3.4 Installation
A - How to position the hood casing (filtering type)
•
Mount the 120/150 reduction fitting whenever the air discharge tube is 120. The diameter of the air
outlet pipe must not be less than 120mm.
•
Assemble the activated carbon filters (optional).
•
Fix the hood to the unit using the eight screws supplied (M 4x10 steel - M 4,2x30 wood) together with
the 4 screws for attachment to the panel.
B
- How to position the hood casing (spirating type)
•
Mount the 120/150 reduction fitting whenever the air
discharge tube is 120.
•
Apply the flexi pipe over the lip of the reduction connction
for external exhaust and fix it with a pipe tightening ring.
•
Disassemble the activated carbon filters (if already
assembled).
•
Drill a 260 x 495mm slot on the lower part of the casing.
•
Anchor the hood to the casing by means of the eight M 3,9
x 9,5 screws included in the supply.
•
Connect the scavening pipe to the outdoor duct and fix it
with a pipe-tightening ring.
5