background image

®

PS-2108

The PS-2108 Dissolved Oxygen Sensor measures the amount of 
dissolved oxygen in a solution in milligrams per liter.

Dissolved Oxygen Quick Start

Additional Equipment Needed

PASPORT Link Device (USB Link, 

Xplorer

, etc.)

EZscreen or DataStudio

TM

 software (version 1.6 or later)

Equipment Setup

1. Connect the PASPORT Link Device to a USB port on your computer or USB hub.
2. Connect the Dissolved Oxygen probe to the sensor.
3. Connect the sensor to the PASPORT Link Device.
4. The software launches when it detects a PASPORT sensor. From the 

PASPORTAL screen, select a point of entry:

  an activity in the Workbook window,

  EZscreen, or 

  DataStudio.

Sensor Specifications

Sensor Range:

0

20 mg/L

Accuracy:

±10% of full scale

Resolution:

0.01 mg/L

Max Sample Rate:

20 sps

Default Sample Rate:

2 sps

Response:

98% in 60 seconds

Temperature Range:

0

50

°

C

Temperature Compensation:

10

40

°

C

Cathode:

Platinum

Anode:

Ag/AgCl

Membrane:

1 ml silicon

800-772-8700  •  916-786-3800  •  [email protected]  •  www.pasco.com

012-07688B

1

2

3

Dissolved Oxygen 
Sensor

Note:

 Prior to first use, fill the 

electrode membrane cartridge and 
housing with a filling solution. Refer 

to

 

the Maintenance card included 

with the sensor.

®

PS-2108

The PS-2108 Dissolved Oxygen Sensor measures the amount of 
dissolved oxygen in a solution in milligrams per liter.

Dissolved Oxygen Quick Start

Additional Equipment Needed

PASPORT Link Device (USB Link, 

Xplorer

, etc.)

EZscreen or DataStudio

TM

 software (version 1.6 or later)

Equipment Setup

1. Connect the PASPORT Link Device to a USB port on your computer or USB hub.
2. Connect the Dissolved Oxygen probe to the sensor.
3. Connect the sensor to the PASPORT Link Device.
4. The software launches when it detects a PASPORT sensor. From the 

PASPORTAL screen, select a point of entry:

  an activity in the Workbook window,

  EZscreen, or 

  DataStudio.

Sensor Specifications

Sensor Range:

0

20 mg/L

Accuracy:

±10% of full scale

Resolution:

0.01 mg/L

Max Sample Rate:

20 sps

Default Sample Rate:

2 sps

Response:

98% in 60 seconds

Temperature Range:

0

50

°

C

Temperature Compensation:

10

40

°

C

Cathode:

Platinum

Anode:

Ag/AgCl

Membrane:

1 ml silicon

800-772-8700  •  916-786-3800  •  [email protected]  •  www.pasco.com

012-07688B

1

2

3

Dissolved Oxygen 
Sensor

Note:

 Prior to first use, fill the 

electrode membrane cartridge and 
housing with a filling solution. Refer 

to

 

the Maintenance card included 

with the sensor.

Отзывы: