background image

PRV-1059

 

User Manual

 

 

Disclaimer 

Although the information contained herein has been carefully verified, Parvus Corporation assumes no responsibility for 
errors that might appear in this document, or for damage to property or persons resulting from improper use of this manual or 
related software. Parvus reserves the right to change the contents and form of this document, as well as the features and 
specifications of its products at any time without notice. The information in this publication does not represent a commitment 
on the part of Parvus. This document contains proprietary information that is protected by copyright. All rights are reserved. 
No part of this document may be photocopied, reproduced, or translated into another language without the prior written 
consent of Parvus. 
 
Parvus Corporation 
3222 S. Washington St. 
Salt Lake City, Utah, USA 84115 
Phone:  +1 (801) 483-1533 
Toll-Free: 

+1 (800) 483-3152 

Main: 

 

+1 (801) 483-1533 

Fax: 

 

+1 (801) 483-1523 

Email: 
 Sales: 

 

[email protected]

 

 Support: 

[email protected]

 

Web-site: 

http://www.parvus.com

 

  
Send us your comments and feedback: 

[email protected]

 

 
Parvus is a U.S. subsidiary of the Eurotech Group (

www.eurotech.com

), a global family of technology companies focused on 

innovative embedded and high performance computing solutions. 

Trademarks

 

All trademarks both marked and not marked, appearing in this document, are the property of their respective owners. 

WEEE 

The information below is issued in compliance with the regulations as set out by the 2002/96/CE directive, subsequently 
superseded by 2003/108/CE, and refers electrical and electronic equipment and the management of their waste (WEEE). 
When disposing of a device, including all of its components, subassemblies and materials that are an integral part of the 
product, you should take the WEEE directive into consideration. 
 

This symbol has been attached to the equipment or, in the case that this is not possible, on the packaging, 
instruction literature and/or the guarantee sheet. By using this symbol it states that the device has been 
marketed after August 13th 2005, and implies that you must separate all of its components when possible, and 
dispose of them in accordance with local waste disposal legislations. 

 

Because of the substances present in the equipment, an improper use or disposal of the refuse can cause damage to 
human health and to the environment.   

 

With reference to WEEE, it is compulsory not to dispose of the equipment with normal urban refuse; arrangements should be 
instigated for separate collection and disposal.  

 

For more detailed information about recycling of WEEE, please contact your local waste collection body. 

 

In case of illicit disposal, sanctions will be levied on transgressors. 

RoHS 

This device, including all it components, subassemblies and the consumable materials that are an integral part of the 
product, has been manufactured in compliance with the European directive 2002/95/EC known as the RoHS directive 
(Restrictions on the use of certain Hazardous Substances), this directive targets the reduction of certain hazardous 
substances previously used in electrical and electronic equipment (EEE). 

 

Page 2 of 27

 

MNL-0490-01 RevD4 

REF. ECO-3163 

Effective: 01 Feb 10 

Содержание PRV-1059

Страница 1: ...USER MANUAL PRV 1059 5 Port PC 104 10 100 Fast Ethernet Switch MNL 0490 01 Rev D4 REF ECO 3163 01 Feb 10 RUGGED SOLUTIONS FOR REAL WORLD APPLICATIONS www parvus com...

Страница 2: ...CE directive subsequently superseded by 2003 108 CE and refers electrical and electronic equipment and the management of their waste WEEE When disposing of a device including all of its components su...

Страница 3: ...n Description Ports 0 4 10 CON2 J101 2 Pin Power Connector 10 Parallel LED Ports 10 J1 J3 PC 104 Bus 11 Chapter 4 Operational Description 12 Switch Data Flow 12 Media Access Controllers 12 Backoff 12...

Страница 4: ...ions 21 Temperature 21 Reliability MTBF 21 Mechanical 21 Weight 21 Dimensions 22 Chapter 6 Troubleshooting 24 Technical Assistance 24 Returning For Service 24 Chapter 7 Contact Info 25 Eurotech Group...

Страница 5: ...processor board required or in combination with embedded systems that support a PC 104 ISA bus The card integrates fully independent media access controllers MACs an embedded frame buffer memory and a...

Страница 6: ...Highly integrated DSP based 10 100 switch Look up engine supports as many as 1 024 MAC address entries 2 Pin Power Header for External Power Connections select models only 16 bit PC 104 Bus select mod...

Страница 7: ...vice that cannot automatically correct for crossover the switch makes the necessary adjustment prior to commencing auto negotiation Similarly if the switch interoperates with a device that implements...

Страница 8: ...cription of the connectors located on the 10 100 Ethernet Switch Molex Connectors Connector Part Numbers Ethernet 4 pin right angle P N 22 12 2044 mating P N 10 11 2043 Power 2 pin right angle P N 22...

Страница 9: ...PRV 1059 User Manual 10 100 Ethernet Switch w 4 pin Molex Ethernet Connectors MNL 0490 01 RevD4 REF ECO 3163 Effective 01 Feb 10 Page 9 of 27...

Страница 10: ...or Not Loaded on PC 104 Versions Molex Connector P N 22 12 2024 mating P N 10 11 2023 Pin Signal Pin 1 5VDC closest to mounting hole Pin 2 GND Parallel LED Ports For All LED Ports JP11 through JP15 Mo...

Страница 11: ...5v 17 SA14 DA1 SD14 MSTR 18 SA13 DRQ1 SD15 GND 19 SA12 Rfrsh key GND 20 SA11 SCLK 21 SA10 IRQ7 22 SA9 IRQ6 23 SA8 IRQ5 24 SA7 IRQ4 25 SA6 IRQ3 26 SA5 DA2 27 SA4 TC 28 SA3 BALE 29 SA2 5v 30 SA1 OSC 31...

Страница 12: ...nsmitter waits by deferring its transmission When the line is available the transmission insures a minimum interpacket gap of at least 96 bits has occurred and then transmits a 56 bit preamble and an...

Страница 13: ...function see section 3 4 4 Address Translation Unit The Lookup Engine or Address Translation Unit ATU reads the Destination Address DA and Source Address SA from each received packet performing all ad...

Страница 14: ...the switch negotiates with a link partner to determine the speed and duplex with which to operate It the partner is unable to negotiate the switch goes to a detection mode to determine the speed and t...

Страница 15: ...2 may talk to port 0 but NOT to port 1 In contrast port 0 may talk to either port 1 or 2 and port 1 may talk to port 0 or 2 Furthermore ports 3 and 4 are configured to form a different VLAN and can t...

Страница 16: ...ribe the process required to setup the VLAN software from an administrator s user s standpoint I Connect the serial port of the PRV 1059 J5 to the COM port of the CPU using the Parvus VLAN serial cabl...

Страница 17: ...indow Com Port In order to program the PRV 1059 the computer running the software must be connected to the serial port of the switch The default COM port for the host computer is set to COM 1 If the u...

Страница 18: ...ress port but on the PRV 1059 it is possible for each to have between zero and four egress ports There are 5 egress port configuration schemes ranging from Set Egress Ports for Port 0 to Set Egress Po...

Страница 19: ...AN operation button area for Apply Reset Query Update Clear all SET GET and Exit d Parvus logo area The operation button area is the most important area because all VLAN configurations setting display...

Страница 20: ...the top right of the GUI window and then pressing this button will set the switch s registers g GET This button is used for internal troubleshooting or testing by Parvus Pressing this button will show...

Страница 21: ...has either been designed to meet or tested to Temperature Operating 40 C to 85 C Non Operating 55 C to 100 C Reliability MTBF The following table shows the predicted values for reliability of the PRV...

Страница 22: ...ning PC 104 specifications state that max height may only be 0 435 Be sure that the board height of 0 52 for the RJ 45 version will operate in your application This applies to the RJ 45 version only P...

Страница 23: ...n Molex Version Note The external power connector J101 on models without the PC 104 bus is a right angle two pin Molex connector that extends from the board 32 Note For further information about the m...

Страница 24: ...rned Material Authorization RMA request form available for download from the following website under the support section www parvus com Email this form to the email address listed above to receive aut...

Страница 25: ...3 1533 Fax 1 801 483 1523 Sales 1 800 483 3152 or 801 483 1533 sales parvus com Product Technical Support 1 801 433 6322 tsupport parvus com Customer Feedback feedback parvus com Company contact info...

Страница 26: ...358 9 477 888 0 Fax 358 9 477 888 99 E mail sales fi eurotech com E mail support fi eurotech com Web www eurotech com ASIA Japan ADVANET Tel 81 86 245 2861 Fax 81 86 245 2860 E mail sales advanet co j...

Страница 27: ...www parvus com...

Отзывы: