![Parsun F15/F9.9BM Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/parsun/f15-f9-9bm/f15-f9-9bm_service-manual_3802328043.webp)
PULSED COIL INSPECTION
1. Pulsed coil peak voltage
Use the digital circuit tester and peak voltage adaptor to measure the peak voltage. If below the
specification, check the pulsed coil resistance.
Digital circuit tester Peak voltage adaptor
Start (no-load)
4.0
Start (load)
4.0
1500r/min (load)
9
Pulsed coil peak voltage
3500r/min (load)
17V
2. Pulsed coil resistance
Measure the pulsed coil resistance. Replace if out of specification, replace.
Resistance:
234~348Ω (
Tester (+) pole: red/white wire; Tester (-) pole: black wire)
CHARGE COIL INSPECTION
1. Charge coil peak voltage
Use the digital circuit tester and peak voltage adaptor to measure the peak voltage. If below the
specification, check the charge coil resistance
.
Digital circuit tester Peak voltage adaptor
Start (no-load)
175V
Start (load)
170V
1500rmp
180V
Charge coil peak voltage
3500rmp
180V
2. Charge coil resistance
Measure charge coil resistance. Replace if out of specification.
Resistance:
272~408Ω (
Tester (+) pole: brown wire; Tester (-) pole: blue wire)
37
Содержание F15/F9.9BM
Страница 1: ...PARSUN OUTBOARD ENGINE SERVICE MANUAL F15 F9 9BM F15 F9 9W SUZHOU PARSUN POWER MACHINE CO LTD...
Страница 13: ...DETECTION DEVICE Digital tachometer Digital circuit tester Peak voltage adaptor 7...
Страница 36: ...EXPLOSIVE DRAWING REMARKS PART NO DESCRIPTION 30...
Страница 37: ...REMARKS DESCRIPTION PART NO 110 Nm O M6x20 mm 8Nm O 18 Nm 31...
Страница 38: ...PART NO DESCRIPTION REMARKS 18 Nm O M6x20 mm 8Nm O 110 Nm 32...
Страница 39: ...Electric start type PART NO DESCRIPTION REMARKS 30 Nm 33...
Страница 40: ...PART NO DESCRIPTION REMARKS 34...