8
Maintenance Instructions
MAINTENANCE AND SERVICE MUST ONLY BE UNDERTAKEN BY REGISTERED FITTERS.
PLEASE NOTE THE LOW RATE ADJUSTER ON THE UNIT HAS BEEN FACTORY SET AND
SHOULD NOT BE ADJUSTED UNLESS BY A QUALIFIED ENGINEER IN WHICH CASE THE LOW
RATE ADJUSTER SHOULD BE RE-SEALED.
Parry recommends that this unit is serviced at least every 6 months
As part of a full service we recommend the following checks are carried out.
Before any maintenance isolate the appliance from the gas supply
Examine and clean all burner and flame retention ports.
Using a combination of brushes, remove dust and lint from within the primary air
ports venture and burners. Check the burner aeration to ensure it is clear of
debris.
Clean burner injectors ensuring orifices are not enlarged or damaged.
Stiff gas controls can in some instances be greased. Please ensure the correct
type or grease is used.
Check any ignition electrodes and high tension leads where fitted. Clean and
adjust where necessary
Check Door seal for damage and condition.
(If Applicable)
Reconnect gas supply and test all disturbed gas connections for gas tightness
using a non-corrosive leak detection fluid.
Check the appliance burner operating pressure, heat input rating or where
necessary both.