tolerate).
S2-3
Setting
Off
-2.5% to +1%
On
-2.5% to +2.3%
Switches S2-4 and S2-5: RTS/CTS Delay
The combined settings for switches S2-4 and S2-5 determine the
amount of delay between the time the unit “sees” RTS and when it
sends CTS. Options are no delay, 7 ms and 53 ms.
S2-4
S2-5
Setting
On
On
7 ms
Off
On
53 ms
On
Off
No delay
Off
Off
No delay
Switch S2-6 & S2-7: 2-Wire/4-Wire Mode Selection
The setting for switch S2-6 and S2-7 determines whether the
Model 1065 Series is operating in 2-wire or 4-wire mode.
S2-6
S2-7
Setting
On
On
4-wire (half duplex)
On
Off
4-wire (full duplex)
Off
On
2-wire (half duplex)
Switch S2-8: V.54 Loopback Test Enable
This switch enables or disables V.54 looping functions on the
1065RC.
S2-8
Setting
Off
V.54 Normal Operation
On
V.54 Testing Disabled
3.4 CONFIGURATION SWITCH SET “S3”
The DIP switches on S3 set the antistream control, local loopback
enable, remote loopback enable and receive (input) impedance levels
for the Model 1065RC. The default settings are shown in the S3 sum-
mary table.
S3-1: Input Impedance
The setting for switch S3-1, S3-2 determines the 1065RC’s input
impedance. This allows you to choose the optimum impedance setting
for your application. In long distance applications the impedance of the
cable must match the impedance of the load (or resistor) of the Model
1065RC. Thicker gauge cables requires a lower ohm setting, while a
thinner gauge cable should receive a higher ohm setting. See Figure
5.1 for a more details on selecting a setting.
S3-1
S3-2
Setting
On
On
130 ohms
On
Off
200 ohms
Off
On
320 ohms
Off
Off
High impedance (minimum 2k ohms)
S3 SUMMARY TABLE
Position
Function
Factory Default
S3-1
Input Impedance
On
S3-2
Input Impedance
Off
S3-3
Timing Mode
Off
S3-4
Topology
On Point to Point
S3-5
Local Loopback
Off
Disabled
S3-6
Remote Loopback
Off
Disabled
S3-7
Anti-stream Control
Off
S3-8
Anti-stream Control
Off
200 Ohms
Disabled
}
}
NOTE:
There are options on the data rate settings for S3-3.
Please go to Section 3.2 and refer to Figure 5 & Figure 5.1
for more information on the data rate settings.
Figure 7: Configuration Summary of S2 Switch Settings