![PARRY AG4H Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/parry/ag4h/ag4h_product-instructions_3794847012.webp)
Parry
-British Built for Purpose
IN268-2
10
Fault Finding
Fault
Check /Possible Cause
Solution
Incorrect flame picture, flame
lift or noisy burner
Incorrect burner pressure,
Blocked or partially blocked
injector.
Inadequate ventilation.
Burner faulty/corroded/blocked
Check/adjust burner pressure
Check /clean injector,
Check ventilation.
Check / clean burner and
replace as necessary.
Burners will not stay alight
Faulty connection at
thermocouple-valve, incorrectly
located
Remake connection, reposition
thermocouple
Burner goes out when turned
to “low”
Blockage in tap
Clean and re-grease
Irregular flame
Burner ring/cap not correctly
located, or low pressure
Relocate and check pressure at
test point.
Содержание AG4H
Страница 1: ...Instruction Manual AG4H AG4HP 4 Burner Gas Boiling Hob ...
Страница 2: ......