Parry
-British Built for Purpose
IN258-3
12
Natural Gas – Conversion Instructions
Product
GB6 – 6 Burner Oven LPG
For use with models with the following serial numbers
Model
From
To
GB6P
These instructions can be used for converting from LPG to Natural Gas
LPG units are designed and tested in accordance with all current regulations enforced to run
on the following gases only
Nat Gas G20 @ 20mbar 8” W.G.
PLEASE NOTE
This conversion must be carried out by a Gas Safe Registered Engineer.
This conversion kit includes
Description
Product Code
Quantity
Hob valve bypass
screw
NAT GAS Hob valve bypass screw
stamped with 85
COPBPS - 85
6
Hob burner
injector
NAT GAS Hob Burner Injector
stamped with 185
HOBINJECT185
6
Oven valve
bypass screw
NAT GAS Oven valve bypass
screw stamped with 70
COPBPS - 70
1
Oven burner
injector
NAT GAS oven burner injector
stamped with 220
INJECT220
1
Labels
NAT. GAS ONLY
1
Instructions
CONVIN44-1
1