background image

  

 

Parry

-British Built for Purpose 

IN205-4

 

14 

  Exploded View  

 

 
 

19

8

7

30

14

1

18

17

2

3

25

22

9

16

13

23

26

24

29

33

28

27

4

5

10

12

31

32

11

21

20

15

6

 

 

 

 

 
 
 

Содержание PGF600G

Страница 1: ...Instruction Manual LPG Gas Griddles PGF600G PGF800G PGF1000G ...

Страница 2: ......

Страница 3: ...uctions 6 Cleaning Instructions 7 Maintenance Instructions 8 Conversion Instructions 9 Technical Information 10 11 Fault Finding 12 Service Information 13 Exploded View 14 Parts List 15 16 Warranty Information 17 Disposal Recycling 18 Parry Catering Equipment Midlands Ltd Town End Road Draycott Derby DE72 3PT Sales Tel 01332 875544 Fax 01332 874455 ...

Страница 4: ...2 5 29 35 Packed weight kg 25 32 57 Dimensions w x d x h mm 620 x 470 x 200 820 x 470 x 200 1020 x 470 x 200 Warranty 2 years 2 years 2 years KW Natural KW Propane Butane n a 5 5 n a 8 25 n a 9 3 BTU Natural BTU Propane Butane n a 18 766 n a 28 149 n a 31 732 Input Gas Connection BSP Male BSP Male BSP Male GAS INPUT PRESSURE Natural GAS INPUT PRESSURE Propane GAS INPUT PRESSURE Propane Butane 20mb...

Страница 5: ...and the NATIONAL REGULATIONS in force at the time Particular attention should be paid to the Gas Safety Installation and Use Regulations and the Health and Safety at Work Act Each appliance requires a flow of fresh air for combustion Under no circumstances should air vents on the appliances or air vents installed by the fitter in the room of the appliance to supply combustion air be altered or omi...

Страница 6: ...g installation provision must be made for combustion air supply to the appliance which enters the appliance through the base and rear of the appliance this should not be blocked at any time SEE TECHNICAL DETAILS Appliances are designed to be installed on Parry Catering Equipment for stability if they are fitted on any other surface they should be suitably secured to prevent excessive movement Conn...

Страница 7: ...les should be drilled on the work surface for the location of where the feet will sit Screws will be placed through the work surface so the feet of the appliance can sit directly on top of the screws so appliance can not move Sizes required GGP6 4 295mm x 332mm Sizes required GGP6 6 295mm x 532mm Sizes required GGP6 8 295mm x 732mm Sizes required GGP6 10 295mm x 932mm IMPORTANT After installing th...

Страница 8: ...ght within 1 minute abort the lighting process for at least 2 minutes to allow gas to disperse Turn knob anti clockwise to obtain main gas The lowest setting has been set at the factory and sealed This must not be adjusted by user To turn burner off turn knob in a clockwise direction all the way round to We advise that the appliance should not be left unattended when switched on The appliances are...

Страница 9: ...se Wipe down the machine with hot soapy water using a soft cloth do not use abrasive materials Cleaning of the griddle plate it may be necessary to use a griddle stone to remove carbon build up Once this has been done seasoning of the plate will be necessary Stainless steel cleaners maybe used on the exterior and cleaning instructions on the product must be adhered to Never clean the unit with wat...

Страница 10: ...ing spares straight from the manufacturer allows customer to experience exceptional value and speedy delivery on all spare parts For more information on buying spares visit www parry co uk parry commercial catering spares In order to clean or replace the burner loosen the nut that connects the 8mm gas pipe to the aluminium part Loosen the nut that connects the thermocouple to the aluminium part an...

Страница 11: ...loosen the screws that attach the side panels corners This way the whole assembly front panel and corners will come out together The thermocouple and the electrode are attached to the aluminium part which is attached to the burner support In order to take out the aluminium part it s necessary to unscrew the pipe that links the tap to the burner and the 2 screws that hold the burner frontal support...

Страница 12: ...R G25 25mb 0 615 M HR 21 719 FT HR INJECTORS Natural G20 INJECT 115 Butane G30 INJECT 85 Propane G31 INJECT 85 G25 25mb INJECT 115 PGF800G GGP6 8 Total Unit GAS OPERATING PRESSURE TOTAL HEAT INPUT NATURAL G20 20mb 8 W G 8 250 KW 28150 Btu h BUTANE G30 29mb 11 2 W G 8 250 KW 28150 Btu h PROPANE G31 37mb 14 8 W G 8 250 KW 28150 Btu h G25 25mb 10 W G 7 500 KW 25591 Btu h GAS RATE M HR FT HR LB HR KG ...

Страница 13: ...1733 Btu h PROPANE G31 37mb 14 8 W G 9 300 KW 31733 Btu h G25 25mb 10 W G 8 700 KW 29686 Btu h GAS RATE M HR FT HR LB HR KG HR NATURAL G20 0 990 M HR 34 962 FT HR BUTANE G30 0 303 M HR 10 692 FT HR 1 554 LB HR 0 705 KG HR PROPANE G31 0 399 M HR 14 142 FT HR 1 554 LB HR 0 705 KG HR G25 25mb 1 050 M HR 37 080 FT HR INJECTORS Natural G20 INJECT 125 Butane G30 INJECT 93 Propane G31 INJECT 93 G25 25mb ...

Страница 14: ...ly Ensure gas supply is turned ON to appliance Check to see if a spark is being generated when piezo is pressed If piezo is faulty contact your distributor Unit lights but will not stay lit Ensure you press and hold the control knob in for around 10 seconds If the problem still persists please contact distributor ...

Страница 15: ...d person Enhanced 2 Years Warranty Parry Catering Midlands Ltd offer an enhanced warranty of two years including parts and labour on all of the Parry manufactured products To take advantage of this you should register you warranty by logging onto the company website and filling out our simple form www parry co uk the parry warranty If you have any issues with your product and wish to request a war...

Страница 16: ...Parry British Built for Purpose IN205 4 14 Exploded View 1 9 8 7 30 1 4 1 1 8 1 7 2 3 25 22 9 1 6 1 3 23 26 24 29 33 28 27 4 5 1 0 1 2 31 32 1 1 21 20 1 5 6 ...

Страница 17: ...NT PANEL GGP6 10 7 7 0 302 0006 REAR PANEL GGP6 6 7 7 0 303 0006 REAR PANEL GGP6 8 7 7 0 304 0006 REAR PANEL GGP6 10 8 4 0 201 0001 COURNER GL 9 4 0 301 0028 IGNITOR FASTON 2 8x0 5 10 7 0 301 0020 FRONT BURNER SUPPORT SBF 11 4 0 100 0010 TAP HANDLE STICHER 12 7 0 301 0021 REAR BURNER SUPPORT SBF 13 4 0 301 0031 INJECTOR SUPPORT 14 7 0 302 0030 STRUCTURE REINFORCEMENT GL500 6 14 7 0 303 0030 STRUCT...

Страница 18: ...1 0012 PLATE REAR SUPPORT ø15x34 5mm GL500 26 4 0 301 0033 GAS TERMOCOUPLE 250MM FASTON 8X1 27 4 0 301 0045 GAS INJECTOR M6x0 75 1 25 GGP6 4 GGP6 10 27 4 0 301 0044 GAS INJECTOR M6x0 75 1 15 GGP6 6 GGP6 8 28 4 0 301 0043 GAS INJECTOR M6x0 75 0 93 GGP6 4 GGP6 10 28 4 0 301 0042 GAS INJECTOR M6x0 75 0 85 GGP6 6 GGP6 8 29 4 0 301 0035 SBF IGNITION PILOT FIXING SPRING 30 7 0 302 0027 DRAIN TRAY GL500 ...

Страница 19: ...allation date of the equipment To be eligible for a 2 year warranty products must be serviced at least once within the first 12 months of purchase All service calls will be carried out between 8am and 5pm Monday to Friday Your warranty is invalid if your equipment has not been installed in accordance with the manufacturer s instructions The misuse alteration or unauthorised repairs of the equipmen...

Страница 20: ...Parry British Built for Purpose IN205 4 18 Disposal Recycling Packaging should be disposed of according to regulations in place ...