– 4 –
4
Installation
Notice
The following requirements are necessary for a proper mounting location.
- Location with
strong
and
even surface
with
minimal vibration
.
Install with the mounting direction in the
upright position
.
When the installation location is unavoidably irregular and waterproof performance is required, use a sealant between
the product and the installation surface.
Basic Mounting Instructions
1
Make holes for the mounting and wire-distribution for the product.
(Check the Model and refer to the suitable mounting dimension
fi
gure.)
2
Connect to the product through the distribution hole.
3
Secure the product with the nuts.
WM WC Installation Figure (M12 Connector Installation Figure)
Connect to the M12
Connector through the
distribution hole.
Body
M12 Bracket
Direct Mount Bracket
1
2
1
Connect cabel
to the M12
Connector.
2
Turn the
connected
cable in the
direction of the
arrow.
WM Mounting Dimensional Drawing
(Unit: mm)
120°
120°
ĭ
40
Wire Distribution Hole
(
Φ
20)
Nameplate
Position
Mounting Hole
(3 places)
Screw/
Nut
Φ
5
M4
Recommended Torque
0.6 N·m