Parry
-British Built for Purpose
IN258-3
17
Technical Information
Per Hob Burner
GAS
OPERATING PRESSURE
TOTAL HEAT INPUT
NATURAL G20
20mb / 8” W.G.
5.557 KW = 18959 Btu/h
PROPANE G31
37mb / 14.8” W.G.
4.351 KW = 14846 Btu/h
GAS RATE
M³/HR
FT³/HR
LB/HR
KG/HR
NATURAL G20
0.588 M³/HR
20.765 FT³/HR
PROPANE G31
0.178 M³/HR
6.286 FT³/HR
0.691 LB/HR
0.313 KG/HR
BURNER LOW RATE
FLOWRATE
HEAT INPUT
NATURAL G20
0.126
M³/HR
1.176 KW
PROPANE G31
0.029
M³/HR
0.700 KW
Per Oven Burner
GAS
OPERATING PRESSURE
TOTAL HEAT INPUT
NATURAL G20
20mb / 8” W.G.
6.804 KW = 23215 Btu/h
PROPANE G31
37mb / 14.8” W.G.
8.140 KW = 27774 Btu/h
GAS RATE
M³/HR
FT³/HR
LB/HR
KG/HR
NATURAL G20
0.720 M³/HR
25.427 FT³/HR
PROPANE G31
0.333 M³/HR
11.760 FT³/HR
1.292 LB/HR
0.586 KG/HR
Total Unit
BURNER LOW RATE
FLOWRATE
HEAT INPUT
NATURAL G20
0.758
M³/HR
7.070 KW
PROPANE G31
0.175
M³/HR
4.200 KW
GAS
OPERATING PRESSURE
TOTAL HEAT INPUT
NATURAL G20
20mb / 8” W.G.
40.144 KW = 136970 Btu/h
PROPANE G31
37mb / 14.8” W.G.
34.173 KW = 116599 Btu/h
GAS RATE
M³/HR
FT³/HR
LB/HR
KG/HR
NATURAL G20
4.248 M³/HR
150.017 FT³/HR
PROPANE G31
1.398 M³/HR
49.370 FT³/HR
5.425 LB/HR
2.460 KG/HR
AIR FLOW RATE FOR COMBUSTION
20m³/HR
44.52 FT³/HR
Содержание GB6
Страница 1: ...Instruction Manual Gas Oven GB6 GB6P ...
Страница 2: ......
Страница 21: ...Parry British Built for Purpose IN258 3 19 Exploded View ...