background image

8

INT-150 Owners Manual

For maximum safety we suggest that the power cord should be the last 
cable installed on your power-amplifier.  

You may, if  you wish, substitute a 15-amp aftermarket power cord for the 
one we have supplied.  Only use polarized power cords, which meet all 
local safety standards and carry acceptance marks from the local regulatory 
authority.  The power cord should be attached to the amplifier prior to 
plugging into house power.  Always place the rear-mounted switch in the 
off  (down) position before plugging in this amplifier. 

The amplifier’s voltage and current rating are indicated on the rear panel.  
It will be indicated as either 100 volts, 120 volts, 220 volts, 230 volts or 
240 volts.  The smaller Pass Laboratories power amplifiers, preamps 
and integrated amplifiers use a slow-blow 3AG (equivalent to 313 in EC 
markets) type fuse.  The required value of  the fuse will be indicated on 
the amplifier.  The frequency rating of  the AC line source is 50 to 60 
Hz.  Please verify that the amplifiers indicated voltage requirements are 
consistent with the supplied voltage and current at your location.

On the rear panel you will find both RCA and XLR type input connections 
for single-ended or balanced inputs.  If  you use the RCA input, be certain 
that the XLR connector has a gold shorting plug between pins 1 and 3, 
which connects the “minus” input to ground, otherwise the amplifier will 
not operate properly.  If  you lose this shorting plug, just contact the factory 
– we give them away all the time.

The question comes up all the time – are balanced inputs (XLR) better 
than single-ended (RCA)?  The answer is that balanced lines generally give 
lower noise and slightly less distortion.  They are recommended unless your 
favorite source component has only RCA outputs.

Also on the rear panel are the output connections for the loudspeakers.  On 
stereo amplifiers there is one pair per channel, and on mono amplifiers we 
provide two pairs wired in parallel to facilitate “bi-wiring” a loudspeaker.  
As you are probably familiar, the red one is positive polarity, and the black 
one is negative.

Please note that, being a balanced output device, both of  these terminals 
are electrically live – neither is grounded and neither should not be treated 
as ground.  This is particularly important if  you are using the output of  
the amp to also drive a subwoofer amplifier or other active component.  If  
there is any question, please contact the manufacturers of  the products 
involved – both they and we will be happy to advise you.

If  you happen to need a clean signal ground connection for any reason, 
we provide a dedicated 5 way binding post just for that on the rear of  the 
amplifier.

Содержание INT-150

Страница 1: ...1 INT 150 Owners Manual pass TM INT 150 Owner s Manual Nov 19 2007 ...

Страница 2: ...es a power supply cord that meets all legislated requirements for the market in which the product was originally sold If you choose to substitute an after market product we urge you to choose a polarized cord that is fully safety rated by the necessary local authority Under no circumstances defeat the safety purpose of any polarized plugs If the supplied power cord does not fit your power outlet c...

Страница 3: ...ns All other servicing must be referred to qualified service personnel For Units With Externally Accessible Fuse Receptacle Unplug the device from all sources of power before changing or inspecting any fuse Replace fuse with one of same physical size type and rating as that specified by the manufacture for that product Pass Laboratories PO Box 219 24449 Foresthill Rd Foresthill CA 95631 USA www pa...

Страница 4: ... amplifier the X1000 was intended as the premier example of the power of this principle delivering 1000 watts rms into 8 ohms at low distortion By itself of course this is no miracle but you have to consider that products with comparable performance have complicated circuits with as many as nine consecutive gain stages and lots and lots of negative feedback The X1000 had only two stages and used o...

Страница 5: ...speaker loads without misbehaving and all are unconditionally stable into low impedance and reactive loads All the usual performance metrics power distortion noise input impedance damping factor and bandwidth have all been improved in this latest generation The power supplies are larger with fast rectifiers gating to larger capacitor banks The increases in AC line noise worldwide have been address...

Страница 6: ... such as domestic heaters or open fires Keep all electrical devices away from liquids and liquids away from electrical devices When not actually intending to play music the amplifier should be left in standby mode from the front panel switch where it draws only a few watts of bias on the output stage If you wish to reduce the power draw to 0 you can shut the amplifier off via the rear panel switch...

Страница 7: ...on off 5 Mute momentary push button on off 6 Input selection buttons inputs 1 4 7 IR remote receiver window 8 Volume control A Pre amplifier inputs 1 2 XLR RCA 3 4 RCA B Pre amplifier outputs XLR OR RCA C Right Channel speaker connector D Signal ground connector E IEC 520 AC power inlet module F Main Power switch not a safety disconnect G Fuse holder H Left Channel Speaker connector ...

Страница 8: ...e the RCA input be certain that the XLR connector has a gold shorting plug between pins 1 and 3 which connects the minus input to ground otherwise the amplifier will not operate properly If you lose this shorting plug just contact the factory we give them away all the time The question comes up all the time are balanced inputs XLR better than single ended RCA The answer is that balanced lines gene...

Страница 9: ...ker terminals will be electrically live when the amplifier is on Check to make certain that the loudspeaker cables aren t shorted at the loudspeaker end and then connect speaker cables to the output binding posts on the amplifiers observing correct polarity The output binding posts will accept either bare wire or spades Regulatory agencies in many countries have banned binding posts that will acce...

Страница 10: ...f normal luminance reduced luminance or display off In the display off mode the display will be normally dark yet will provide reduced luminance for several seconds any time a control function on either the remote or integrated amplifier front panel are activated Please note The hand remote is common to several Pass Labs products not all of the functions on this remote are applicable to your integ...

Страница 11: ...ture exceeds 75 degrees Centigrade This thermal cutout should never occur in real life This is a very rare occurrence and would indicate a serious problem We have a general recommendation about interconnects and speaker cables They should cost less than the amplifier and contain at least some conductive material We have tried a lot of products and most work well but as a practical matter we cannot...

Страница 12: ...les but we can say that we have had amplifiers operating in the field in excess of 20 years with no particular mortality and we don t have good information beyond that More to the point you should not worry about it This is a conservatively built industrial design not a frail tube circuit run on the brink of catastrophic failure If it breaks we will simply get it fixed so sleep well INT 150 Specif...

Страница 13: ... Foreign distributors are only required to offer warranty service on Pass Laboratories product that they have imported Please note Conditions of warranty service and customer rights for product purchased outside the United States may vary depending upon the distribu tor and local laws Please check with your local distributor for specific rights and details Any modifications to Pass Laboratories pr...

Отзывы: