6. Attach the canopy(EE) to the electrical adapter, and secure with the set screws(CC). 

    Track ends must be terminated with end caps or connectors.  

Turn on the power at fuse or circuit box.

ASSEMBLY INSTRUCTIONS (continued)

Questions, problems, missing parts?

Before returning to your retailer, call our customer service at 1-800-887-6326

Monday – Friday 9:00 a.m. – 5:00 p.m. CST  

FIVE-YEAR LIMITED WARRANTY: 

If, during normal use, this PATRIOT LIGHTING   lighting fixture breaks or fails 

due to a defect in material workmanship within five (5) years from the date of original purchase, simply bring this 

lighting fixture with the original sales receipt back to your nearest MENARDS   retail store. At its discretion, PATRIOT 

LIGHTING   agrees to have the product or any defective part(s) repaired or replaced with the same or similar PATRIOT 

LIGHTING   product or part free of charge, within the stated warranty period, when returned by the original purchaser 

with original sales receipt. This warranty; (1) excludes expendable parts including but not limited to light bulbs; (2) does

not cover damage that has resulted from abuse or misuse; and (3) does not cover any losses, labor, injuries to 

persons/property or costs. This warranty does give you specific legal rights and you may have other rights, which vary

from state to state.

R

R

R

R

 To clean, turn off and wipe with a damp, non-abrasive cloth.

1) The light does not come on at all:

     a)  Check for loosen or disconnected wires in spot light.

     b)  Check that the connection between the adapter and the track is correct.

If unable to fix any of the above issues, please consult a certified electrician.

CARE AND MAINTENANCE

TROUBLESHOOTING

6

4b

Cement Ceiling

Anchor

Track 

Track Screw

    b. For cement ceiling:

        Attach the track to the mounting bracket by aligning predrilled holes. 

        Insert the anchors through the holes of the ceiling, and then attach the

        track screws through the holes of the track, and secure the track screws

        to the anchors. 

    

End cap

Electrical 

Adapter

EE

CC

5

   

Polarity Tab

Track

 

Positive Polarity Slot

Electrical Adapter

   

Neutral

Ground tab

Hot contact conductor

Hot 

Contact

Neutral 

Contact

Ground 

Contact

5. Insert electrical adapter into the 

    track. Rotate adapter 90° to 

    achieve a locked position and to

    make electrical contact. 

    

Note: Make certain polarity tab 

    on the electrical adapter is 

    pointed to the positive polarity 

    slot of the track during 

    installation.