COMMAND TYPE
CONNECTION REQUEST 00H
UPDATE GAINS-PHASE-MUTE 01H
UPDATE ROUTING 08H
CLOSE SINGLE DEVICE 0FH
UPG_MASTERGAIN_CMD 16H
SWITCH_S_CMD 1AH
RECALL_PRESET 1BH
CMD_UPG_BALANCED 1FH
INC_DECR_GAIN_LINKED_CMD 2FH
INC_DECR_GAIN_CMD 30H
INC_DECR_MASTERGAIN_CMD 31H
INC_DECR_MASTERVOLUME_CMD 32H
MUTE_UNMUTE_CMD 33H
UPG_ONLY_GAINS_CMD 34H
CHANGE_PRESET_SWITCH_CMD 3DH
LINK_SWITCH_CMD 3EH
UPG_AUTOMIX_BYP_CMD 61H
UPG_AUTOMIX_MODE_CMD 62H
UPG_AUTOMIX_GS_CMD 64H
READ_AUTOMIX_NOM_ATT_CMD 0EH
UPG_DUCKER_PRIORITY_CMD 66H
UPG_DUCKER_HOLD_CMD 67H
UPG_DUCKER_REL_ATK_CMD 68H
UPG_DUCKER_THR_CMD 69H
VUMETER_OUT_CMD 36H
VUMETER_LIM_CMD 37H
VUMETER_CMP_CMD 38H
READ_VERSION_CMD 39H
CLOSE ALL DEVICES 8FH
READ_MAC_ADDRESS_CMD B2H
VUMETER_IN_CMD 55H
COMMUNICATION BETWEEN DEVICE AND REMOTE CONTROL
READ_VERSION_CMD: CMD=39H
TX:
RX:
The SyncMos version is V1.0 so the user can read Sm0 = 0, Sm1 = 1, Sm2 = 0
The current STM8S version is V1.0.2 so the user can read ST0 = 1, ST1 = 0, ST2 = 2
Type:
type of the device,
Type=1
then the device is DMM8008
STX
ID_M
ID_N
CMD
D0
D1
D2
D3
D4
D5
D6
D7
ETX
F0H
46H
XX
39H
00H
00H
00H
00H
00H
00H
00H
00H
F7H
F0H
46H
XX
39H
Sm0
Sm1
Sm2
St0
St1
St2
46H
Type
F7H
STX
ID_M
ID_N
CMD
D0
D1
D2
D3
D4
D5
D6
D7
ETX
40