background image

 

Parry

-British Built for Purpose 

IN258-3 

 

12 

  Natural Gas – Conversion Instructions

 

 
 

 

 

Product 

 
GB6 – 6 Burner Oven LPG 

 

For use with models with the following serial numbers 
 

Model 

From 

To 

GB6P 

 

 

 
These instructions can be used for converting from LPG to Natural Gas 
 

LPG units are designed and tested in accordance with all current regulations enforced to run 
on the following gases only 

 

Nat Gas G20 @ 20mbar 8” W.G. 

 

PLEASE NOTE 

This conversion must be carried out by a Gas Safe Registered Engineer.

 

 

This conversion kit includes 

 

Description 

Product Code 

Quantity 

Hob valve bypass 
screw 

NAT GAS Hob valve bypass screw 
stamped with 85 

COPBPS - 85 

Hob burner 
injector 

NAT GAS Hob Burner Injector 
stamped with 185 

HOBINJECT185 

Oven valve 
bypass screw 

NAT GAS Oven valve bypass 
screw stamped with 70 

COPBPS - 70 

Oven burner 
injector 

NAT GAS oven burner injector 
stamped with 220 

INJECT220 

Labels 

 

NAT. GAS ONLY  

Instructions 

 

CONVIN44-1 

 

 

 

Содержание GB6

Страница 1: ...Instruction Manual Gas Oven GB6 GB6P ...

Страница 2: ......

Страница 3: ...Instructions 9 Fault Finding 10 Replacement Parts 11 Natural Gas Conversion Instructions 12 LPG Gas Conversion Instructions 13 Conversion Procedure 14 16 Technical Information 17 Service Information 18 Exploded View 19 Parts List 20 21 Warranty Information 22 Disposal Recycling 23 Parry Catering Equipment Midlands Ltd Town End Road Draycott Derby DE72 3PT Sales Tel 01332 875544 Fax 01332 874455 ...

Страница 4: ...ast iron pan supports The units are easy to clean with vitreous enamel lining provided with castors fitted as standard two of which are braked Features GB6 GB6P Unpacked weight kg 150 150 Packed weight kg 170 170 Dimensions w x d x h mm 900 x 790 x 970 900 x 790 x 970 Warranty 2 years 2 years KW Natural KW Propane 40 1 n a n a 34 2 Input Gas Connection 3 4 BSP Male 3 4 BSP Male Gas Input Pressure ...

Страница 5: ...l commercial gas catering equipment is recommended to be mounted below an extraction canopy Please consult a ventilation engineer or refer to Guidelines DW172 to calculate the ventilation requirements for cooking areas containing different pieces of gas catering equipment Each appliance requires a flow of fresh air for combustion Under no circumstances should air vents on the appliances or air ven...

Страница 6: ...cal fire regulations should be observed It is recommended that the appliance be sited below a ventilating hood preferably of the extractor type incorporating a grease filter The cooker is manufactured with four castors two of which are braked Caution should be taken when manipulating or moving the unit The appliance should be attached to a wall with a chain to restrict the movement of the unit onc...

Страница 7: ... removed from panels etc prior to commissioning the appliance All gas appliances must be fitted by a competent person to gas safety regulations in force Gas hoses used to connect the appliance to the gas supply must be of the correct specification for the gas and pressure of the appliance The gas hose must comply with the national requirements in force and be CE marked of a metal braided construct...

Страница 8: ...w on full gas to turn gas down turn knob anti clockwise this is the lowest setting which is factory set 5 To turn burners off turn knob clockwise all the way round Parry recommends that the hob is used only with pans that have a minimum diameter of 120mm and up to a maximum of 295mm diameter This ensures that there is satisfactory combustion and the pan is stable as it sits on the finger of the pa...

Страница 9: ...ed regularly to prevent build up of fat and grease There are three shelf positions in the oven the following guide is only intended as a guide to temperature in the centre of the oven It is strongly recommended that the user makes note of best results temperatures can vary as much as 20 c hotter at top of oven and 30 c cooler at the bottom of the oven These temperatures are measured in an empty ov...

Страница 10: ...wn the unit using hot soapy ware and a soft cloth do not use abrasive materials The wire shelves and the vitreous enamel bottom tray can be removed for cleaning but the lower tray must be in position when the appliance is in use Stainless steel cleaners maybe used and cleaning instructions on the product must be adhered to Never clean the unit with water jets ...

Страница 11: ...ervice must only be undertaken by a qualified electrician Parry Catering provides a complete after sales service by offering the sales of spare parts directly to customers Buying spares straight from the manufacturer allows customer to experience exceptional value and speedy delivery on all spare parts For more information on buying spares visit www parry co uk parry commercial catering spares ...

Страница 12: ...y alight Faulty connection at thermocouple valve incorrectly located Remake connection reposition thermocouple Burner goes out when turned to low Blockage in tap Clean and re grease Irregular flame Burner ring cap not correctly located or low pressure Relocate and check pressure at test point OVEN Failure to ignite Dirt or grease broken or loose connection Clean reconnect replace H T Lead Incorrec...

Страница 13: ...n burner mounting channel Assemble in reverse order OVEN THERMOSTAT Proceed as for hob tap Slide thermostat phial from housing inside oven Remove through hole in the top of the oven on right hand side Assemble in reverse order OVEN THERMOCOUPLE Remove the bottom oven tray Inside the oven disconnect the thermocouple from the extension piece Undo locknut holding thermocouple to oven burner Assemble ...

Страница 14: ...wing gases only Nat Gas G20 20mbar 8 W G PLEASE NOTE This conversion must be carried out by a Gas Safe Registered Engineer This conversion kit includes Description Product Code Quantity Hob valve bypass screw NAT GAS Hob valve bypass screw stamped with 85 COPBPS 85 6 Hob burner injector NAT GAS Hob Burner Injector stamped with 185 HOBINJECT185 6 Oven valve bypass screw NAT GAS Oven valve bypass sc...

Страница 15: ...ations enforced to run on the following gases only Propane G31 37mbar 14 8 W G PLEASE NOTE This conversion must be carried out by a Gas Safe Registered Engineer This conversion kit includes Description Product Code Quantity Hob valve bypass screw LPG hob valve bypass screw stamped 50 COPBPS 50 6 Hob burner injector LPG hob burner injector stamped 105 HOBINJECT105 6 LPG oven valve bypass screw stam...

Страница 16: ...appliance is isolated from the gas supply before commencing conversion Remove pan support and burner caps aluminium discs Remove the solid top plates Using a 10mm spanner or nut runner remove burner injector Replace with injector from conversion kit Replace solid top plates aluminium burner plates and burner caps ...

Страница 17: ...ll fascia away from the bottom Disconnect HT lead from piezo Remove low rate screws in hob tap bodies and replace with low rate screw from the conversion kit Replace low rate screw in oven thermostat body from the conversion kit Converting the oven burner Remove shelves and bottom tray Unscrew the 15mm nut on the jet that goes into the burner Unwind anti clockwise the jet out of the burner ...

Страница 18: ...required gas Refit gas pipe and tighten up the 15mm nut Connect the unit back to the gas supply and test for gas soundness Replace the facia and knobs accordingly When comversion is complete addix new data label and gas type label supplied with the conversion kit detailing type of gas and pressure ...

Страница 19: ... PRESSURE TOTAL HEAT INPUT NATURAL G20 20mb 8 W G 6 804 KW 23215 Btu h PROPANE G31 37mb 14 8 W G 8 140 KW 27774 Btu h GAS RATE M HR FT HR LB HR KG HR NATURAL G20 0 720 M HR 25 427 FT HR PROPANE G31 0 333 M HR 11 760 FT HR 1 292 LB HR 0 586 KG HR Total Unit BURNER LOW RATE FLOWRATE HEAT INPUT NATURAL G20 0 758 M HR 7 070 KW PROPANE G31 0 175 M HR 4 200 KW GAS OPERATING PRESSURE TOTAL HEAT INPUT NAT...

Страница 20: ...d person Enhanced 2 Years Warranty Parry Catering Midlands Ltd offer an enhanced warranty of two years including parts and labour on all of the Parry manufactured products To take advantage of this you should register you warranty by logging onto the company website and filling out our simple form www parry co uk the parry warranty If you have any issues with your product and wish to request a war...

Страница 21: ...Parry British Built for Purpose IN258 3 19 Exploded View ...

Страница 22: ...ode 13 Top Cover No Code 14 Middle Cover No Code 15 Pan Support CASTP6BO 16 Flue Cover No Code 17 Hob Burner Complete with Injector Carriage BURNRHOB 18 Hob Injector Nat Hob Injector LPG HOBINJECT185 HOBINJECT105 19 Injector Carriage Plate No Code 20 Saddle Bracket SADDLEBKT 21 Hob Gas Valve GASTAPHOB 21a Hob Bypass Screw Nat Hob Bypass Screw LPG COPBPS 70 COPBPS 50 22 Oven Valve OVENVALVE 22a Ove...

Страница 23: ...Keep LCPDOORKEEP 31 Ball Catch Assembly 32 Flexi Tube 200mm FLEXT200X8 33 Flexi Tube 500mm FLEXT500X8 34 75mm Swivel Castor CASTOR75SW 35 Chassis No Code 35a Leg Plate LEGPLATE 36 Oven Gas Pipe OVENPIPE1 37 75mm Swivel Braked Castor CASTOR75BR 38 Top RH Hinge ULT6BOHINGETR 39 Bottom RH Hinge ULT6BOHINGEBR 40 RH Door 41 Piezo Link Lead GB6PPIEZO Adjuster Boss for Castors ADJM12 Door Seal SEALPGS10 ...

Страница 24: ...allation date of the equipment To be eligible for a 2 year warranty products must be serviced at least once within the first 12 months of purchase All service calls will be carried out between 8am and 5pm Monday to Friday Your warranty is invalid if your equipment has not been installed in accordance with the manufacturer s instructions The misuse alteration or unauthorised repairs of the equipmen...

Страница 25: ...Parry British Built for Purpose IN258 3 23 Disposal Recycling The packaging should be disposed of according to regulations in force ...

Отзывы: