Patlite PHE-3FB3 Скачать руководство пользователя страница 8

8

2.2.  RS-232C Port Wiring

By connecting the RS-232C (male) of this product to an RS-232C port of a PC with a D-sub 9 pin female-to-
female type cable with a straight wire connection, this product can be controlled via RS-232C transmission.

 

 

*The RS-232C cable is not included.  Please purchase it separately.

Connect the cables with the connection pin numbers listed below.  The pin numbers not showing will not affect the 
operation of this product.

  Caution

• Do not bundle the RS-232C cable with power supply cords when being used.  Failure to comply may 

result in malfunction from power line noise.

• Do not connect the RS-232C cables simultaneously.Failure to comply may result in malfunction.

• Please use the RS-232C cable and USB cable one - to - one with the port of the connected equipment 

(PC etc.). When used in conjunction with other equipment, malfunction may occur, and the main unit 

and connected equipment may be damaged.

2

PHE-3FB3-RYG

Control Device

(PC)

D-sub 9 pin female

inch threading

D-sub 9 pin female

inch threading

1

6

9

5

1

6

9

5

Signal

Pin No.

Pin No. Signal

TXD

2

2

RXD

RXD

3

3

TXD

GND

5

5

GND

CTS

7

7

RTS

RTS

8

8

CTS

Содержание PHE-3FB3

Страница 1: ...T95100260_03 PHE 3FB3 RYG User s Manual Interface Converter For Models PHE 3FB3 RYG PHE 3FB3N RYG...

Страница 2: ...2 5 Buzzer Switch 10 2 6 Volume adjustment 11 2 7 Clear Switch 12 2 8 Power Activation 12 2 9 About AC Adaptor 13 3 Communication Specifications 14 3 1 Communication Set Up 14 3 2 Normal Operation Mo...

Страница 3: ...our company Any reproduction duplication alteration or extracting portions of this book etc without written permission from our company is forbidden Specifications the design and other contents writte...

Страница 4: ...tely By allowing dust to adhere it can be the result of fire or failure from short circuiting Since dust can accumulate After a long time and with moisture can cause the dust to become conductive in o...

Страница 5: ...Unit Number Name 1 Buzzer Unit 2 Red Unit 3 Amber Unit 4 Green Unit 5 Clear Switch 6 Set Switch 7 Buzzer Switch 8 USB Port Type B 9 RS 232C Port D sub 9 pin male 10 Power LED 11 DC Jack 1 2 2 AC Adap...

Страница 6: ...6 1 3 Outer Dimensional Drawing 1 3 1 Main Unit 1 3 2 AC Adaptor 1 Unit mm Unit mm 74mm 1530mm 4 3 5 mm 3 5 3 mm OD5 5mm ID2 1mm 24VDC 1A Unit mm 281 5 253 5 117 100 40...

Страница 7: ...ng in damage When installing this product avoid installating it in the following places Where it s exposed to direct sunlight Where high temperatures are present such as near fire or in a humid place...

Страница 8: ...ndle the RS 232C cable with power supply cords when being used Failure to comply may result in malfunction from power line noise Do not connect the RS 232C cables simultaneously Failure to comply may...

Страница 9: ...er supply cords when being used Failure to comply may result in malfunction from power line noise Depending on the feeding power capability of the Main Unit or the USB port of the personal computer op...

Страница 10: ...nload the instructions from Patlite s home page and check the manual 2 5 Buzzer Switch It is possible to adjust ON or OFF by moving the buzzer switch left and right MEMO If it is set to OFF the buzzer...

Страница 11: ...ing the DIP switch in the buzzer unit To sound reduction please turn on DIP switches 1 and 3 as shown below DIP Switch When down it is ON Switch is shown by DIP Switch When down it is ON Switch is sho...

Страница 12: ...ing it directly do not use a USB hub Failure to do so may cause unstable operation MEMO When operating with USB bus power the LED units get dark All output terminals for this product can be turned OFF...

Страница 13: ...ction could result in fire or product failure Use the AC adaptor included in the product To order an AC adaptor separately purchase our AC adaptor ADP 001 When using N model AC Adaptor not included an...

Страница 14: ...execution of commands irrespective of the main unit ID 3 2 1 1 Comand List The list of commands and functions which can be used is shown in the table below Command Number of Data Bytes Function ASCII...

Страница 15: ...Data NAK 15H The following are conditions in which will get a NAK reply and the error contents are as follows Transmission Condition Error Contents Command Error When commands other than a command fro...

Страница 16: ...ly Data Normal Response Data ACK 06H Response Error Data NAK 15H The following are conditions in which will get a NAK reply and the error contents are as follows Transmission Condition Error Contents...

Страница 17: ...3FH 2 32H 1 31H 21H Reply Data Normal Response Data ACK 06H Response Error Data NAK 15H The following are conditions in which will get a NAK reply and the error contents are as follows Transmission C...

Страница 18: ...39H No Change in Conditon 2 This value is undefined 3 List of specified data for buzzer Command Function ASCII Hex 0 30H Mutes the Buzzer 1 31H Turns on Buzzer Pattern 1 2 32H Turns on Buzzer Pattern...

Страница 19: ...Signal Tower Lighting is turned on 2 32H Signal Tower Flashing Pattern 1 is turned on 3 33H Signal Tower Flashing Pattern 2 is turned on 9 39H No Change in Conditon 2 List of reply data for buzzer Co...

Страница 20: ...Normal Response Data ACK 06H Response Error Data NAK 15H The following are conditions in which will get a NAK reply and the error contents are as follows Transmission Condition Error Contents Command...

Страница 21: ...Hex 0 30H Signal Tower Lighting is turned off 1 31H Signal Tower Lighting is turned on 2 32H Signal Tower Flashing Pattern 1 is turned on 3 33H Signal Tower Flashing Pattern 2 is turned on 9 39H No C...

Страница 22: ...FF ON OFF ON OFF ON OFF 3 3 2 Buzzer Pattern Four kind of buzzer sounds such as Buzzer pattern 1 Buzzer pattern 2 Buzzer pattern3 and Buzzer pattern4 are available to distinguish a variety of conditio...

Страница 23: ...are for the Signal Tower lighting control Transmission Example In this example the Signal Tower red and green are switched on and the amber is turned off Send Data Data HEX Code 05H Byte Count 1Byte...

Страница 24: ...ssories Option Operating portion Clear Switch Set Switch Buzzer Switch AC Adaptor 1 Installation Manual Ruber feet 4 pcs Sound Reduction sheet Tint Film NHP TF Condition Outer Dimensions Refer to the...

Страница 25: ...ure gets inside the product it can cause short circuiting electric shock or fire Periodically remove dust from the electric socket to prevent a fire hazard By allowing dust to adhere to the power supp...

Страница 26: ...p by volatile medicine and a chemical dustcloth of a benzine and a paint thinner It may cause deformation or product failure Be careful as the LED unit can not be removed if Tint Film is pasted across...

Страница 27: ...ste Partly overlap Finish Peel off the release paper 2 places of double sided tape Please paste Tint Film by the following procedure Parts Model LED Unit red LR4 E RZ LED Unit Amber LR4 E YZ LED Unit...

Страница 28: ...Tower Body Buzzer unit Main Body Attach adjacent units one by one in order from the bottom in order Caution Do not apply excessive strength with each unit or body Failure to comply may damage the uni...

Страница 29: ...the tab fits in the groove Attach the LED Unit to the product 40 Tab Groove Buzzer Unit Underside View Turn the internal part of the Buzzer Unit counterclockwise until the tab fits in the groove Atta...

Страница 30: ...may be dark in operation with USB bus power Refer to 2 7 Power Activation The Signal Tower is not turned on Make sure that setting switch is in Normal Operation Mode or PHU Compatibility Mode Refer to...

Страница 31: ......

Отзывы: