MAINTENANCE

Paslode

®

 tools are built for ease of maintenance.  A few 

simple details will assure trouble-free operation and long 
tool life. Anyone who uses or maintains the tool must read 
the safety and maintenance instructions.  Study the sche-
matic drawing before starting any repairs on the tool.

Air-operated tools must be inspected periodically, and worn 
or broken parts must be replaced to keep the tool operating 
safely and ef

fi

ciently.  Also the items on the maintenance 

chart must be checked often.

Cold Weather Care

When temperatures are below freezing, tools should be 
kept warm by any convenient, safe method.  If this is not 
possible, the following procedure should be used to warm 
up the tools.

Reduce the regulated air pressure to 30 psi.

Remove all fasteners from the tool.

Collect an air line and blank 

fi

re the tool. The reduced

air pressure will be enough to free-

fi

re the tool. Slow speed

operation tends to warm up the moving parts. Slowing up
the piston helps the bumper and the O-rings to become
springy.

Once the tool is warmed up, readjust the regulator to

the proper working pressure and reload the tool.

Open the drain on the air compressor tank to drain any

moisture at least daily in extremely cold or humid weather.
A few ounces of anti-freeze in the tank will keep the air
free of frost.

Testing the Tool After Servicing

After replacing any part or parts, it is important to check 
the tool for proper operation.  This ensures that the tool 
was put together correctly, is safe to use, and will perform 
the job properly.

Ensure that all hardware is tight.

Ensure that the work contacting element is installed

correctly in relation to the trigger, and that both parts move
freely.

Ensure that the magazine is properly attached.

Ensure that the required safety information on the tool

is legible.

Use only Paslode approved fasteners in the tool, and

ensure that they are correct for the application.

Ensure that a male air 

fi

tting is securely connected to

the tool.

Test the tool by driving fasteners into a workpiece iden-

tical to the tool's application.

Check the tool for air leaks during testing and for the

proper sequence of operation.

Ensure that all fasteners are driven to the same depth

and that the crown of the fastener is 

fl

ush with the work-

piece.

  

Most minor problems can be resolved quickly and easily
using the maintenance table that follows. If problems per-
sist, contact your Paslode dealer for assistance.

Содержание T250S-F16P

Страница 1: ...customer s responsibility to have all operators and service personnel read and understand this manual OPERATING MANUAL AND TOOL SCHEMATIC P Part No 515500 MODELT250S F16P 16 Gauge Straight Finish Nai...

Страница 2: ...y which proves to be defective within the specific time period Any replacement part or accessory provided in accordance with this warranty will carry a warranty for the balance of the period of warran...

Страница 3: ...T male plug The inside diameter should be 28 7mm or larger The fitting must be capable of discharging tool air pressure when disconnected from the air supply OPERATING AIR PRESSURE 80 to 120 p s i 5...

Страница 4: ...work contacting element is working properly The tool could DISCONNECT THE TOOL WHEN NOT IN USE moving the tool to a new location The tool must never be left unattended because people who are not famil...

Страница 5: ...y reload another strip of nails Depth of Drive Adjustment Disconnect the air supply The depth of drive adjustment is done by turning the adjustment wheel located below the trigger Clearing a Jam An oc...

Страница 6: ...r to avoid unintentional fastener discharge 6 Reversible Belt Hook The belt hook can be changed from the left hand side of the tool to the right hand side To change the position squeeze the base of th...

Страница 7: ...ool Open the drain on the air compressor tank to drain any moisture at least daily in extremely cold or humid weather A few ounces of anti freeze in the tank will keep the air free of frost Testing th...

Страница 8: ...revent accumulation of moisture and dirt Prevent clogging of filter with dirt Prevent air leakage and pro mote efficient operation Promote operator safety and efficient tool operation Prevent jamming...

Страница 9: ...minimum Adjust the depth of drive adjustment extend length Reduce air pressure Open front guide latch release jammed fastener and close latch securely Check magazine for proper fasteners Magazine foll...

Страница 10: ...P Safety Glasses 382 1 0 4 o N t r a P r a e l C ACCESSORIES An Illinois Tool Works Company 120 Travail Rd Markham Ontario L3S 3J1 2018 Illinois Tool Works Inc 10...

Страница 11: ...nt de s assurer que tous les utilisateurs et le personnel d entretien et de r paration lisent et comprennent ce guide Mod le T250S F16P Num ro de pi ce 515500 Cloueuse de Finition Pour Clous Droits de...

Страница 12: ...rant la pi ce originale qui est remplac e Cette garantie ne s applique pas aux pi ces de remplacement requises par une usure normale Cette garantie est nulle dans le cas d un outil qui a t as sujetti...

Страница 13: ...OUTIL PRESSION D AIR DE FONCTIONNEMENT 5 5 8 3 bars 80 120 p s i Choisissez une pression d air de fonctionnement comprise dans cette plage pour obtenir le meilleur rendement de l outil NE D PASSEZ PA...

Страница 14: ...saccoupler l outil de la source d air lorsqu il est remis lorsque vous quittez le chantier de travail ou que vous transportez l outil vers un autre endroit L outil ne doit jamais tre laiss sans survei...

Страница 15: ...outil se verrouille automatiquement pour pr venir tout fonctionnement de l outil Pour d bloquer l outil recharger simplement une autre bande d attaches D brancher l alimentation en air Le r glage de l...

Страница 16: ...us voulez enfoncer une attache Maintenez la g chette enfonc e et continuez faire des rebonds de l l ment de pointe de contact contre la pi ce travailler tout en positionnant aussi soigneusement que po...

Страница 17: ...les consignes de s curit et d entretien Examinez les sch mas avant d entamer toute r paration sur cet outil Les outils pneumatiques doivent tre inspect s r guli rement et Si les temp ratures tombent...

Страница 18: ...r un fonctionnement plus efficace V rifiez le bon serrage des vis quotidiennement Assurez vous que l l ment de pointe de contact fonctionne correctement Pour favoriser la s curit de l utilisateur et u...

Страница 19: ...utilisation de temps en temps aucune attache n est ject e V rifier que le magasin contient des attaches appropri es Le pourvoyeur du magasin doit glisser librement Si n cessaire retirer les d bris pr...

Страница 20: ...Transparentes Pi ce n 401382 ACCESSOIRES Lunettes de s curit 120 Travail Rd Markham Ontario L3S 3J1 Une compagnie d Illinois Tool Works 10 MD...

Отзывы: