16
Wireless Data Communication System - WD PRO Series Instruction Manual
5. Operation Overview
5.5 Function List
5.5.1 LED Unit and Buzzer Unit Control Functions
Runs control of LED and buzzer units connected to WDT-PRO. There are two types: Control based on the Signal
Tower control line, and remote control from the host.
Function
Description
References
Signal Tower Control
Functions
Functions that control LED or buzzer
units with the Signal Tower control line.
☞ 8.1.1.Signal Tower Control Functions(P.45)
Remote Control
Functions
Functions that perform remote control
of LED or buzzer units from the host.
☞ 8.1.2 Remote Control Functions(P.46)
Release Remote Control
Functions
Function that enables operation
transition from Remote Control
Function to Signal Tower Control
Function.
☞ 8.1.3 Release Remote Control Function(P.47)
5.5.2 Contact Input Line Functions
Determines the input status of the Signal Tower control line, external input line, and clear input line.
Function
Description
References
Determine Signal Tower
Control Input Function
Function for determining the signal
input status of the Signal Tower control
line.
☞ 8.2.1 Determine Signal Tower Control Input
Determine External Input
Line Function
Function to detect changes in state of
8 external input lines and to save that
information.
☞ 8.2.2 Determine External Input Line
Determine Simultaneous
Input Function
Function to set the sensitivity for
determining simultaneous input on the
Signal Tower control line and external
input line.
☞ 8.2.3 Function to Determine Simultaneous
Input of Signal Tower Control Line and
External Input Line(P.51)
Determine Clear Input
Line Function
Function to detect inputs on the clear
input line and to save that information.
Detects when the clear input line
changes from OFF to ON.
☞ 8.2.4 Determine Clear Input Line
Simple Counter Function
Function for saving the accumulated
value (counter value) of pulse inputs
(incremented 1 at a time) on a signal
wire.
☞ 8.2.5 Simple Counter Function(P.52)
5.5.3 RS-232C Communication Functions
Runs communication with external equipment, such as a bar code reader, through the RS-232C interface.
Function
Description
References
Communication Setup
Function
Function to set up RS-232C
communication.
☞ 8.3.1 Communication Setup Function(P.53)
Receive Data Function
Function for receiving data transmitted
by external equipment, following the
receive data file format settings.
☞ 8.3.2 Receive Data Function(P.53)
Transmit Data Function
Function for transmitting to external
equipment data received from the host.