background image

Aluminium and aluminium alloy parts use less than 4% by weight of each homogeneous component. 

Only dispose off in authorised sites for electrical and electronic waste do not dispose of with general refuse or landfill waste.

www.parweld.com

17

9.2 WEEE Statement

WEEE (Waste Electrical & Electronic Equipment) 2002/96/EC
 
In relation to implementing the legislation, Parweld has established relevant recycling and recovery methods.  We have been fully compliant 

against the marking requirements since August 2005. Parweld is registered in the UK with the Environment agency as detailed below.  For 

WEE compliance outside the UK please contact your supplier/Importer

Parweld is registered with a compliance scheme Official registration number is WEE/FD0255QV

When your equipment reaches the end of its service life you should return it to Parweld where it will be reconditioned or processed for 

recycling.

9.3 Statement of warranty

Limited Warranty: 
Parweld Ltd, hereafter, “Parweld” warrants its customers that its products will be free of defects in workmanship or material. Should any failure 

to conform to this warranty appear within the time period applicable to the Parweld products as stated below, Parweld shall, upon notification 

thereof and substantiation that the product has been stored, installed, operated, and maintained in accordance with Parweld’s specifications, 

instructions, recommendations and recognized standard industry practice, and not subject to misuse, repair, neglect, alteration, or accident, 

correct such defects by suitable repair or replacement, at Parweld’s sole option, of any components or parts of the product determined by 

Parweld to be defective.

Parweld makes no other warranty, express or implied. This warranty is exclusive and in lieu of all others, including, but not limited to any 

warranty of merchantability or fitness for any particular purpose.

Limitation of Liability: 

Parweld shall not under any circumstances be liable for special, indirect or consequential damages, such as, but not limited to, lost profits and 

business interruption. The remedies of the purchaser set forth herein are exclusive and the liability of Parweld with respect to any contract, or 

anything done in connection therewith such as the performance or breach thereof, or from the manufacture, sale, delivery, resale, or use of any 

goods covered by or furnished by Parweld whether arising out of contract, negligence, strict tort, or under any warranty, or otherwise, shall not, 

except as expressly provided herein, exceed the price of the goods upon which such liability is based. No employee, agent, or representative 

of Parweld is authorized to change this warranty in any way or grant any other warranty.

Purchaser’s rights under this warranty are void if replacement parts or accessories are used which in Parweld’s sole judgement may impair the 

safety or performance of any Parweld product.

Purchaser’s rights under this warranty are void if the product is sold to purchaser by non-authorized persons.

The warranty is effective for the time stated below beginning on the date that the authorized Distributor delivers the products to the purchaser. 

Notwithstanding the foregoing, in no event shall the warranty period extend more than the time stated plus one month from the date Parweld 

delivered the product to the authorized distributor.

Main Transformers and Rectifiers 2 Years

Other machine parts 2 year

Содержание XTM303C

Страница 1: ...Operator Manual ISSUE 3 XTM303C...

Страница 2: ...er maintanance this equipment should provide years of reliable service All our systems conform to ISO9001 2000 and are independently audited by NQA The entire product range carries the CE mark and is...

Страница 3: ...ing drive roll sets 7 5 6 Welding wire installation 7 5 7 Torch installation 8 5 8 Work return lead connection 9 5 9 Shielding gas connection 9 6 0 Operation 9 6 1 Feeding wire electrode 9 6 2 Optimis...

Страница 4: ...manual Wear a safety harness if working above floor level Keep all panels and covers securely in place Clamp work cable with good metal to metal contact to work piece or worktable as near the weld as...

Страница 5: ...or before going near arc welding gouging or spot welding operations NOISE can damage hearing Noise from some processes or equipment can damage hearing Wear approved ear protection if noise level is hi...

Страница 6: ...does not go off when the power source has cooled down then have the machine checked by a qualified engineer 6 On Off switch The machine is switched off when the light 4 is off and the fan is not runn...

Страница 7: ...is suitably rated for the power draw of the machine and the environmental location Have a qualified electrician connect the input plug For long runs over 30m larger copper wires should be used The gre...

Страница 8: ...ource inch facility or torch trigger to feed the electrode wire 50mm from the end of the liner conduit 5 Once the electrode wire has stopped refit the tip adaptor diffuser contact tip and gas nozzle 6...

Страница 9: ...e head and body protection 1 Position wire over joint The end of the wire may be lightly touching the work 2 Lower welding helmet operate gun trigger and begin welding Hold the gun so the contact tip...

Страница 10: ...feed speed Improper welding technique Place stringer bead in proper locations at joint during welding Adjust work angle or widen groove to access bottom during welding Momentarily hold arc on groove...

Страница 11: ...perates but does not feed Insufficient drive roll pressure Incorrect drive rolls Excessive wire spool brake tension Incorrect liner Blocked liner Bird nesting Burn back Bird nesting Excessive feed rol...

Страница 12: ...ch spares 12 XP8 300A Air Cooled Mig Welding Torch Rating 300A 8 7kW Mixed Gas 80 20 80 Duty Cycle EN60974 7 0309 0459 0 0 8mm to 1 2mm wires B A 2 1 4 3 6 5 7 8 9 10 11 12 13 14 15 17 16 18 19 21 21...

Страница 13: ...9 0459 1 0mm 1 2mm x 10ft 3m XP2024 12 40 Steel Liner 0409 0459 1 0mm 1 2mm x 13ft 4mt XP2024 12 50 Steel Liner 0409 0459 1 0mm 1 2mm x 16ft 5m NI XP2024PC 12 30Polyamide Copper Liner 0309 0459 0 8mm...

Страница 14: ...0 Bar E700113 1 Gauge Argon 30 lpm flow E700123 2 Gauge Argon 30 lpm flow Flow Meters Features Designed from brass bar whilst the tube and cover are moulded from high quality polycarbonate to ensure...

Страница 15: ...www parweld com 15...

Страница 16: ...M303C The above listed products are certified to be compliant with the rohs directive with all homogeneous component parts being controlled to ensure material contents as per the list below Cadmium 0...

Страница 17: ...ts or parts of the product determined by Parweld to be defective Parweld makes no other warranty express or implied This warranty is exclusive and in lieu of all others including but not limited to an...

Страница 18: ...Parweld Limited Bewdley Business Park Long Bank Bewdley Worcestershire England DY12 2TZ tel 44 1299 266800 fax 44 1299 266900 www parweld com info parweld co uk...

Отзывы: