background image

7

8

S1-5 and S1-6: Clock Source

Switches S1-5 and S1-6 are set in combination to determine the

transmit clock source for the Model 1065RC.

S1-5

S1-6

Setting

On

On

Internal transmit clock

Off

On

Receive recover clock

On

Off

External transmit clock

S1-7: Asynchronous/Synchronous Mode

The setting for switch S1-7 determines whether the Model 1065RC

is in asynchronous or synchronous operating mode.

S1-7

Setting

On

Asynchronous

Off

Synchronous

S1-8: Carrier Control Method

The setting for switch S1-8 determines whether the carrier is “con-

stantly on” or “controlled by RTS”. This setting allows for operation in
switched carrier, multipoint and/or hardware handshaking applications.

S1-8

Setting

Off

Constantly on

On

Controlled by RTS

3.3   CONFIGURATION SWITCH SET “S2”

The DIP switches on S2 set word length, extended signaling rate,

RTS/CTS delay, V.52 & V.54 diagnostic tests and 2- and 4-wire opera-
tion. The default settings for S2 are shown in Figure 6 below.

Switches S2-1 and S2-2: Word Length

Switches S2-1 and S2-2 are set in combination to determine the

word length for asynchronous data, including start and stop pulses.

S2-1

S2-2

Setting

Off

On

8 bits

On

On

9 bits

Off

Off

10 bits

On

Off

11 bits

14.4 kbps

OFF

OFF

OFF

ON

19.2 kbps

ON

ON

ON

OFF

28.8 kbps

OFF

ON

ON

OFF

38.4 kbps

ON

ON

OFF

OFF

57.6 kbps

OFF

ON

OFF

OFF

OFF

16.0 kbps

OFF

ON

OFF

ON

ON

OFF

OFF

32.0 kbps

OFF

OFF

OFF

ON

ON

OFF

OFF

64.0 kbps

OFF

ON

ON

OFF

ON

DATA RATE SETTINGS  S1-1 THROUGH S1-4 & S3-3

(continued)

SETTINGS

S1-1

S1-2

S1-3

S1-4

S3-3

Figure  5.1: Data Rate Settings S1-1 Through S1-4 & S3-3 (continued)

S2 SUMMARY TABLE

Position

Function

Factory Default

S2-1

Word Length

Off

S2-2

Word Length

Off

S2-3

Extended Signaling Rate

Off -2.5% to 1%

S2-4

RTS/CTS Delay

On

S2-5

RTS/CTS Delay

On

S2-6

2-Wire/4-Wire

On  (4-Wire) FDX

S2-7

2-Wire/4-Wire

Off  (4-Wire) FDX

S2-8

V.52/V.54

Off    V.54 Enabled

}

}

7 ms

10 bits

Figure 6: Configuration Summary of S2 Switch Settings

Содержание 1065RC

Страница 1: ...Industrial Synchronous Asynchronous Short Range Modem Rack Mount Card SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1065RC A Doc 058051UA Revised 08 11 99 An IS...

Страница 2: ...wever there is no guarantee that interfer ence will not occur in a particular installation If the Model 1065RC does cause interference to radio or television reception which can be determined by turni...

Страница 3: ...o point or multipoint Internal external or received loopback clocking Built in transformer isolation high speed surge protection Mono color LED indicators 2000VAC transformer isolation Mounts in Patto...

Страница 4: ...S2 and S3 which are mounted on the PC board Figure 1 These configura tion switches allow you to select data rates clocking methods V 52 V 54 tests word lengths extended signaling rates async or sync...

Страница 5: ...ic tests and 2 and 4 wire opera tion The default settings for S2 are shown in Figure 6 below Switches S2 1 and S2 2 Word Length Switches S2 1 and S2 2 are set in combination to determine the word leng...

Страница 6: ...the antistream control local loopback enable remote loopback enable and receive input impedance levels for the Model 1065RC The default settings are shown in the S3 sum mary table S3 1 Input Impedance...

Страница 7: ...ack test can be initiated by raising pin 21 on the RS 232 interface S3 6 Setting On RS 232 initiation enabled Off RS 232 initiation disabled S3 7 and S3 8 Antistream Control Switches S3 7 and S3 8 are...

Страница 8: ...odel 1000RMC12545 DB 25 RJ 45 rear cards These straps determine various grounding characteristics for the RS 232 and twisted pair lines Figure 10 shows the orientation of the rear interface card strap...

Страница 9: ...n power supply Measuring only 3 5 high the Model 1001R14P is designed to occupy only 2U in a 19 rack Sturdy front handles allow the Model 1001R14P to be extracted and transported conveniently 4 1 1 TH...

Страница 10: ...1 Slide the rear card into the back of the chassis along the metal rails provided 2 Secure the rear card using the metal screws provided 3 Slide the card into the front of the chassis It should meet...

Страница 11: ...4 Red Yellow 2 RCV RCV 5 Black Green 3 XMT GND 6 White Blue 1 GND RJ 45 4 Wire SIGNAL PIN COLOR COLOR PIN SIGNAL GND 2 Orange Brown 7 GND RCV 3 Black Green 5 XMT XMT 4 Red Yellow 6 RCV XMT 5 Green Bl...

Страница 12: ...lowing Figure 15 is a description of each LED s function 5 1 1 The TD and RD Indicators The TD and RD indicators blink green with data activity Off indi cates a low RS 232 logic level green indicates...

Страница 13: ...ate the condition of the modems and the communica tion link Both sets of tests can be activated physically from the front panel The V 54 test can also be activated from the RS 232 interface Note V 54...

Страница 14: ...king properly 5 If the remote BER test indicates that errors are present and the local analog loopback BER tests showed that both Model 1065RCs were functioning properly this suggests a problem with t...

Страница 15: ...1 h x 5 4 l APPENDIX B PATTON ELECTRONICS MODEL 1065RC CABLE RECOMMENDATIONS All Patton Electronics Company Short Range Modems are tested to the distances published in our Catalogs and Specification...

Страница 16: ...sted below Patton Model Description 1000RPEM 120 240V Rear Power Entry Module 1000RPSM 1 120 240V Front Power Supply Module 1000RPEM DC DC Rear Power Entry Module 1000RPSM 48A 48V Front Power Supply M...

Отзывы: