background image

Pathway Connectivity 
Quattro Manual 
September 2014 

8

 

Protocol Support

 

Property 

Explanation 

Available Settings 

 

 

 

Art-Net Rx (receive) 

Set node to listen for Artnet 

Enable (default) 
Disable 

sACN Rx (receive) 

Set node to listen for sACN 

Enable (default) 
Disable 

Shownet Rx (receive) 

Set node to listen for Shownet 

Enable (default) 
Disable 

Pathport Rx (receive) 

Set node to listen for Pathport 

Enable (default) 
Disable 

Tx Data Protocol (send) 

Choose transmit protocol 

Artnet 
sACN 
Shownet 
Pathport (default) 

<Back> 

 

 

Utilities

 

Property 

Explanation 

Available Settings 

 

 

 

Reboot 

Power cycle the node 

 

Factory Default 

Resets patches and all 
properties except the IP 
settings to factory values.  
Includes properties, such as 
signal loss, that are set from 
Pathport Manager. 

 

Factory Default Including 
Network Setup  

Resets patches and all 
properties including the IP 
settings to factory values.  
Includes properties, such as 
signal loss, that are set from 
Pathport Manager. 

 

<Back> 

 

 

 

Note Regarding ArtNet, Shownet and Subnet Mask 

The ArtNet protocol is explicitly sent to a broadcast address, typically 
2.255.255.255 or 10.255.255.255.  The Quattro must have its subnet mask set 
wide enough to include this broadcast address.  When using ArtNet, a Class A 
subnet mask of 255.0.0.0 is recommended to ensure DMX output. 
 

Shownet is explicitly sent to 192.168.1.255.  On a Shownet system, a 

Quattro should use an IP of 192.168.1.x and a subnet mask of 255.255.255.0. 
 
 

Содержание Pathport QUATTRO

Страница 1: ...hport QUATTRO User Guide September 2014 For firmware 3 6 0 0 and higher 2011 Pathway Connectivity a Division of Acuity Brands Canada 1439 17 Ave SE Calgary AB T2G 1J9 403 243 8110 www pathwayconnect c...

Страница 2: ...ntents About Pathport Quattro 3 Installation Instructions 3 Protocols Supported 4 Front Panel Controls 5 Rear Panel 5 Front Panel Display 6 Setting Node Properties 7 Note Regarding ArtNet Shownet and...

Страница 3: ...X sources are treated merged or prioritized and certain other routing characteristics including DMX transmission speed and signal loss behavior Installation Instructions The Pathport Quattro is intend...

Страница 4: ...as made in popular with media server manufacturers Because this is not a standard some implementations may not work with others Strand Shownet A proprietary broadcast protocol developed by Strand Ligh...

Страница 5: ...lashing Steady On OUTPUT GREEN Port Active Patched BLUE Steady On Quattro DMX RDM GATEWAY DMX RDM INPUT OUTPUT PORT POWER A B C D Off Port Disabled Rear Panel Port A Port C Port D Port B ACTIVITY 10 1...

Страница 6: ...the rear panel EtherCon port If no soft label name has been assigned to the node the IP address will be shown on the top line as well as the middle The subnet class shown after the IP on the middle l...

Страница 7: ...rty Explanation Available Settings IP Address Set IP address for node Select then turn knob to set each octet Push to accept Subnet Mask Set subnet mask for node Select then turn knob to set each octe...

Страница 8: ...all properties except the IP settings to factory values Includes properties such as signal loss that are set from Pathport Manager Factory Default Including Network Setup Resets patches and all prope...

Страница 9: ...options may be added from time to time Property Explanation Available Settings DMX Port Turns blue power light on off Enable default Disable Port Direction Sets DMX direction for port Input Output de...