User Interface, functionality and maintenance 

The  instrument  automatically  switches  from  µS  to  mS  and  vice  versa,  based  on  the 
conductivity it measures. 

The temperature value is shown in ° C (Default) and ° F. Once the unit of measurement 
has been changed, the instrument keeps track of the choice made and will keep it until 
further modification, even after switching the device off and on again. When you reset 
the instrument, the unit of measurement returns to the Default one, ie ° C. 

Functionality 

The  interface  consists  of  a  single  button  for  all  functions.  The  instrument  detects  the 
number of presses or the time of pressing to perform specific functions: 

 

ON; 

 

OFF; 

 

Back-lighting; 

 

Change the unit of measure of the temperature; 

 

Display of the remaining battery charge - percentage; 

 

Sensitivity selection for level detection; 

 

Reset to factory settings; 

 

Calibration. 

 

ON 

When the instrument is switched off, short press the “ON/OFF” button.  

 

OFF 

Press and hold the “ON/OFF” button, until the sound signal and light are activated. 

 

Back-lighting 

 

The backlight  is  activated  with  a single  short  press  of  the "SETTING"  button.  It  will 
remain active for about a minute and a half. 

 

Содержание WMS-LTC

Страница 1: ...WMS LTC User Manual Temperature Level Conductivity meter P A S I srl via Galliari 5 E 10125 TORINO Italy Tel 39 011 650 70 33 Fax 39 011 658 646 E mail sales pasisrl it www pasisrl it...

Страница 2: ......

Страница 3: ...ivity 6 Level Indicator 6 Power supply 6 Display 7 User Interface 7 5 User Interface functionality and maintenance 8 Panel 8 Functionality 9 ON 9 OFF 9 Back lighting 9 Changing the unit of measure of...

Страница 4: ...by P A S I srl All rights reserved P A S I software and programs are delivered as is P A S I products have not been designed to be used in any way or application other than those mentioned This guide...

Страница 5: ...ions described in this manual Faultless and safe operation of the device can be guaranteed only if the transport storage handling and operation of the device is appropriate To avoid damage use only or...

Страница 6: ...which the temperature and conductivity indications are shown The water level will be visible on the cable marked in centimetres The instrument is also equipped with a sound signal and LED that indica...

Страница 7: ...cable four copper wires kevlar core and external antiscratch protective film in transparent PUR Graduation in centimeters printed in black on the cable itself with meter decimeter indication Probe Pr...

Страница 8: ...cm normalized at 25 C Range from 40 S cm to 80000 S cm Precision 5 of the reading Level Indicator Sensitivity 4 sensitivity levels automatic or manual selection Signaling Sound signal and red LED indi...

Страница 9: ...1 Conductivity Line 2 Temperature User Interface Push button Single button for on off and settings NOTICE When the batteries are flat the instrument will automatically switch off and display a low ba...

Страница 10: ...ut the instrument and its functions The 2 lines on the display show respectively Conductivity level normalized to 25 C Temperature Conductivity is displayed in S cm when next to the reported value onl...

Страница 11: ...ne ie C Functionality The interface consists of a single button for all functions The instrument detects the number of presses or the time of pressing to perform specific functions ON OFF Back lightin...

Страница 12: ...When there is high conductivities however manual selection of sensitivity may be more effective The instrument has 4 thresholds Ultra low used for pure water Low Medium High for high conductivity You...

Страница 13: ...that the probe is clean We suggest using denatured ethyl alcohol see Maintenance paragraph Before and between each measurements it is important that the probe is thoroughly rinsed in distilled water t...

Страница 14: ...12 To clean the probe it is recommended to use denatured ethyl alcohol and then rinse it in distilled water This procedure is very important to get an accurate reading...

Страница 15: ...5 minutes For an accurate reading of the level conductivity and temperature it is recommended to proceed as follows Unwind the cable until the level is reached Wind the cable slowly by pulling the pro...

Отзывы: