-21 -
PATON
MultiPRO
DC MMA/TIG/MIG/MAG
Button
4
on the front panel of the unit is responsible for selecting the welding mode.
Buttons
2
on the front panel of the source are responsible for changing the current value on the digital indicator on the left.
Buttons
11
on the front panel of the feeder are responsible for changing the current value on the digital indicator on the right.
SWITCHING TO THE REQUIRED FUNCTION
If the unit has a system of protection against unauthorized access to the function menu, then if you press button
3
on the source, no changes
are made on the left indicator, i.e., this button is locked. To unlock, hold it down for more than 3.5 seconds. When unlocking, the indicator
displays an image of opening locks, indicating the process of unlocking the function menu. After successful unlocking, by pressing button
3
,
the current name of the function and its value are displayed on the digital display.
Caution!
After releasing button
3
after 2 seconds, the screen will return to the main parameter of the current welding mode. While the display
is showing the current function, its value can be changed up or down using buttons
2
. Alternatively, by quickly pressing and releasing button
3
, you can switch to the next function, in a circle.
Caution!
If you hold down button
3
for more than 10 seconds, then the countdown will appear on the display 333... 222... 111 ...; release the
button before this time expires, so as not to reset all the settings of this mode to the standard factory settings.
Similarly, by pressing button
9
, the digital indicator on the right displays the graphic name of the current function of the wire feeder, and
immediately after releasing it, the current value of this function is displayed for 2 seconds. You can change the value up or down with
buttons
11
.
SWITCHING TO THE REQUIRED WELDING MODE
Pressing button
4
leads to switching to the next welding mode in a circle, this can be seen on display
1
on the front panel.
RESET ALL FUNCTIONS OF THE WELDING MODE USED
Situations may occur when the unit's settings have somewhat confused the user. In order to reset their values to the factory default, use the
same button
3
, used to enter the function menu. To reset the settings, simply hold down button
3
for more than 10 seconds (ignore the
animation of locks). The scoreboard will start counting down 333...222...111 and when "000" is reached, all settings of the current welding
mode will be updated to factory settings. Resetting parameters for each welding mode is performed separately! This is provided for
convenience, so as not to accidentally reset individual settings in the other two modes.
Similarly, you can reset the parameters on the wire feeder using button
9
.
CHANGE PROGRAM NUMBER IN CURRENT WELDING MODE
In each MMA, TIG, and MIG / MAG welding mode, it is possible for the user to save up to 16 different presets. The current preset (program)
number is displayed in the upper right corner of the LCD of the source on the front panel. At the moment of the first switching on of the
machine, the program is always under No. 1 for each welding mode. All changes in the setting of the machine in this welding m ode and the
current program number are saved. To switch to another program number and start setting again from the basic parameters, just press button
3
and if the function selection menu is locked, then the LCD displays the current program number, which can be changed up or do wn using
buttons
2
. If the function selection menu is not locked, for example, the user just before that changed the additional parameters of the
functions, then it is necessary to lock the function selection menu by holding button
3
for more than 3.5 seconds, in the same way as when
unlocking, when the LCD will show closing locks, after this operation the menu will be locked and now you can try again to change the program
number using button
3
. In this case, all the parameters of the previous program will be saved and you can always return to it again.
GENERAL LIST AND SEQUENCE OF FUNCTIONS
MMA welding mode
0) [- 1 -] - main displayed parameter CURRENT = 90A (by default)
a) 12 ... 25
0А (change step 1А) for
MultiPRO-250
b) 12 ... 27
0А (change step 1А) for
MultiPRO-270
c) 1
4 ... 350А (change step 1А) for
MultiPRO-350
1) [H.St] Hot start power = 40% (by default)
a) 0[OFF] ... 100% (change step 5%)
2) [t.HS] Hot start time = 0.3 sec (by default)
a) 0.1 ... 1.0 sec (change step 0.1 sec)
3) [Ar.F] Arc Force power = 40% (by default)
a) 0[OFF] ... 100% (change step 5%)
4) [u.AF] Arc force trigger level = 12V (by default)
a) 9 ... 18V (change step 1V)
5) [CVS] current-voltage characteristic slope = 1.4 V/A (by default)
a) 0.2 ... 1.8 V/A (step change 0.4 V/A)
6) [Sh.A] short arc welding = OFF (by default)
a) ON
–
enabled
b) OFF
–
disabled