-21 -          

PATON

 MultiPRO

 DC MMA/TIG/MIG/MAG

 

Button 

4

 on the front panel of the unit is responsible for selecting the welding mode.  

 
Buttons 

2

 on the front panel of the source are responsible for changing the current value on the digital indicator on the left. 

 
Buttons 

11 

on the front panel of the feeder are responsible for changing the current value on the digital indicator on the right. 

 

SWITCHING TO THE REQUIRED FUNCTION  

If the unit has a system of protection against unauthorized access to the function menu, then if you press button 

3

 on the source, no changes 

are made on the left indicator, i.e., this button is locked. To unlock, hold it down for more than 3.5 seconds. When unlocking, the indicator 
displays an image of opening locks, indicating the process of unlocking the function menu. After successful unlocking, by pressing button 

3

the current name of the function and its value are displayed on the digital display.  

 
Caution!

 After releasing button 

3

 after 2 seconds, the screen will return to the main parameter of the current welding mode. While the display 

is showing the current function, its value can be changed up or down using buttons 

2

. Alternatively, by quickly pressing and releasing button 

3

, you can switch to the next function, in a circle. 

 
Caution!

 If you hold down button

 3

 for more than 10 seconds, then the countdown will appear on the display 333... 222... 111 ...; release the 

button before this time expires, so as not to reset all the settings of this mode to the standard factory settings. 
 
Similarly, by pressing button 

9

, the digital indicator on the right displays the graphic name of the current function of the wire feeder, and 

immediately  after  releasing  it,  the  current  value  of  this  function  is  displayed  for  2  seconds.  You  can  change  the  value  up  or  down  with 
buttons 

11

 

SWITCHING TO THE REQUIRED WELDING MODE  

Pressing button 

4

 leads to switching to the next welding mode in a circle, this can be seen on display

 1

 on the front panel. 

 

RESET ALL FUNCTIONS OF THE WELDING MODE USED 

Situations may occur when the unit's settings have somewhat confused the user. In order to reset their values to the factory default, use the 
same  button 

3

, used  to  enter  the  function  menu.  To  reset  the  settings,  simply  hold  down button 

3

  for more  than  10  seconds  (ignore  the 

animation of locks). The scoreboard will start counting down 333...222...111 and when "000" is reached, all settings of the current welding 
mode  will  be  updated  to  factory  settings.  Resetting  parameters  for  each  welding  mode  is  performed  separately!  This  is  provided  for 
convenience, so as not to accidentally reset individual settings in the other two modes.  
 
Similarly, you can reset the parameters on the wire feeder using button 

9

 

CHANGE PROGRAM NUMBER IN CURRENT WELDING MODE 

In each MMA, TIG, and MIG / MAG welding mode, it is possible for the user to save up to 16 different presets. The current preset (program) 
number is displayed in the upper right corner of the LCD of the source on the front panel. At the moment of the first  switching on of the 
machine, the program is always under No. 1 for each welding mode. All changes in the setting of the machine in this welding m ode and the 
current program number are saved. To switch to another program number and start setting again from the basic parameters, just press button 

3

 and if the function selection menu is locked, then the LCD displays the current program number, which can be changed up or do wn using 

buttons 

2

.  If  the  function  selection  menu  is  not  locked,  for  example,  the  user  just  before  that  changed  the  additional  parameters  of  the 

functions, then it is necessary to lock the function selection menu by holding button 

3

 for more than 3.5 seconds, in the same way as when 

unlocking, when the LCD will show closing locks, after this operation the menu will be locked and now you can try again to change the program 
number using button 

3

. In this case, all the parameters of the previous program will be saved and you can always return to it again. 

 

GENERAL LIST AND SEQUENCE OF FUNCTIONS 
 
MMA welding mode

 

0) [- 1 -] - main displayed parameter CURRENT = 90A (by default) 

a) 12 ... 25

0А (change step 1А) for 

MultiPRO-250 

b) 12 ... 27

0А (change step 1А) for 

MultiPRO-270 

c) 1

4 ... 350А (change step 1А) for

 MultiPRO-350 

1) [H.St] Hot start power = 40% (by default) 

 

a) 0[OFF] ... 100% (change step 5%) 

2) [t.HS] Hot start time = 0.3 sec (by default) 
  

a) 0.1 ... 1.0 sec (change step 0.1 sec) 

3) [Ar.F] Arc Force power = 40% (by default) 
  

a) 0[OFF] ... 100% (change step 5%) 

4) [u.AF] Arc force trigger level = 12V (by default) 
  

a) 9 ... 18V (change step 1V) 

5) [CVS] current-voltage characteristic slope = 1.4 V/A (by default) 
  

a) 0.2 ... 1.8 V/A (step change 0.4 V/A) 

6) [Sh.A] short arc welding = OFF (by default) 
  

a) ON 

 enabled 

  

b) OFF 

 disabled 

Содержание MultiPRO-250

Страница 1: ......

Страница 2: ...ION Before using the equipment we recommend you to read the extended version of the operating manual by the link https paton ua files passports MultiPRO_GEN pdf Multiprocess welding inverter PATON Mul...

Страница 3: ...3 PATON MultiPRO DC MMA TIG MIG MAG UKRAINE DIN 9 10 85 8...

Страница 4: ...PATON MultiPRO DC MMA TIG MIG MAG 4 ABICOR BINZEL 3 ABICOR BINZEL 3 ABICOR BINZEL 3 ABICOR BINZEL 4...

Страница 5: ...ltiPRO DC MMA TIG MIG MAG 1 2 MMA TIG MIG MAG 3 4 MMA TIG MIG MAG 5 6 7 8 2 4 4 9 10 11 12 KZ 2 13 14 TIG 15 TIG 16 17 18 19 MIG MAG 20 21 22 23 TIG 24 25 26 36V MMA TIG MIG MAG MIG MAG B MMA TIG MIG...

Страница 6: ...O 270 350 15 4 400V 1 2 270 MultiPRO 250 450 MultiPRO 270 350 15 4 400V MMA TIG MIG MAG 1x220V MultiPRO 250 2 80 0 6 1 75 1 5 115 2 155 2 5 195 4 310 3 120 0 8 1 5 75 2 105 2 5 130 4 205 6 310 4 160 1...

Страница 7: ...V MultiPRO 270 400V MultiPRO 350 400V 2 80 0 6 1 0 135 1 5 205 2 270 2 5 340 4 540 3 120 0 8 1 5 135 2 175 2 5 220 4 350 6 525 4 160 1 0 2 130 2 5 160 4 260 6 385 5 220 2 5 115 4 180 6 270 6 270 1 2 2...

Страница 8: ...C MMA TIG MIG MAG 8 100 2 9 10 2 1 10 3 14 16 2 1 16 160 2 9 16 2 1 16 3 14 25 2 1 25 200 2 7 16 2 1 16 3 10 25 2 1 25 250 2 8 25 2 1 25 3 12 35 2 1 35 270 5 11 35 2 1 35 350 6 14 35 2 1 35 TIG TIG LI...

Страница 9: ...00 225A 70 350 100 290A 160 260 15 15 12 250 12 270 14 350 12 28 12 29 12 30 1 6 6 0 1 6 6 0 1 6 6 0 0 6 1 2 0 6 1 2 0 6 1 4 4 15 15 15 MMA 0 2 500 TIG 0 2 500 MIG MAG 5 500 MMA 0 2 500 TIG 0 2 500 MI...

Страница 10: ...PATON MultiPRO DC MMA TIG MIG MAG 10 1 MMA 2 TIG 3 MIG MAG MIG MAG 8 MIG MAG 3 9 MIG MAG 4 2 11 3 3 5 3 3 2 2 3 3 10 333 222 111 9 2 11 3 5 4 1 3 10 333 222 111 000 9 MMA TIG MIG MAG 16 1 3 2 3 3 5...

Страница 11: ...ultiPRO 250 12 270 1 MultiPRO 270 14 350 1 MultiPRO 350 10 I PS 90 a 12 250 1 MultiPRO 250 12 270 1 MultiPRO 270 14 350 1 MultiPRO 350 11 Fr P 5 0 a 0 2 500 0 1 1 12 dut 50 a 20 80 5 TIG 0 2 100 a 12...

Страница 12: ...50 12 29 0V 1 MultiPRO 270 12 30 0V 1 MultiPRO 350 1 But 2T 2T 2 4T 4 4T 4 2 Ind OFF 0 OFF 6 1 3 t Pr 0 1 0 1 25 0 0 1 4 t P0 1 5 a 0 1 25 0 0 1 5 t uP OFF a 0 OFF 5 0 0 1 6 t dn 0 1 a 0 1 5 0 0 1 7 P...

Страница 13: ...13 PATON MultiPRO DC MMA TIG MIG MAG 4 t P0 1 5 a 0 1 25 0 0 1 5 t uP 0 1 a 0 OFF 5 0 0 1 6 t dn OFF a 0 OFF 5 0 0 1 PATON MultiPRO 250 3 MultiPRO 270 400V MultiPRO 350 400V...

Страница 14: ...with a tinted filter should always be worn goggles must be equipped with goggles with a DIN 9 10 filter Unauthorized persons in the operating area of the device must protect their eyes with special g...

Страница 15: ...ry set of the device includes CONTROL ELEMENTS AND INDICATION Operating manual Welding arc power source with wire feeder Semi automatic torch ABICOR BINZEL Rollers for solid and aluminium2 wire Quick...

Страница 16: ...for threading a welding wire 19 Shielding gas connection MIG MAG welding 20 Connector for the control cable from the wire feeder 21 Breaker button for turning on off the machine 22 Wire coil holder w...

Страница 17: ...tries Caution When the unit is connected to a mains voltage higher than 270V for MultiPRO 250 or 450V for MultiPRO 270 350 15 4 400V models all manufacturer s warranty obligations become invalid The m...

Страница 18: ...mm no more than 160 no more than 1 0 mm 2 130 2 5 160 4 260 6 385 5 mm no more than 220 2 5 115 4 180 6 270 6 mm fusible no more than 270 no more than 1 2 mm 2 5 85 4 135 6 205 6 mm up to 350 no more...

Страница 19: ...mm2 G 1 16 3 14 m 25 mm2 G 1 25 not more than 200 2 7 m 16 mm2 G 1 16 3 10 m 25 mm2 G 1 25 not more than 250 2 8 m 25 mm2 G 1 25 3 12 m 35 mm2 G 1 35 not more than 270 5 11 m 35 mm2 G 1 35 up to 350...

Страница 20: ...V 110 Rated consumption power kVA 6 6 7 8 8 0 9 4 10 7 12 3 Maximum power consumption kVA 9 5 11 4 15 3 Efficiency 90 Cooling Adaptive Operating temperature range 25 45 Overall dimensions mm length wi...

Страница 21: ...down button 3 for more than 10 seconds ignore the animation of locks The scoreboard will start counting down 333 222 111 and when 000 is reached all settings of the current welding mode will be updat...

Страница 22: ...me 3 sec by default a 1 0 25 0 sec change step 0 1 sec 4 Pr A current preliminary pilot arc 15 by default a 12 40 change step 1 for MultiPRO 250 12 40 change step 1 for MultiPRO 270 14 40 change step...

Страница 23: ...change step 0 1V for MultiPRO 350 10 Fr P voltage pulsation frequency 20Hz by default a 5 500 Hz step change 1 Hz 11 dut pulse rate duty cycle it is the percentage of the voltage pulse to the period...

Страница 24: ...quipment of heavy objects falling out of buttons and connectors with traces of corrosion which caused a malfunction out of order due to exposure to its power and electronic elements of abundant moistu...

Страница 25: ...____________ Cause ____________________________________________________________________________________________________ ________________________________________________________________________________...

Страница 26: ...___________ Cause ____________________________________________________________________________________________________ _________________________________________________________________________________...