background image

  

 

Parry

-British Built for Purpose 

IN268-2

 

  

Product Overview

 

 
 

 
 
The AG4H/AG4HP models are perfect for high volume catering, the Parry four-burner gas 
hobs are powerful and reliable. The precise adjustable thermostat controls make them 
responsive and precise while the high quality stainless steel construction ensures the units 
are both robust and easy to clean.  
 

 
 

 

 
 
 
 
 

 

 

Содержание AG4H

Страница 1: ...Instruction Manual AG4H AG4HP 4 Burner Gas Boiling Hob ...

Страница 2: ......

Страница 3: ...aintenance Instructions 8 Replacement Parts 9 Fault Finding 10 NAT Gas Conversion Instructions 11 LPG Gas Conversion Instructions 12 Conversion Procedure 13 14 Technical Information 15 Technical Information 16 Exploded View 17 Parts List 18 Warranty Information 19 20 Disposal Recycling 21 Parry Catering Equipment Midlands Ltd Town End Road Draycott Derby DE72 3PT Sales Tel 01332 875544 ...

Страница 4: ...dels are perfect for high volume catering the Parry four burner gas hobs are powerful and reliable The precise adjustable thermostat controls make them responsive and precise while the high quality stainless steel construction ensures the units are both robust and easy to clean ...

Страница 5: ...W Propane Butane 22 2 n a n a 17 4 BTU Natural BTU Propane Butane 75 746 n a n a 59 369 Input Gas Connection BSP Male BSP Male GAS INPUT PRESSURE Natural GAS INPUT PRESSURE Propane GAS INPUT PRESSURE Propane Butane 20mbar n a n a n a 37mbar n a Can be converted using conversion kit Yes Yes It leads the industry in Design and aesthetic appeal Performance Power Functionality After sales support ...

Страница 6: ...nd the Health and Safety at Work Act All commercial gas catering equipment is recommended to be mounted below an extraction canopy Please consult a ventilation engineer or refer to Guidelines DW172 to calculate the ventilation requirements for cooking areas containing different pieces of gas catering equipment Each appliance requires a flow of fresh air for combustion Under no circumstances should...

Страница 7: ...rear of appliance This should not be blocked at any time This appliance should be installed with sufficient ventilation to prevent the occurrence of unacceptable concentrations of substances harmful to health in the room in which it is installed POSITIONING The appliance must not be installed on or against combustible surfaces minimum clearances must be Rear 150mm 6 Sides 150mm 6 Hotplate to combu...

Страница 8: ...in force and be CE marked of a metal braided construction suitable for commercial catering equipment The hoses should be periodically examined and replaced as necessary The tube or hose shall be fitted such that there are no sharp bends or torsional strain which may cause damage or failure of the tube or hose especially near the end fittings Torsional strain can be prevented by the use of internal...

Страница 9: ... up to a maximum of 295mm diameter This ensures that there is satisfactory combustion and the pan is stable as it sits on the finger of the pan support We advise these appliances should not be left unattended while switched on These appliances are for professional use by qualified people only There are no user serviceable parts It is recommended that the sealed top plate is cleaned regularly to pr...

Страница 10: ... clean all burner and flame retention ports Using a combination of brushes remove dust and lint from within the primary air ports venture and burners Check the burner aeration to ensure it is clear of debris Clean burner injectors ensuring orifices are not enlarged or damaged Stiff gas controls can in some instances be greased Please ensure the correct type or grease is used Check any ignition ele...

Страница 11: ...uying spares visit www parry co uk parry commercial catering spares For Gas Safe Engineers only HOB TAP Remove pan supports and pull off control knobs and unclip fascia panel Disconnect burner supply tube and thermocouple Undo the 2 screws securing the tap to the rail Check sealing washer and replace if necessary Assemble in reverse order HOB BURNER THERMOCOUPLE Remove Pan Supports and Burner caps...

Страница 12: ...y corroded blocked Check adjust burner pressure Check clean injector Check ventilation Check clean burner and replace as necessary Burners will not stay alight Faulty connection at thermocouple valve incorrectly located Remake connection reposition thermocouple Burner goes out when turned to low Blockage in tap Clean and re grease Irregular flame Burner ring cap not correctly located or low pressu...

Страница 13: ...urrent regulations enforced to run on the following gases only Nat Gas G20 20mbar 8 W G PLEASE NOTE This conversion must be carried out by a Gas Safe Registered Engineer This conversion kit includes Description Product Code Quantity Hob valve bypass screw NAT GAS Hob valve bypass screw stamped with 85 COPBPS 85 4 Hob burner injector NAT GAS Hob Burner Injector stamped with 185 HOBINJECT185 4 Label...

Страница 14: ...ith all current regulations enforced to run on the following gases only Propane G31 37mbar 14 8 W G PLEASE NOTE This conversion must be carried out by a Gas Safe Registered Engineer This conversion kit includes Description Product Code Quantity Hob valve bypass screw LPG hob valve bypass screw stamped 50 COPBPS 50 4 Hob burner injector LPG hob burner injector stamped 105 HOBINJECT105 4 Labels G31 ...

Страница 15: ...supply before commencing conversion Remove pan supports and burner caps Lift off aluminium burner plates Remove the cover plate and solid top plates Using an 10mm spanner remove burner injector Replace with injector from conversion kit Replace solid top plate aluminium burner plates and burner caps Remove the tap knobs to allow the fascia to unclip ...

Страница 16: ...dy and replace with low rate screw from the conversion kit Connect the unit back to the gas supply Test for gas soundness Replace the facia and knobs accordingly When conversion is complete addix new data label and gas type label supplied with the conversion kit detailing type of gas and pressure ...

Страница 17: ... HR BURNER LOW RATE FLOWRATE HEAT INPUT NATURAL G20 0 126 M HR 1 176 KW PROPANE G31 0 029 M HR 0 700 KW Total Unit GAS OPERATING PRESSURE TOTAL HEAT INPUT NATURAL G20 20mb 8 W G 22 226 KW 75836Btu h PROPANE G31 37mb 14 8 W G 17 404 KW 59384 Btu h GAS RATE M HR FT HR LB HR KG HR NATURAL G20 2 352 M HR 83 060 FT HR PROPANE G31 0 712 M HR 25 144 FT HR 2 763 LB HR 1 253 KG HR AIR FLOW RATE FOR COMBUST...

Страница 18: ...d person Enhanced 2 Years Warranty Parry Catering Midlands Ltd offer an enhanced warranty of two years including parts and labour on all of the Parry manufactured products To take advantage of this you should register you warranty by logging onto the company website and filling out our simple form www parry co uk the parry warranty If you have any issues with your product and wish to request a war...

Страница 19: ...Parry British Built for Purpose IN268 2 17 Exploded View ...

Страница 20: ...2 7 320MM Thermocouple 2 x M8X1 Locknuts THCP320ISP 2 8 Nat NAT GAS 09920909 C BP COPBPS 85 4 8 LPG CPB 09902187 COPBPS 50 4 9 COPRECI M14 x 1 5 NUT COPM14NUT 4 10 GAS KNOB 5 16 DIA SHAFT ULYKNOB2 4 11 HOB GAS TAP PARAGON RANGE GASTAPHOB 4 12 GAS RAIL FOR AG4H AG4HP AG4HRAIL 1 13 Saddle 09707409 SADDLEBKT 10 14 Vinyl Round End Cap 26 mm ID 25mm Inside Height PASCAP26MM 1 15 AEM Injector Carriage p...

Страница 21: ...s at Parry s discretion whether to repair or replace the equipment The warranty only applies if the equipment has been used in a professional manner following the manufacturer s instructions and maintenance guidelines The warranty covers defects in the material and component failure only We are not liable for trading loss loss of perishable items water damage or loss due to injury or fire damage P...

Страница 22: ...lack of cleaning of the extraction canopy the part will be chargeable The equipment should be installed by a competent person The equipment installer needs to know the design performance and the capacity of the ventilation system so they can ensure adequate ventilation Failure to grant access for pre arranged service call Equipment that has been set up or used incorrectly e g dishwasher detergents...

Страница 23: ...Parry British Built for Purpose IN268 2 21 Disposal Recycling The packaging should be disposed of in accordance with the regulations in force ...

Отзывы: