manualshive.com logo in svg
background image

IPS2000 Mifare IC Card Parking System 

Entry/Exit Terminal - IENT209/IEXT209 

 

 

 

Version 4.0 

Issue  Date:  2014.01 

Installation Manual 

 

 

 

 

 

Содержание IENT209

Страница 1: ...IPS2000 Mifare IC Card Parking System Entry Exit Terminal IENT209 IEXT209 Version 4 0 Issue Date 2014 01 Installation Manual...

Страница 2: ...or configuration testing 13 2 2 Connect barrier gate to terminal 14 2 2 1 Terminal I O control board wiring contact points reference 14 2 2 2 Barrier gate wiring diagram for Parktron barrier AGT210 16...

Страница 3: ...inal software update 33 4 How to collection 34 4 1 How to copy log files 34 4 2 How to change terminal time zone 34 4 3 How to set exact terminal date time 35 4 4 Tips to use Unix editor tool vi 35 Re...

Страница 4: ...pre installed anchor bolts with nuts washers and two 2 metal bars come with the shipment onto a proper position 1 1 Shipping package Terminal cabinet is normally securely fastened by 4 big metal bolt...

Страница 5: ...ation island preparation 1 2 1 Suggested dimensions A cement foundation island for installing terminal and barrier is recommended with the suggested dimensions as 20cm H x 460cm L x 80cm W to ensure t...

Страница 6: ...cable to terminal only Standard CAT 5 with RJ45 connector Intercom wire to terminal only PVC 0 75 mm2 2C Control signal wire from terminal to barrier 22AWG 8C 1 2 3 Anchor bolts For a stronger streng...

Страница 7: ...arktron Technology Ltd Terminal Anchor bolts location reference Barrier Only for AGT210 barrier purchased from Parktron Anchor bolts location reference Two 2 metal fasten bars to secure terminal on to...

Страница 8: ...ion and wiring guide Maintain a 200cm minimum distance between 2 adjacent wire loops Maintain a 50cm minimum distance to any metal equipment from a wire loop Maintain a 100cm minimum distance to a sli...

Страница 9: ...tal objects or influenced by heavy power cables can try to use 8 shape loop wiring installation Refer to the following drawing 1 3 3 Ground slot cutting for loop wire installation Suggested ground slo...

Страница 10: ...wire loop turns required 3 4M 6 4 6M 5 6 10M 4 10 20M 3 20M above 2 Suggested slot depth and width Slot width 0 2cm 0 5cm Slot depth Normally about 3 5cm or can be calculated with the following formu...

Страница 11: ...umber of loop turns required 4 Place backer rods must be non metal material and roughly 30cm long with 2 5cm piece spaced in between every piece on top of the loop wires to hold them stay at the botto...

Страница 12: ...pre installed inside terminal cabinet refer to image below If not purchased from Parktron please verify your loop detectors are functional compatible with Parktron system 2 1 2 Loop wire connection t...

Страница 13: ...IP6 ON DIP7 OFF DIP8 ON Extend 20 SEC DIP6 OFF DIP7 ON DIP8 ON Extend 30 SEC DIP6 ON DIP7 ON DIP8 ON 7 OFF OFF 8 OFF OFF 9 OFF ON LOW frequency DIP9 ON DIP10 ON MED LOW frequency DIP9 OFF DIP10 ON MED...

Страница 14: ...test the remaining 3 frequencies on the second loop detector and select one best frequency for it Sensitivity adjustment Applying the adjustment to both loop detectors Suggested detection height sensi...

Страница 15: ...15 2014 2024 Parktron Technology Ltd If common point has 12 24V V make jumper middle pin short with BR_V Barrier control circuit CN2 CN4 CN3 CN7 CN6 JP2 CN5 CN1...

Страница 16: ...16 2014 2024 Parktron Technology Ltd 2 2 2 Barrier gate wiring diagram for Parktron barrier AGT210 For system with 110VAC power source...

Страница 17: ...17 2014 2024 Parktron Technology Ltd For system with 220VAC power source...

Страница 18: ...4V V Output signal type of barrier arm close position Relay output N C When barrier arm reach lowest close position N C Open Type 2 Barrier open close signal common 12V 24V V Output signal type of bar...

Страница 19: ...al type of barrier arm close position Active low When barrier arm reach lowest close position Down Position output signal 5V 24V 0V Type 4 Barrier open close signal common GND 0V Output signal type of...

Страница 20: ...arrier arm open position Active high When barrier arm reach highest open position Up Position output signal 0V 5V 24V Type 6 Barrier open close signal common GND 0V Output signal type of barrier arm c...

Страница 21: ...fer to the drawing in section 2 2 1 for CN5 location CN7 Signal inputs Refer to the drawing in section 2 2 1 for CN7 location CN number Connector Contact Name Function description CN7 A5 Spare input C...

Страница 22: ...n contact point for NC and NO L C NC Relay normal close L C NO Relay normal open CN3 CN3 FULL Providing a present signal output when parking full Signal stop when parking space available again CN3 CN3...

Страница 23: ...ng diagram example 2 4 2 Parktron intercom sub unit Intercom sub unit is installed on the face plate of a terminal It is compliant to AIPHONE LE room subs J2 TD SW Connect to intercom push button on t...

Страница 24: ...d by projects Parktron provides selection of the followings AIPHONE LEF 3 LEF 5 LEF 10 LEF 10S or any AIPHONE compatible intercom device should work at own purchase 2 5 Network cable connection 2 5 1...

Страница 25: ...ection 2 6 1 Terminal input power requirement Depends on local requirement Parktron supply two 2 voltages option 110 120VAC 6A 220 240VAC 3A 2 6 2 Input power connection location Connect input power w...

Страница 26: ...to a switch or hub that is on the same network with terminal Run putty exe and type in terminal IP address for connection Note Normally terminal configuration parameters and IP address have been pre c...

Страница 27: ...nter Userid parktron and Password pt12885568 to login 3 3 Configure terminal IP address With the command cd LocalSeting to change current working directory to LocalSeting directory Use vi to edit Host...

Страница 28: ...ct the terminal item 3 4 Specify terminal program for entry or exit Under LocalSeting file directory the filename location in makes the terminal program to run in entry mode When rename to location ou...

Страница 29: ...y and exit terminals on the system In case of losing a Parking ini in one terminal you can copy it from other terminal and use it Important Generally all terminal parameters in Parking ini configurati...

Страница 30: ...tegrated PlateServerPort UDP port number to communicate with License Plate Recognition program integrated Set 0 if LPR system is not integrated PlateTimeout Timeout setting for waiting LPR program rep...

Страница 31: ...f problem card ticket recycle bin PreTicket Pre issue card ticket to increase dispensing speed 1 Yes 0 no Loop2Timeout Timeout setting for closing barrier loop2 after car entered UpLayerID Used for mu...

Страница 32: ...onfigured there will be Location02 Location03 etc 3 7 Edit Machine SN Under LocalSeting file directory use vi to edit the number in file MachineSN It specifies which individual terminal parameter sect...

Страница 33: ...stem Rename the file reset off to reset on in the folder Data LocalSeting The terminal will reboot automatically in 20 seconds Note FileZilla free download URL http filezilla project org download php...

Страница 34: ...og of April 25th 2012 the filename is 20120425 log 4 2 How to change terminal time zone Terminal time zone is normally re configured according to shipping destination in Parktron factory Following the...

Страница 35: ...to terminal linux OS with Putty exe Login ID parktron Password pt12885568 Type command date mmddhhnnyyyy to change the exact date time on terminal ie Nov 6 14 58 2012 date 110614582012 4 4 Tips to us...

Отзывы: