background image

www.parweld.com

www.parweld.com

Description Possible cause

Remedy

Fault lamp 

is on, no 

power 

output

(a) Machine 

overheated
(b) Over current 

state
(c) Internal fault 

with machine

(a) Allow to 

cool with fan 

running
(b) Switch off 

mains power 

to the machine 

and re start
(c) Have a 

qualified service 

engineer 

inspect
then repair the 

welder

 

ROUTINE MAINTENANCE

The only routine maintenance required for the power 

supply is a thorough cleaning and inspection, with the 

frequency depending on the usage and the operating 

environment.

Warning 

Disconnect primary power at the source before 

removing the cover. Wait at least two minutes before 

opening the cover to allow the primary capacitors to 

discharge.

To clean the unit, remove the screws securing the 

outer cover, lift off the outer cover and use a vacuum 

cleaner to remove any accumulated dirt and dust. The 

unit should also be wiped clean, if necessary; with 

solvents that are recommended for cleaning electrical 

apparatus.

Faul

FI

n

DI

n

G

13

Содержание XTI 160

Страница 1: ...INSTRUCTION MANUAL...

Страница 2: ...Operator Manual ISSUE 6 XTI 160 XTI 161 DV...

Страница 3: ...maintenance this equip ment should provide years of reliable service All our systems conform to ISO9001 2000 and are inde pendently audited by NQA The entire product range carries the CE mark and is c...

Страница 4: ...Installation 6 5 1 Unpacking the Machine 6 5 2 Location 7 5 3 Input and grounding connection 7 5 4 Output Polarity Connections 7 5 5 Torch Installation 7 5 6 Work return lead connection 7 6 0 Operati...

Страница 5: ...unit according to manual Wear a safety harness if working above floor level Keep all panels and covers securely in place Clamp work cable with good metal to metal contact to work piece or worktable as...

Страница 6: ...As welds cool they can throw off slag Wear approved safety glasses with side shields even under your welding helmet BUILDUP OF GAS can injure or kill Shut off shielding gas supply when not in use Alw...

Страница 7: ...he power out put of the machine in LIFT TIG or MMA mode 6 Output power connection Negative this is the 50mm Dinse connection socket for the connection of the negative welding lead 7 Output power conne...

Страница 8: ...n yellow wire in the input cable connects to the frame of the machine This ensures proper grounding of the machine when the machine plug is inserted into the receptacle 5 4 Output Polarity Connections...

Страница 9: ...nge narrower more concentrated arc GREY welding to distribute the heat Cast iron Most types of cast iron except white iron are weldable White iron because of its extreme brittleness generally cracks w...

Страница 10: ...amp b Welding current is too high c Surface impurities such as oil grease paint etc a Dry electrodes before use b Reduce welding current c Clean joint before welding Description Possible cause Remedy...

Страница 11: ...s run b Joint preparation too restricted c Irregular deposits allow slag to be trapped d Lack of penetration with slag trapped beneath weld bead e Rust or mill scale is preventing full fusion f Wrong...

Страница 12: ...b Gas contami nated with air a Clean the electrode by grinding off the contaminates b Check gas lines for cuts and loose fitting or change gas cylinder Description Possible Cause Remedy Electrode melt...

Страница 13: ...e right shielding gas Refer to basic TIG welding guide e Improve connection to work piece Power source problems Description Possible cause Remedy The welding arc cannot be established a The primary su...

Страница 14: ...wer supply is a thorough cleaning and inspection with the frequency depending on the usage and the operating environment Warning Disconnect primary power at the source before removing the cover Wait a...

Страница 15: ...has been stored installed operated and maintained in accordance with Parweld s specifications instructions recommendations and recognized standard industry practice and not subject to misuse repair n...

Отзывы: