Betriebsanleitung / Operation manual
Ex-d Signalsäule / Ex-d Signal Tower ST-PA-LR6
____________________________________________________________________________________________________________
____________________________________________________________________________________________________________
Version LR6 07/2018 Seite/page 22/30
9. Technical Data
Material:
Aluminium - grey lacquered, Borosilicate glass
Sealing:
Nitrile O-Ring
IP-Protection:
IP66
Cable glands:
You have to use special approved cable glands or line
bushings with protection type „Ex-d“, according actual
standards.
Holes for cable entries which are not used shall be closed
by Ex-d certified blind plugs of protection IP 66.
Please ask Quintex for suitable cable glands or ready
configured line bushings.
Extension of glands by drilling new holes is explicit not
permitted!
Terminal:
According type 3…10 pole, each 2x 0,5..2,5mm²
Cage clamp technology
Nominal voltage:
pls. see type label
Nominal current:
pls. see type label
Ambient temperature range:
-20...+50°C
Storage temperature range:
-30...+60°C
Mounting position:
Vertical or horizontal
Data of Modules:
Steady light 24V DC: I=0,04A
Steady light 110-240V AC: I=0,04A
For detailed data pls. see Datasheet or Manual of Patlite
Type LR6
For additional information please read EC-Type Examination Certificate and corresponding
data sheets.