INT-150 Owners Manual

Please check with the factory-authorized distributor in the country you are 
purchasing this product for specific warranty information.

All Pass Laboratories products purchased from an authorized Pass Labora-
tories dealer in North America are covered by a transferable, limited 3-year 
warranty.  This warrantee includes all parts and labor charges incurred at the 
repair facility in addition to return shipping to the domestic customer, exclu-
sive of  subsequent damages.  Damage due to physical abuse is specifically 
not covered under this warranty.

For  this  warranty  to  apply  the  customer  is  responsible  for  returning  the 
product unmodified to the factory within the warranty period. The customer 
assumes all responsibility for shipping and insurance to the factory or a fac-
tory specified repair facility.  The conditions and stipulations of  this Pass 
Laboratories warranty only applies to units sold new in North America.

Non-North America customers should consult with their original Pass Labs 
dealer or distributor for warrantee repair instruction prior to contacting the 
factory or shipping product for repair.  

Non-North American product must be returned to the country of  origin for 
warrantee service.  Foreign distributors are only required to offer warranty 
service on Pass Laboratories product that they have imported.  

Please note: Conditions of  warranty service and customer rights for product 
purchased outside the United States may vary depending upon the distribu-
tor and local laws.  Please check with your local distributor for specific rights 
and details.

Any  modifications  to  Pass  Laboratories  products  that  have  not  received 
written factory approval nullify all claims and void the warrantee.  Should a 
modified product be returned to the factory for repair the owner will be re-
quired to pay all necessary charges for the repair in addition to those charges 
required to return the product to it’s original configuration.

In the case of  safety issues, no product shall be returned to the customer 
without  those  safety  issues  being  corrected  to  the  most  recent  accepted 
standards.

Removal or alteration of  original Pass Labs serial numbers voids the factory 
warranty.  Product with altered or missing serial numbers will be suspected 
as counterfeit product.

Pass Laboratories will not repair or in any way indemnify any counterfeit or 
cloned product.

Pass  Laboratories  does  not  offer  products  in  voltages  intended  for  inter-
national markets either to authorized Pass Labs dealers or to third parties 
located in the United States or Canada.

Warranty Information

Pass Laboratories, PO Box 219, Foresthill, CA  95631  USA, 

 530.367.3690

Содержание INT-150

Страница 1: ...1 INT 150 Owners Manual pass TM INT 150 Owner s Manual Nov 19 2007 ...

Страница 2: ...es a power supply cord that meets all legislated requirements for the market in which the product was originally sold If you choose to substitute an after market product we urge you to choose a polarized cord that is fully safety rated by the necessary local authority Under no circumstances defeat the safety purpose of any polarized plugs If the supplied power cord does not fit your power outlet c...

Страница 3: ...ns All other servicing must be referred to qualified service personnel For Units With Externally Accessible Fuse Receptacle Unplug the device from all sources of power before changing or inspecting any fuse Replace fuse with one of same physical size type and rating as that specified by the manufacture for that product Pass Laboratories PO Box 219 24449 Foresthill Rd Foresthill CA 95631 USA www pa...

Страница 4: ... amplifier the X1000 was intended as the premier example of the power of this principle delivering 1000 watts rms into 8 ohms at low distortion By itself of course this is no miracle but you have to consider that products with comparable performance have complicated circuits with as many as nine consecutive gain stages and lots and lots of negative feedback The X1000 had only two stages and used o...

Страница 5: ...speaker loads without misbehaving and all are unconditionally stable into low impedance and reactive loads All the usual performance metrics power distortion noise input impedance damping factor and bandwidth have all been improved in this latest generation The power supplies are larger with fast rectifiers gating to larger capacitor banks The increases in AC line noise worldwide have been address...

Страница 6: ... such as domestic heaters or open fires Keep all electrical devices away from liquids and liquids away from electrical devices When not actually intending to play music the amplifier should be left in standby mode from the front panel switch where it draws only a few watts of bias on the output stage If you wish to reduce the power draw to 0 you can shut the amplifier off via the rear panel switch...

Страница 7: ...on off 5 Mute momentary push button on off 6 Input selection buttons inputs 1 4 7 IR remote receiver window 8 Volume control A Pre amplifier inputs 1 2 XLR RCA 3 4 RCA B Pre amplifier outputs XLR OR RCA C Right Channel speaker connector D Signal ground connector E IEC 520 AC power inlet module F Main Power switch not a safety disconnect G Fuse holder H Left Channel Speaker connector ...

Страница 8: ...e the RCA input be certain that the XLR connector has a gold shorting plug between pins 1 and 3 which connects the minus input to ground otherwise the amplifier will not operate properly If you lose this shorting plug just contact the factory we give them away all the time The question comes up all the time are balanced inputs XLR better than single ended RCA The answer is that balanced lines gene...

Страница 9: ...ker terminals will be electrically live when the amplifier is on Check to make certain that the loudspeaker cables aren t shorted at the loudspeaker end and then connect speaker cables to the output binding posts on the amplifiers observing correct polarity The output binding posts will accept either bare wire or spades Regulatory agencies in many countries have banned binding posts that will acce...

Страница 10: ...f normal luminance reduced luminance or display off In the display off mode the display will be normally dark yet will provide reduced luminance for several seconds any time a control function on either the remote or integrated amplifier front panel are activated Please note The hand remote is common to several Pass Labs products not all of the functions on this remote are applicable to your integ...

Страница 11: ...ture exceeds 75 degrees Centigrade This thermal cutout should never occur in real life This is a very rare occurrence and would indicate a serious problem We have a general recommendation about interconnects and speaker cables They should cost less than the amplifier and contain at least some conductive material We have tried a lot of products and most work well but as a practical matter we cannot...

Страница 12: ...les but we can say that we have had amplifiers operating in the field in excess of 20 years with no particular mortality and we don t have good information beyond that More to the point you should not worry about it This is a conservatively built industrial design not a frail tube circuit run on the brink of catastrophic failure If it breaks we will simply get it fixed so sleep well INT 150 Specif...

Страница 13: ... Foreign distributors are only required to offer warranty service on Pass Laboratories product that they have imported Please note Conditions of warranty service and customer rights for product purchased outside the United States may vary depending upon the distribu tor and local laws Please check with your local distributor for specific rights and details Any modifications to Pass Laboratories pr...

Отзывы: