Troubleshooting Flow Charts
23
PROBLEM: The lever lockout system of the crane is activated. Crane movements “hoist up”, “telescope
out”, and “boom down” are stopped. Crane is not in overload or two -block condition.
Lever Lockout Activated
Start
Set the override key switch in central unit into upper position to override
Fixed
YES
NO
Does console indicate Anti-Two-block warning?
NO
Yes
Fault in crane electric
or hydraulic system.
If console display is
blank fault is located in
power supply, wiring or
fuses .
Fault in Anti-Two
Block system.
If Load Moment Limit Light
displays fault, it is located in
LMI, cables, wiring, fuses, or
console.
Check lever lockout
system in crane.
Go to Flow Chart 4
Go to Flow Chart 5
Read error code displayed
on console and go to
Section 6.
Содержание DS 150
Страница 2: ......
Страница 3: ......
Страница 5: ...Service Manual DS150...
Страница 7: ...Service Manual DS150...
Страница 10: ...Mechanical Description Of The System 3 Basic System Component Layout...
Страница 13: ...Drawings 6 4 DRAWINGS SYSTEM Electrical Diagram...
Страница 14: ...Drawings 7 Central Unit 024 150 060 002 Spare Parts List...
Страница 20: ...Drawings 13 4 5 Cable Reel 068 208 060 013 LWG208 Spare Parts List...
Страница 24: ...Procedures 17 Length Angle Adjustments...
Страница 26: ...Theory 19 6 THEORY Anti Two Block Shutoff Circuit Length Measuring Channel...
Страница 27: ...Theory 20 Piston Side Pressure Measuring Channel Rod Side Pressure Measuring Channel...
Страница 28: ...Theory 21 Main Boom Angle Measuring Channel Second Angle Measuring Channel...
Страница 53: ...Error Codes 46 America Inc service department...