![Partner RP-100-300II Скачать руководство пользователя страница 56](http://html.mh-extra.com/html/partner/rp-100-300ii/rp-100-300ii_programing-manual_760670056.webp)
-------------Thermal Printer-------------
Other information
Hex
Decimal
Condition
30H
48
Printing is possible
31H
49
Printing is impossible
Size information indicates size of symbol that is printed by Function 181.
The quiet zone is not included in the size information.
If “other information” is “Printing is impossible “(in decimal: 49)
,
use one of the solutions
shown below.
Cause
Solution
There are data in the print buffer
in the standard mode
Put the printer in the
“
there is no data in the
print buffer” status by executing GS T or print
commands (LF, CR, ESC J).
Symbol is bigger than the current
print area.
Expand the print area by GS W, ESC W, ESC $.
Reduce the module size by Function 167.
Lower the error correction level by Function 169.
The data in the symbol storage
area is too large.
Send correct data by Function 180.
Select other model by Function 165
Lower the error correction level by Function 169.
There is no data in the symbol
storage area.
Send data to the symbol storage area by Function
180.
■
See previous [Notes for transmission process] for process sending data group.