background image

 3

 

NOTICE 

Gas floor model fryers are intended for commercial use only. Not for household use. 
Warranty will be void if service work is performed by other than a qualified technician, or if other than 

genuine replacement parts are installed. 
Be sure this Operator’s Manual and important papers are given to the proper authority to retain for 

future reference. 

Congratulations!  You  have  purchased  one  of  the  finest  pieces  of  commercial  cooking  equipment  on  the 

market. 
You will find that your new equipment, has been designed and manufactured to meet the toughest standards 

in the industry. Each equipment is carefully engineered and designs are verified through laboratory tests and 

field installations. With proper care and field maintenance, you will experience years of reliable, trouble-free 

operation

. For best results, read this manual carefully.

 

RETAIN THIS MANUAL FOR FUTURE REFERENCE. 

MODELS 

This manual is for Gas floor model  Fryers with 40 lbs, 50 lbs and 90 lbs  capacity frypots.  The capacity is 

described on the serial plate that is located inside the front door on the left side. 

Table of Contents 

Specifications ......................................................................................................................... 4

 

Installation .............................................................................................................................. 5

 

Operation .............................................................................................................................. 12

 

Cooking Hints ....................................................................................................................... 14

 

Cleaning ............................................................................................................................... 14

 

Service  (for authorized service technician only) .................................................................. 16

 

Parts ..................................................................................................................................... 20

 

Read  these  instructions  carefully  before  attempting  installation.  Installation  and  initial  startup  should  be 

performed  by  a  qualified  installer.  Unless  the  installation  instructions  for  this  product  are  followed  by  a 

qualified service technician (a person experienced in and knowledgeable with the installation of commercial 

gas  and/or  electric  cooking  equipment)  then  the  terms  and  conditions  on  the  Manufacturer’s  Limited 

Warranty will be rendered void and no warranty of any kind shall apply. 

Содержание PT-F3-NG

Страница 1: ...E INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT Please call the Service Department and ask for contact informati...

Страница 2: ...could result in injury product damage or property damage NOTICE This symbol refers to information that needs special attention or must be fully understood even though not dangerous WARNING FIRE HAZAR...

Страница 3: ...of reliable trouble free operation For best results read this manual carefully RETAIN THIS MANUAL FOR FUTURE REFERENCE MODELS This manual is for Gas floor model Fryers with 40 lbs 50 lbs and 90 lbs ca...

Страница 4: ...Height in Gas Connection in Total BTU hr Crated Weight lbs A B C D E F G H I 3 burner fryer 15 5 14 0 30 3 14 0 47 2 34 7 6 0 4 2 7 0 90 000 150 4 burner fryer 15 5 14 0 30 3 14 0 47 2 34 7 6 0 4 2 7...

Страница 5: ...50 000 39 Propane 10 W C 5 30 000 150 000 52 Minimum supply pressure is 4 W C for natural gas and 10 W C for propane Orifice sizes are for units installed at altitudes between 0 and 2000 feet above se...

Страница 6: ...are pre mounted on the base plates 1 Raise fryer sufficiently to allow legs or casters to be screwed into the base plate For safety shore up and support the fryer with an adequate blocking arrangemen...

Страница 7: ...iance is moved to its original installed position WARNING When this appliance is installed with casters it must be installed with the casters supplied a connector complying with either ANSI Z21 69 or...

Страница 8: ...8 Step 3 Flue Installation 1 Unpack the flue box and flue wrap 2 Slide the flue box over the flue and secure it with the two self tapping screws using a 5 16 socket 3 Slide the flue wrap over the flue...

Страница 9: ...FLOOR MODEL FRYERS SHALL BE INSTALLED WITH AT LEAST A 16 INCH SPACE BETWEEN THE FRYER AND SURFACE FLAMES FROM ADJACENT EQUIPMENT A FLAME GUARD IS ACCEPTABLE IF ALLOWED UNDER LOCAL CODE No additional s...

Страница 10: ...cked at installation and adjusted if necessary For orifice sizes and pressure regulator settings see the chart on page 4 If the fryer is being installed at over 2 000 feet altitude and that informatio...

Страница 11: ...SURES IN EXCESS OF 14 WC 1 2 PSIG or 3 45 kPa If the incoming gas pressure is in excess of 14 WC 1 2PSI 3 45 kPa a proper step down regulator will be required See PHOTO 1 for LP application Connect th...

Страница 12: ...knob down use a lit match to ignite the pilot Continue to press the knob down for about 30 seconds If the pilot does not stay lit when the knob is released repeat the lighting procedure and keep the k...

Страница 13: ...BURNERS WHEN THE FRYPOT IS EMPTY 7 To prevent burning or scorching the solid shortening keep the thermostat set at the lowest temperature until all the solid shortening between and above the tubes has...

Страница 14: ...d food CLEANING The equipment is constructed with the best quality materials and is designed to provide durable service when properly maintained To expect the best performance your equipment must be m...

Страница 15: ...residue from stainless steel use ordinary soap and water with or without detergent applied with a sponge or cloth Dry thoroughly with a clean cloth Never use vinegar or any corrosive cleaner To remove...

Страница 16: ...ontact your Service Representative for reliable service dependable advice or other assistance and for genuine factory parts All units are adjusted at the factory In case of problems in operation at in...

Страница 17: ...ace adjustment screw cap CHECKING AND ADJUSTING CALIBRATION OF THERMOSTAT All thermostat controls are carefully calibrated at the factory i e the dial is properly set to control appliance temperatures...

Страница 18: ...ed Combination gas valve is in OFF position Pilot gas not adjusted properly Gas supply to unit off Bad thermopile Dirty thermopile connections at combination gas valve or high limit Clogged orifice Dr...

Страница 19: ...19 Wiring Diagram...

Страница 20: ...cement parts may be ordered either through a Authorized Parts Distributor or a Authorized Service Agency When ordering parts please supply the Model Number Serial Number Part Number and Description In...

Страница 21: ...sys 4 PT 400146 1 Combination valve LP _Invensys 4 PT 400242 1 Combination Valve Nat _Honeywell 4 PT 400246 1 Combination valve LP _Honeywell 5 PT 400070 1 Tubing fryer pilot 10 PT 300031 ea Burner Fr...

Страница 22: ...T 400076 1 Flue top removable 4 tube fryer PT 400077 1 Flue top removable 5 tube fryer 6 PT 400078 1 Flue wrap top removable 3 and 4 tube fryer PT 400079 1 Flue wrap top removable 5 tube fryer not sho...

Страница 23: ...We all recognize however that replacement parts and occasional professional service may be necessary to extend the useful life of this unit When service is needed contact an Authorized Service Agency...

Страница 24: ...ntiguous United States Hawaii and metropolitan areas of Alaska and Canada may vary The following conditions are not covered by warranty Equipment failure relating to improper installation improper uti...