background image

®

PS-3517

Technical Support

5

012-15719A

Copyright

This PASCO scientific instruction sheet is copyrighted with all rights 

reserved. Permission is granted to non-profit educational institutions for 

reproduction of any part of this manual, providing the reproductions are 

used only in their laboratories and classrooms, and are not sold for profit. 

Reproduction under any other circumstances, without the written consent 

of PASCO scientific, is prohibited. Rev: 10/17

Trademarks

PASCO, PASCO scientific, PASCO Capstone, PASPORT and 

SPARKvue are trademarks or registered trademarks of PASCO scientific, 

in the United States and/or in other countries. All other brands, products, 

or service names are or may be trademarks or service marks of, and are 

used to identify, products or services of, their respective owners. For more 

information visit www.pasco.com/legal.

Product End of Life Disposal Instructions:

This electronic product is subject to disposal and recycling regulations that 

vary by country and region. It is your responsibility to recycle your 

electronic equipment per your local environmental laws and regulations to 

ensure that it will be recycled in a manner that protects human health and 

the environment. To find out where you can drop off your waste equipment 

for recycling, please contact your local waste recycle/disposal service, or 

the place where you purchased the product.
The European Union WEEE (Waste Electronic and 

Electrical Equipment) symbol (to the right) and on the 

product or its packaging indicates that this product 

must not be disposed of in a standard waste 

container.

Содержание PS-3517

Страница 1: ...d area Boot 1 Cover DO NOT let the BNC connector at the top of the unit get wet Included Equipment Item Included Equipment Item Carbon Dioxide ISE Electrode Body 2 1 CO2 Standard Solution 1000 ppm 4 Carbon Dioxide ISE Internal Electrode 2 CO2 Reference Fill Solution 5 BNC Male to Female Cable 3 CO2 Ionic Strength Adjuster ISA 6 ...

Страница 2: ...e tip of the internal glass electrode Keep the boot for later use Note Soaking the internal glass electrode in internal filling solution or pH 4 01 buffer for at least 1 hour before proceeding with the following steps will ensure fast response 2 Remove an electrode body from the box Using the solution provided fill the electrode body with about 3 5 mL of Reference Fill Solution 3 Rinse the interna...

Страница 3: ...ctrode response follow the steps below 1 Check the slope of the internal glass electrode Remove the internal glass electrode from the electrode body Connect the internal glass electrode to the Wireless pH Sensor or to a pH mV meter Put the internal glass electrode in pH 7 00 buffer The annular ceramic junction should be immersed in the solution Record the reading in mV when it is stable Remove the...

Страница 4: ...100 mL of the sample into a 150 mL beaker Add 1 mL of ISA Stir thoroughly Check the pH value of the standard 6 Rinse electrode with Dl water blot dry and place in the sample beaker Wait for a stable reading and the sample concentration will be displayed on the mea suring device 7 Determine the sample concentration using the data analysis tools in the software Electrode Storage Short Term over nigh...

Страница 5: ...ay be trademarks or service marks of and are used to identify products or services of their respective owners For more information visit www pasco com legal Product End of Life Disposal Instructions This electronic product is subject to disposal and recycling regulations that vary by country and region It is your responsibility to recycle your electronic equipment per your local environmental laws...

Отзывы: