Setup:

Please read and understand the operational instructions and safety issues associated with 

this product.  We go through great effort to make a soundly engineered and superbly 

performing product of lasting durability.  If you have any questions we are anxious to assist 

in addressing them.  Do not hesitate to contact either your dealer or the Pass Labs factory 

directly.  We are here to support the product and you the end-user.

As with all things electrical, the power cord should be the last item attached to the pre-amp 

and the very first cable to be removed anytime you hook-up or remove any equipment from 

the signal chain.

The JAE umbilical cable should never be connected or removed without turning the XP-

32 off from the rear panel power switch or by unplugging the AC Power cord.  When 

installing the circular connector on the JAE umbilical, care must be exercised to fully seat 

the connector and bottom the ring nut.  The connectors are keyed and can only go in one 

way. The larger tab goes to the top. The ring nut is provided with a conventional right hand 

thread that should never require any use of force or tools to connect or disconnect the cable 

from either chassis   Clockwise rotation of the ring nut to secure the connector, counter-

clockwise rotation to remove.

The gain channels may be placed in proximity of the power supply control unit (either on 

top of or underneath) with negligible  loss of performance due to the extensive shielding 

afforded the power supply. Some separation of the chassis is however encouraged. The 

umbilical cables as supplied are 1.5m (5ft) in length to allow for convenient component 

placement.

The XP-32 draws roughly 70W of power in operation.  The pre-amplifier’s actual  voltage 

and current rating are indicated on an affixed tag on the rear of the pre-amplifier.   Please 

verify that the indicated voltage requirements of this product are consistent with the 

supplied power at your intended point of use.

We have provided a standard IEC AC power cord that fits into the IEC 320 line receptacle / 

switched inlet module at the rear of the amplifier.  In addition to providing for power cord 

attachment this inlet module additionally incorporates a power switch and fuse holder.  The 

fuse in all cases will be a 5mm x 20mm non re-settable time delay glass fuse.   Proper fuse 

value is indicated on the back of the amp.  

The IEC inlet provides for a safety ground via the AC mains power cord.  In addition 

to safety this ground is necessary for proper noise rejection.  Do not defeat this ground 

connection.

NOTE: the “Overload” and “Time Delay” characteristics of UL and CE rated fuses are 

not identical.  Additionally these characteristics will differ slightly (due to the difference in 

Содержание XP-32

Страница 1: ...1 PASS TM XP 32 Owner s Manual ...

Страница 2: ...roductweurgeyoutochooseonethatis fully safety rated by the necessary local authority Power Cord Protection Power supply cords should be routed so that they are notlikelytobewalkedon abraded orpinchedbyitemsplacedonoragainstthem paying particular attention to cords where they enter plugs or exit from a device Never under any circumstance insert a cut or damaged power cord into a mains power socket ...

Страница 3: ...ower supply dedicated to the control architecture The use of three fully independent power supplies in the control chassis results in dramatically lower radiated noise and far better THD Noise figures in the gain stages Residual circuit noise becomes paramountatlowsignallevels Bygoingtoextremelengthstolowernoiseweenjoy better resolution and dynamics in the music Inthetwogainchassiswecontinuetouseo...

Страница 4: ...els may be placed in proximity of the power supply control unit either on top of or underneath with negligible loss of performance due to the extensive shielding afforded the power supply Some separation of the chassis is however encouraged The umbilical cables as supplied are 1 5m 5ft in length to allow for convenient component placement The XP 32 draws roughly 70W of power in operation The pre a...

Страница 5: ...in output by use of the small volume control knob on the gain channels Once set both main and slave outputs track each other through the main volume controlonthecontrolchassis Havingtwoavailableandrelativelyindependentoutputswith asinglevolumecontrol allowsforbi ampingusingamplifiersofdifferentgainordriversof different sensitivity The output of the Tape loop is at 0dB unity gain output which allow...

Страница 6: ...eforeselectingthehometheaterpassthrough passthruonthehandremote for thefirsttime itisimperativethattheinputdeviceontheHTinputhaveit sgainset to zero Failure to follow this precaution could result in a volume level intolerable tobothearsandspeakers Selectinghometheaterbypass setsthegainofthepre amplifier to 0dB gain of 1x When the Pass Thru function is selected volume control of the system is under...

Страница 7: ... Pressing the increase button or the decrease v button will shift the volumesettinginbothchannelsequallyin0 5steps Holdingeitherbuttondown willincreaseordecreasethelevel untilsuchtimeasyoueitherreleasethebuttonor reach the limits of the volume control PASS THRU Pressing this button once selects the Pass Thru input and displays PASS THRU and swiftly ramps the volume from step 0 to step 179 As a pre...

Страница 8: ...connector on the rear of the XP 32 control chassis This is intendedtosupplyatriggervoltagethatwillturnonassociatedequipmentsuchas poweramps Asperconvention voltageisappliedtothetipcontactand voltage isappliedtothesleevecontract Checktheownersmanualofyourpre amptoseeif this function in compatible The hand remote is powered by 2 each AAA batteries that are housed under the rearcoverofthehandremote B...

Страница 9: ...n North American product must be returned to the country of origin for warranty service ForeigndistributorsareonlyrequiredtoofferwarrantyserviceonPassLaboratories product that they have imported verifiable by serial number Please note Conditions of warranty service and customer rights for product purchased outsidetheUnitedStatesmayvarydependinguponthedistributorandlocallaws Please check with your ...

Страница 10: ... Auburn CA 95602 voice 530 878 5350 fax 530 878 5358 web passlabs com XP 32 Specs Power consumption 70 watts Gain 9 6 dB Balanced Output Impedance 25 Ohms RCA 50 Ohms XLR Input Impedance 22K Ohms Frequency response 0 05 dB 20Hz to 20KHz 2dB 150KHz Crosstalk 110dB THD 0 001 1V 1Khz Max out 23V RMS 0 1 Residual Noise 500nV RMS SN 150dB ref max out Dimensions 17 w x 12 5 d x 4 h times three Weight 62...

Отзывы: