EN
88
Technical Data
Nominal voltage
18 V
Chuck size
1-10 mm
No-load speed (n
0
)
1
st
Gear
0-400/min
2
nd
Gear 0-1300/min
Max. torque
25 Nm (ISO 5393)
Max. screw diameter
8 mm
Max. drilling capacity
Steel
10 mm
Wood
30 mm
Torque setting
21 + drill
Sound pressure level (L
pA
)
69.3 dB(A) / Uncertainty K = 3 dB(A)
Sound power level (L
WA
)
80.3 dB(A) / Uncertainty K = 3 dB(A)
Max. vibration emission (a
hd
)
0.569 m/s
2
/ Uncertainty K = 1.5 m/s
2
Noise & Vibration
The values given in these instructions have
been measured in accordance with a stand-
ardized measurement procedure specified in
EN 60745 and can be used to compare tools.
It may be used for a preliminary assessment
of exposure. The declared vibration data rep-
resents the main applications of the tool, but
different uses of the tool or poor maintenance
can result in different vibration data. This may
significantly increase the vibration level over
the total working period.
An estimation of the vibration level should
also take into account the intervening periods,
when the tool is switched off or it running but
is not actually in use. This can result in a much
lower vibration load over the whole working
period.
Additional safety measure can be taken to
protect the user from effects of vibration:
Maintain the tool and its accessories, keep the
hands warm and organize work patterns.
Battery information
The battery is supplied partially charged. Com-
pletely charge the battery before using the tool
for the first time. The lithium ion battery can
be charged at any time without reducing its
service life. Interrupting the charging proce-
dure does not damage the battery.
The battery is protected against deep dis-
charging by the “Electronic Cell Protection
(ECP)”. When the battery is empty, the tool is
switched off by means of a protective circuit.
Therefore do not press the on / off switch
4
after the machine has switched off automati-
cally. The battery can be damaged.
Due to the NTC temperature control, the bat-
tery can only be charged at temperatures be-
tween 0 °C and 45 °C.
If the temperature exceeds 70 °C during op-
eration the three battery power check
8
LEDs
will flash rapidly and the tool is switched off by
means of a protective circuit. Once the tem-
perature is between -10 °C and 70 °C, the tool
can be operated normally.